York 1-1/2 THRU 5 TON (10 SEER) installation instructions Champion Series, General, Inspection

Page 1
CHAMPION® SERIES

J

CHAMPION® SERIES

 

 

SINGLE PACKAGE AIR CONDITIONERS

 

ELECTRIC/ELECTRIC, AIR-COOLED

INSTALLATION INSTRUCTION Supersedes: 035-16703-000-A-0701

035-16703-001-A-0202

MODELS D1EB018 THRU 060

1-1/2 THRU 5 TON

(10 SEER)

GENERAL

Model D1EB units are factory assembled cooling only air condi- tioners designed for outdoor installation on a rooftop or a slab. Field-installed electric heater accessories are available to provide electric heat combined with electric cooling. All units and heaters are certified by AGA and CGA.

The units are completely assembled on rigid, but easily remov- able base rails. All piping, refrigerant charge, and electrical wir- ing is factory installed and tested. The units require only electric power and duct connections at the point of installation.

The electric heaters have nickel-chrome resistance wire ele- ments and utilize single point power connection.

INSPECTION

As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. Refer to Form 50.15-NM for additional information.

REFERENCE

Additional information on the design, installation, operation and service of this equipment is available in the following refer- ence forms:

55.70-N1 -General Installation

55.70-N2 -Pre-start & Post-start Check List

511.26-N1.1V -Electric Heater Accessory

REPLACEMENT PARTS

Refer to Replacement Parts Manual for complete listing of replacement parts on this equipment.

All forms referenced in this instruction may be ordered from:

Standard Register

Norman, OK 73069

Toll Free: Tel. 877-318-9675/Fax. 877-379-7920

Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not handled properly.

CAUTION

THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH

THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE

LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED

TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.

WARNING

INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY O R PRO PERTY DAM AG E .

Image 1
Contents CHAMPION SERIES REPLACEMENT PARTSSINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLEDLIMITATIONS INSTALLATIONTABLE 1 - UNIT APPLICATION DATA LOCATIONFILTERS SERVICE ACCESSCONDENSATE DRAIN THERMOSTATFIG. 2 - TYPICAL FIELD WIRING DIAGRAM POWER AND CONTROL WIRINGCONTROL WIRING POWER WIRINGTABLE 4 - ELECTRICAL DATA BASIC UNIT TABLE 5 - ELECTRICAL DATA COOLING / ELECTRIC HEAT ensureD1NA024Coil D1NA036Checking Supply Air CFM D1NA08035-16703-001-A-0202 OUTDOOR 1412 FIG. 3 - DIMENSIONS AND CLEARANCES2814 17142214Cooling SEQUENCE OF OPERATIONHeating NORMAL MAINTENANCE MAINTENANCEFC031SEEONTROL-09104DEDETFAILROST-000AC D/PCONFIGURATIONT1T2M1-2L2 S/OPCONFIGURATIOTIONALCCHNDETAILACOMPR CONTROLDEFROST CONTROLD E T A I L E L E M E N T A R Y D I A G R A MTYPICAL WIRING DIAGRAM NOTES TYPICAL WIRING DIAGRAM LEGEND5005 York Drive, Norman Oklahoma Unitary Products GroupSupersedes 035-16703-000-A-0701 035-16703-001-A-0202