York LY8S*UH, GY8S*UH Cabinet and Duct Dimensions, Models, Cfm, Cabinet Cabinet Dimension Size

Page 2

278436-YTG-A-0407

B

3/4

40

A

FRONT

 

 

4” Diameter

 

 

20

 

(VENT CONNECTIONS)

 

 

 

 

POWER WIRING

 

 

 

 

7/8” HOLE

 

 

13-3/4

 

 

14-3/4

 

 

 

2-1/2

5-3/8

 

 

 

 

 

 

 

32-1/2

 

 

GAS INLET

 

 

 

 

1-1/4 x 2-1/2

 

ACCESS

 

 

 

 

WIRING

2

 

 

 

7/8” K.O.

 

 

 

 

 

14

 

 

 

16

 

 

 

 

 

23-1/2

2-1/4

 

 

8-3/4

 

1-1/8

 

 

 

 

28-1/2

 

 

 

 

LEFT SIDE

 

T’STAT WIRING 7/8” K.O.

RIGHT SIDE

 

 

 

 

 

 

 

 

1-1/2

 

 

5/8

 

 

 

 

 

26-1/2

1-1/4

20

5/8

 

C

D

B

4” Diameter

BOTTOM IMAGE

RETURN END

24-3/4

TOP IMAGE

SUPPLY END

CABINET AND DUCT DIMENSIONS

Models

CFM

Cabinet

 

Cabinet Dimension

 

Size

A

B

C

D

 

 

 

 

 

 

 

 

 

(G,L)Y8S040A12UH11

1200

A

14 1/2

13 1/4

11 1/2

10 1/8

 

 

 

 

 

 

 

(G,L)Y8S060A12UH11

1200

A

14 1/2

13 1/4

11 1/2

10 1/8

 

 

 

 

 

 

 

(G,L)Y8S080A12UH11

1200

A

14 1/2

13 1/4

11 1/2

10 1/8

 

 

 

 

 

 

 

(G,L)Y8S080B16UH11

1600

B

17 1/2

16 1/4

14 1/2

11 5/8

 

 

 

 

 

 

 

(G,L)Y8S080C16UH11

1600

C

21

19 3/4

18

13 3/8

 

 

 

 

 

 

 

GY8S080C22UH11

2200

C

21

19 3/4

18

13 3/8

LY8S080C20UH11

2000

 

 

 

 

 

 

 

 

 

 

 

 

(G,L)Y8S100B12UH11

1200

B

17 1/2

16 1/4

14 1/2

11 5/8

 

 

 

 

 

 

 

(G,L)Y8S100B16UH11

1600

B

17 1/2

16 1/4

14 1/2

11 5/8

 

 

 

 

 

 

 

(G,L)Y8S100C16UH11

1600

C

21

19 3/4

18

13 3/8

 

 

 

 

 

 

 

(G,L)Y8S100C20UH11

2000

C

21

19 3/4

18

13 3/8

 

 

 

 

 

 

 

GY8S115C16UH11

1600

C

21

19 3/4

18

13 3/8

 

 

 

 

 

 

 

(G,L)Y8S115C20UH11

2000

C

21

19 3/4

18

13 3/8

 

 

 

 

 

 

 

(G,L)Y8S130D20UH11

2000

D

24 1/2

23 1/4

21 1/2

15 1/8

 

 

 

 

 

 

 

2

Unitary Products Group

Image 2
Contents Description WarrantyFeatures Natural GASModels Cabinet and Duct DimensionsCabinet Cabinet Dimension Size CFMAfue Ratings & Physical / Electrical Data Upflow ModelsInput Output Nominal Cabinet Total Unit Air Temp Models InputBlower Performance CFM Upflow Without Filter Bottom Return Bottom Airflow Data ScfmLeft Side Airflow Data Scfm Models Recommended Filter Sizes Horizontal Sidewall VentingFilter Performance Filter Performance Pressure Drop Inches W.C. and KPAAC1 GroupAccessories Applying Filter Pressure Drop to Determine System Airflow