COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT |
| AIR HANDLER |
|
|
|
| COOLING |
|
| |
|
| ELECTRIC |
| COIL MODEL1 | RATED | NET MBH |
|
| ||
MODEL | MODEL |
| W | SEER | EER | |||||
| HEAT KW2 |
| CFM |
|
| |||||
|
| TOTAL | SENS. | |||||||
|
|
|
|
|
|
| ||||
|
|
| 1 PH 13 SEER AC WITH AHP/ SHP / F*FP |
|
|
|
| |||
| AHP18 |
| 2,5,8 | 17 | – | 600 | 18.0 | 12.1 | 13.00 | 11.00 |
CZB01811 |
|
|
|
|
|
|
|
|
|
|
AHP24 |
| 2,5,8,10 | 17 | – | 600 | 18.0 | 12.3 | 13.00 | 11.00 | |
| F*FP024 |
| 5,8,10 | 17 | – | 600 | 18.0 | 12.1 | 13.00 | 11.00 |
CZB02411 | AHP24 |
| 2,5,8,10 | 17 | – | 800 | 23.0 | 16.9 | 13.00 | 11.00 |
F*FP030 |
| 5,8,10,15 | 17 | – | 800 | 23.0 | 16.7 | 13.00 | 11.00 | |
|
| |||||||||
| AHP30 |
| 5,8,10 | 17 | – | 1000 | 30.0 | 21.9 | 13.00 | 11.00 |
CZB03011 | AHP36 |
| 5,8,10,15,18 | 17 | – | 1000 | 30.0 | 21.9 | 13.00 | 11.00 |
F*FP030 |
| 5,8,10,15 | 17 | – | 1000 | 29.6 | 21.6 | 13.00 | 11.00 | |
|
| |||||||||
| F*FP036 |
| 5,8,10,15,19 | 21 | – | 1000 | 30.0 | 22.3 | 13.00 | 11.00 |
| AHP36 |
| 5,8,10,15,18 | 17 | – | 1200 | 36.0 | 26.5 | 13.00 | 11.00 |
CZB03611 | AHP42 |
| 5,8,10,15,18 | 21 | – | 1200 | 36.0 | 26.5 | 13.00 | 11.00 |
F*FP036 |
| 5,8,10,15,19 | 21 | – | 1200 | 36.0 | 26.7 | 13.00 | 11.00 | |
|
| |||||||||
| F*FP042 |
| 5,8,10,15,18 | 21 | – | 1200 | 36.0 | 26.8 | 13.00 | 11.00 |
| AHP/SHP48 |
| 5,8,10,15,20 | 24 | – | 1400 | 41.5 | 30.5 | 13.00 | 11.00 |
CZB04211 | AHP/SHP60 |
| 5,8,10,15,20,25 | 24 | – | 1400 | 41.5 | 30.5 | 13.00 | 11.00 |
F*FP045 |
| 5,8,10,15 | 24 | – | 1400 | 41.0 | 30.2 | 13.00 | 11.00 | |
|
| |||||||||
| F*FP048 |
| 5,8,10,15 | 24 | – | 1400 | 41.0 | 30.2 | 13.00 | 11.00 |
CZB04811 | AHP/SHP48 |
| 5,8,10,15,20 | 24 | – | 1600 | 48.0 | 36.1 | 13.00 | 11.00 |
AHP/SHP60 |
| 5,8,10,15,20,25 | 24 | – | 1600 | 48.0 | 36.1 | 13.00 | 11.00 | |
|
| |||||||||
CZB06011 | AHP/SHP60 |
| 5,8,10,15,20,25 | 24 | – | 1800 | 55.5 | 39.7 | 13.00 | 11.00 |
|
|
| 1 PH 13 SEER | AC WITH AV / SV / F*FV VARIABLE SPEED |
|
|
| |||
CZB01811 | AV24 |
| 2,5,8,10 | 17 | – | 600 | 18.0 | 12.1 | 14.00 | 11.50 |
CZB02411 | AV24 |
| 2,5,8,10 | 17 | – | 800 | 23.0 | 16.7 | 14.00 | 11.50 |
CZB03011 | AV36 |
| 5,8,10,15,18 | 17 | – | 1000 | 30.0 | 21.9 | 14.00 | 11.50 |
CZB03611 | AV36 |
| 5,8,10,15,18 | 17 | – | 1200 | 36.0 | 26.5 | 14.00 | 11.50 |
CZB04211 | AV/SV48 |
| 5,8,10,15,20 | 24 | – | 1400 | 41.5 | 30.5 | 14.00 | 11.50 |
| AV/SV48 |
| 5,8,10,15,20 | 24 | – | 1600 | 48.0 | 35.8 | 14.00 | 11.50 |
CZB04811 |
|
|
|
|
|
|
|
|
|
|
AV/SV60 |
| 5,8,10,15,20,25 | 24 | – | 1600 | 48.0 | 35.8 | 14.00 | 11.50 | |
| F*FV060 |
| 5,8,10,15,20,25 | 24 | – | 1600 | 48.0 | 36.5 | 13.25 | 11.00 |
CZB06011 | AV/SV60 |
| 5,8,10,15,20,25 | 24 | – | 1800 | 57.0 | 40.8 | 14.00 | 11.50 |
F*FV060 |
| 5,8,10,15,20,25 | 24 | – | 1780 | 55.5 | 40.8 | 13.25 | 11.00 | |
|
|
Rated in accordance with DOE test procedures (Federal Register
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in
1MC & G*FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.