AIR FLOW DATA
|
|
| HIGH / LOW SPEED COOLING AND HEAT PUMP CFM |
|
| ||||
060B12 |
|
|
| 080B12 |
| Jumper Settings | |||
High |
| Low |
| High |
| Low |
| COOL Tap | ADJ Tap* |
1343 |
| 865 |
| 1320 |
| 882 |
| A | B |
1116 |
| 727 |
| 1093 |
| 755 |
| B | B |
1235 |
| 791 |
| 1203 |
| 810 |
| A | A |
1026 |
| 661 |
| 1001 |
| 693 |
| B | A |
1079 |
| 709 |
| 1080 |
| 730 |
| A | C |
889 |
| 590 |
| 880 |
| 641 |
| C | B |
900 |
| 599 |
| 910 |
| 642 |
| B | C |
787 |
| 531 |
| 803 |
| 585 |
| D | B |
814 |
| 542 |
| 836 |
| 597 |
| C | A |
712 |
| 490 |
| 738 |
| 557 |
| D | A |
725 |
| 499 |
| 749 |
| 561 |
| C | C |
641 |
| 456 |
| 682 |
| 529 |
| D | C |
080C16 |
|
|
| 100C16 |
| Jumper Settings | |||
High |
| Low |
| High |
| Low |
| COOL Tap | ADJ Tap* |
1787 |
| 1171 |
| 1818 |
| 1192 |
| A | B |
1503 |
| 987 |
| 1545 |
| 1030 |
| B | B |
1620 |
| 1053 |
| 1661 |
| 1083 |
| A | A |
1405 |
| 914 |
| 1427 |
| 936 |
| B | A |
1462 |
| 964 |
| 1497 |
| 991 |
| A | C |
1217 |
| 785 |
| 1234 |
| 819 |
| C | B |
1245 |
| 818 |
| 1265 |
| 832 |
| B | C |
940 |
| 608 |
| 977 |
| 648 |
| D | B |
1091 |
| 702 |
| 1116 |
| 728 |
| C | A |
852 |
| 551 |
| 884 |
| 572 |
| D | A |
983 |
| 626 |
| 1019 |
| 666 |
| C | C |
764 |
| 544 |
| 791 |
| 519 |
| D | C |
100C20 |
|
|
| 120D20 |
| Jumper Settings | |||
High |
| Low |
| High |
| Low |
| COOL Tap | ADJ Tap* |
2019 |
| 1290 |
| 2006 |
| 1397 |
| A | B |
1790 |
| 1174 |
| 1687 |
| 1131 |
| B | B |
1818 |
| 1195 |
| 1845 |
| 1282 |
| A | A |
1630 |
| 1068 |
| 1552 |
| 1050 |
| B | A |
1649 |
| 1082 |
| 1694 |
| 1157 |
| A | C |
1269 |
| 848 |
| 1502 |
| 1011 |
| C | B |
1432 |
| 956 |
| 1400 |
| 944 |
| B | C |
1078 |
| 704 |
| 1365 |
| 922 |
| D | B |
1169 |
| 770 |
| 1364 |
| 931 |
| C | A |
986 |
| 638 |
| 1232 |
| 808 |
| D | A |
1062 |
| 685 |
| 1225 |
| 808 |
| C | C |
866 |
| 576 |
| 1117 |
| 718 |
| D | C |
|
|
|
| HIGH / LOW | HEAT CFM |
|
|
| |
060B12 |
|
|
| 80B12 |
| Jumper Settings | |||
High |
| Low |
| High |
| Low |
| HEAT Tap | ADJ Tap* |
1364 |
| 843 |
| 1433 |
| 945 |
| A | Any |
1253 |
| 745 |
| 1320 |
| 887 |
| B | Any |
1102 |
| 660 |
| 1223 |
| 840 |
| C | Any |
1014 |
| 607 |
| 1134 |
| 768 |
| D | Any |
80C16 |
|
|
| 100C16 |
| Jumper Settings | |||
High |
| Low |
| High |
| Low |
| HEAT Tap | ADJ Tap* |
1684 |
| 1095 |
| 1795 |
| 1171 |
| A | Any |
1542 |
| 1011 |
| 1585 |
| 1047 |
| B | Any |
1426 |
| 927 |
| 1420 |
| 929 |
| C | Any |
1289 |
| 832 |
| 1201 |
| 785 |
| D | Any |
100C20 |
|
|
| 120D20 |
| Jumper Settings | |||
High |
| Low |
| High |
| Low |
| HEAT Tap | ADJ Tap* |
2194 |
| 1417 |
| 1937 |
| 1323 |
| A | Any |
1999 |
| 1290 |
| 1757 |
| 1199 |
| B | Any |
1799 |
| 1182 |
| 1594 |
| 1062 |
| C | Any |
1614 |
| 1062 |
| 1429 |
| 957 |
| D | Any |
All CFM’s are shown at 0.5” | w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. | ||||||||
static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static | |||||||||
pressure is not recommended. |
|
|
|
|
|
|
|
| |
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air clean- | |||||||||
ers. Consult the instructions for the electronic air cleaner for further details. |
|
|
|
|
| ||||
* The ADJ “D” tap should not be used. |
|
|
|
|
|
|
|
| |
Subject to change without notice. Printed in U.S.A. |
|
|
|
| |||||