York 1-1/2 THRU 5 TON (10 SEER), D1EB018 THRU 060 installation instructions Outdoor

Page 9

 

 

 

 

 

 

 

 

 

 

 

 

 

035-16703-001-A-0202

TABLE 10 - SUPERHEAT CHARGING TABLE FOR MODEL D1EB042

 

 

 

 

 

 

 

 

OUTDOOR

 

 

SUPERHEAT AT COMPRESSOR SUCTION (F), AIRFLOW = 1,400 CFM/TON

 

 

 

 

TEMPERATURE

 

 

 

 

 

INDOOR WB TEMPERATURE (F)

 

 

 

 

 

 

 

(F)

55

57

 

59

61

63

65

67

69

71

 

73

 

75

 

 

 

 

 

 

65

20.3

21.9

 

23.5

25.0

26.6

28.1

29.7

30.6

31.6

 

32.6

 

33.6

 

70

16.7

18.5

 

20.3

22.1

23.9

25.7

27.5

28.6

29.7

 

30.8

 

32.0

 

75

13.0

15.1

 

17.1

19.2

21.2

23.2

25.3

26.6

27.8

 

29.1

 

30.4

 

80

9.4

11.7

 

13.9

16.2

18.5

20.8

23.1

24.5

25.9

 

27.3

 

28.7

 

85

5.7

8.2

 

10.8

13.3

15.8

18.4

20.9

22.5

24.0

 

25.6

 

27.1

 

90

-

6.5

 

9.1

11.7

14.2

16.8

19.4

21.0

22.6

 

24.1

 

25.7

 

95

-

-

 

7.4

10.0

12.7

15.3

17.9

19.5

21.1

 

22.7

 

24.3

 

100

-

-

 

5.8

7.9

10.0

12.0

14.1

16.3

18.4

 

20.6

 

22.8

 

105

-

-

 

-

5.8

7.3

8.7

10.2

13.0

15.8

 

18.6

 

21.4

 

110

-

-

 

-

-

-

5.5

6.4

9.8

13.2

 

16.5

 

19.9

 

115

-

-

 

-

-

-

-

-

6.5

10.5

 

14.5

 

18.5

 

TABLE 11 - SUPERHEAT CHARGING TABLE FOR MODEL D1EB048

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

SUPERHEAT AT COMPRESSOR SUCTION (F), AIRFLOW = 1,600 CFM/TON

 

 

 

 

TEMPERATURE

 

 

 

 

 

INDOOR WB TEMPERATURE (F)

 

 

 

 

 

 

 

(F)

55

57

 

59

61

63

65

67

69

71

 

73

 

75

 

 

 

 

 

 

65

13.5

15.4

 

17.3

19.1

21.0

22.8

24.7

26.1

27.6

 

29.0

 

30.5

 

70

10.7

12.7

 

14.7

16.8

18.8

20.9

22.9

24.7

26.5

 

28.2

 

30.0

 

75

7.8

10.0

 

12.2

14.5

16.7

18.9

21.2

23.3

25.4

 

27.5

 

29.6

 

80

-

7.3

 

9.7

12.1

14.5

17.0

19.4

21.8

24.2

 

26.7

 

29.1

 

85

-

-

 

7.2

9.8

12.4

15.0

17.6

20.4

23.1

 

25.9

 

28.6

 

90

-

-

 

6.1

7.7

9.4

11.0

12.7

16.6

20.5

 

24.4

 

28.3

 

95

-

-

 

-

5.7

6.3

7.0

7.7

12.7

17.8

 

22.8

 

27.9

 

100

-

-

 

-

5.3

5.9

6.5

7.1

11.1

15.1

 

19.1

 

23.0

 

105

-

-

 

-

-

5.5

6.0

6.6

9.5

12.4

 

15.3

 

18.2

 

110

-

-

 

-

-

5.0

5.5

6.0

7.8

9.7

 

11.6

 

13.4

 

115

-

-

 

-

-

-

-

5.4

6.2

7.0

 

7.8

 

8.6

 

TABLE 12 - SUPERHEAT CHARGING TABLE FOR MODEL D1EB060

 

 

 

 

 

 

 

 

OUTDOOR

 

 

SUPERHEAT AT COMPRESSOR SUCTION (F), AIRFLOW = 2,000 CFM/TON

 

 

 

 

TEMPERATURE

 

 

 

 

 

INDOOR WB TEMPERATURE (F)

 

 

 

 

 

 

 

(F)

55

57

 

59

61

63

65

67

69

71

 

73

 

75

 

 

 

 

 

 

65

25.3

25.8

 

26.3

26.8

27.3

27.8

28.3

28.7

29.1

 

29.6

 

30.0

 

70

22.2

23.0

 

23.7

24.4

25.1

25.9

26.6

27.4

28.2

 

28.9

 

29.7

 

75

19.2

20.1

 

21.1

22.1

23.0

24.0

24.9

26.1

27.2

 

28.3

 

29.4

 

80

16.1

17.3

 

18.5

19.7

20.9

22.1

23.3

24.7

26.2

 

27.7

 

29.1

 

85

13.1

14.5

 

15.9

17.3

18.8

20.2

21.6

23.4

25.2

 

27.0

 

28.9

 

90

10.3

11.7

 

13.1

14.5

15.9

17.3

18.6

21.1

23.5

 

25.9

 

28.3

 

95

7.6

8.9

 

10.3

11.6

13.0

14.3

15.7

18.7

21.8

 

24.8

 

27.8

 

100

6.6

7.7

 

8.9

10.1

11.3

12.5

13.6

16.7

19.7

 

22.7

 

25.8

 

105

5.6

6.6

 

7.6

8.6

9.6

10.6

11.6

14.6

17.6

 

20.7

 

23.7

 

110

-

5.4

 

6.2

7.0

7.9

8.7

9.5

12.5

15.6

 

18.6

 

21.6

 

115

-

-

 

-

5.5

6.2

6.8

7.5

10.5

13.5

 

16.5

 

19.5

 

Unitary Products Group

9

Image 9
Contents CHAMPION SERIES REPLACEMENT PARTSSINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLEDLIMITATIONS INSTALLATIONTABLE 1 - UNIT APPLICATION DATA LOCATIONFILTERS SERVICE ACCESSCONDENSATE DRAIN THERMOSTATFIG. 2 - TYPICAL FIELD WIRING DIAGRAM POWER AND CONTROL WIRINGCONTROL WIRING POWER WIRINGTABLE 4 - ELECTRICAL DATA BASIC UNIT TABLE 5 - ELECTRICAL DATA COOLING / ELECTRIC HEAT ensureD1NA024Coil D1NA036Checking Supply Air CFM D1NA08035-16703-001-A-0202 OUTDOOR 1412 FIG. 3 - DIMENSIONS AND CLEARANCES2814 17142214SEQUENCE OF OPERATION CoolingHeating NORMAL MAINTENANCE MAINTENANCEFC031SEEONTROL-09104DEDETFAILROST-000AC D/PCONFIGURATIONT1T2M1-2L2 S/OPCONFIGURATIOTIONALCCHNDETAILACOMPR CONTROLDEFROST CONTROLD E T A I L E L E M E N T A R Y D I A G R A MTYPICAL WIRING DIAGRAM NOTES TYPICAL WIRING DIAGRAM LEGEND5005 York Drive, Norman Oklahoma Unitary Products GroupSupersedes 035-16703-000-A-0701 035-16703-001-A-0202