HP Data Center EnvIronmental Edge manual Zone Overview controls, Zone Overview legend

Page 22

Callout Description

you to change the details that appear.

5The Refresh button enables you to refresh the view at any time to show current and updated information.

The zone Overview controls

These controls consist of a row of buttons at the upper right corner of the zone Overview tab which provides the user with additional ways to change the appearance of items on this page and a quick way to navigate.

Button

Icon

Description

 

 

 

Show/Hide Legend

 

Enables the user to either show or hide the

 

 

Legend window

 

 

 

Filter Visible

 

Enables the user to either show or hide any

Objects

 

object type (base station, CRAH/CRAC,

 

 

rack, or power meter) in the zone Overview

 

 

 

Change Zoom Level

 

Enables the user to zoom in to detailed

 

 

areas of the Overview or zoom out to see

 

 

the entire Overview

 

 

 

Show/Hide Locater

 

Enables the user to locate the smaller area

View

 

they are viewing within a large data center.

 

 

 

The zone Overview legend

The Legend window provides an explanation about all the icons that appear in the zone Overview.

The color of the icons that appear in the zone Overview also relay the device status:

Green—The device does not have any active alerts associated to it.

Yellow—The device is either not communicating or it has an invalid configuration.

Red—The device has active alerts.

Filtering visible objects

1.In the upper right corner of the zone Overview, select the Filter Visible Objects icon.

Views 22

Image 22
Contents HP Insight Environmental Observer Software User Guide Part Number December 2010 Fourth EditionIntended audience Contents 103 100102 104System requirements About HP Insight Environmental ObserverComponents Hardware requirementsClient PC requirements Accessing the HP Insight Environmental ObserverSoftware requirements Software RequirementsSecure web access Interface components Callout Component DescriptionMenu bars Navigation panelSetting permissions HP Insight Environmental Observer console interface Data View window Global Information panelSorting the data in a column Changing the appearance of columnsSystem status Resizing the width of a columnClosing the Data View window Printing dataResizing the Data View window Hiding a columnData center views PUE tabAccessing the PUE tab Viewing data center PUE informationAdjusting chart and graph options Views To adjust the axis line, see The base station toolbar on Accessing the Overview tabOverview tab Viewing data center Overview information Viewing zone Overview information Filtering visible objects Zone Overview controlsZone Overview legend Callout DescriptionLocator view Viewing configuration details for individual components Viewing data values Base station toolbar Sensor object Icon Description CRAH/CRACViews Detecting disconnected sensors Imaging tab Detecting sensors that require maintenanceAccessing the Imaging tab Icon Status and meaning LocationSensor types and date ranges of data to show Display modes Map LegendViewing static information Sensor-type Description Views Viewing animated information Accessing the Pre-Defined Metrics tab Pre-Defined Metrics tabPre-defined metric definitions Metric Affected objects DescriptionAccessing the Custom Metrics tab Custom Metrics tabViews Views Tabular views Accessing the Tabular viewsSelect Refresh at anytime to update the data and graph Sensor object tabsCRAH/CRAC tab Column DescriptionRacks tab Pressure tab Power Meters tab Views Views Views Base Station tab Alerts Active Alerts tab Exporting tabular data to a .csv file Alert History tabWireless Sensor Network tab Accessing the wireless sensor networkVirtual map Shows the wireless device location on Menu bar actions Menu bar optionsReports menu Creating a reportSingle-click a zone to view the properties for that zone Menu bar actions Menu bar actions Menu bar actions Analyzing data Creating custom reports Saving the reportViewing custom queries Editing custom queries Running custom queriesDeleting custom queries Generating battery reports Base Station F/W reports Exporting report data to .csv file Viewing sensor data for analysisAlerts menu Customizing chartsSelect Save to save the data comparison Viewing global active alerts Viewing global alert historyDefining a new alert Create a condition Object Values available CracManaging alerts Performing alert actions Creating an alert definition AuditPredefined alert Description Editing an existing alert definition Menu bar actions Menu bar actions Activating an existing alert definition Deactivating an existing alert definition Deleting individual alerts Administration menu Deleting all alerts from databaseCreating user accounts Create Account User Accounts System Log OptionsUser accounts Searching for user accountsChanging user passwords Clearing active alerts associated with a user Editing or deleting usersViewing the system log Administrative options Auditors options Email optionsSecurity Imaging Alerts Snmp options Menu bar actions Security options Menu bar actions Imaging options Alerts options Changing your password My Account menuChanging your preferences Changing the general preferencesChanging the data display format Changing the language Changing the date formatFrom the Preferences menu, select Language Viewing version information Accessing the user guideHelp menu Help menu offers the following options User Guide AboutMenu bar actions Maintenance Battery managementReplacing batteries System backup System restore MySQL databaseHP Insight Environmental software troubleshooting Problem SolutionInsight Environmental Configurator User Guide , respectfully Before you contact HP HP contact informationBranch circuit monitoring system Cold top inlet air temperature rate of changeData access layer Identification Internet Protocol Bypass air flowRandom access memory Power Distribution, IncorporatedPower usage efficiency Recirculation air flow Rack Cooling IndexIndex Index Index
Related manuals
Manual 19 pages 31.27 Kb

Data Center EnvIronmental Edge specifications

HP Data Center Environmental Edge is a cutting-edge solution designed to optimize the efficiency and sustainability of data center operations. In an era where data centers consume enormous power and generate significant carbon footprints, HP's Environmental Edge provides an innovative approach to managing these challenges.

One of the main features of the Environmental Edge is its advanced cooling solutions. Traditional cooling systems often operate inefficiently, leading to wasted energy and excessive costs. HP's system incorporates smart cooling technologies that adapt to the specific thermal demands of each data center room. By utilizing a combination of hot aisle/cold aisle containment and dynamic airflow management, the Environmental Edge ensures that cold air is effectively directed where it’s needed most, significantly reducing the amount of energy required to maintain optimal temperatures.

Another key characteristic of the HP Data Center Environmental Edge is its integration with IoT (Internet of Things) technologies. The solution employs a network of sensors that continuously monitor environmental conditions, including temperature, humidity, and air quality. This data is processed in real-time to provide actionable insights, allowing data center operators to make informed decisions regarding energy use and equipment deployment.

HP’s Environmental Edge also emphasizes modularity and scalability. As business needs evolve, data centers require flexible solutions that can grow with them. HP's approach incorporates modular components that can be easily integrated or upgraded, allowing businesses to expand their infrastructure without significant overhauls. This adaptability not only lowers upfront costs but also reduces waste, making it a more sustainable choice for organizations committed to environmental responsibility.

Sustainability is further enhanced through HP’s commitment to energy efficiency. The Environmental Edge utilizes advanced energy management software that calculates power consumption in real-time. This ensures that resources are used efficiently and helps organizations meet their green energy targets. Additionally, the system promotes the use of renewable energy sources, allowing data centers to minimize their reliance on fossil fuels.

In summary, the HP Data Center Environmental Edge stands out with its innovative cooling solutions, integration of IoT technologies, modular design, and energy efficiency initiatives. These features work together to create an intelligent, adaptive, and sustainable environment for data centers, addressing the pressing need for eco-friendly practices in the tech industry. As organizations navigate the complexities of modern data management, HP's Environmental Edge provides the tools needed to thrive in both performance and sustainability.