York 36, 60, 48 warranty YTG-A-0506

Page 15

255040-YTG-A-0506

TABLE 11: SUPPLY AIR BLOWER PERFORMANCE (6 TON BELT DRIVE) - SIDE DUCT APPLICATION

UNIT

AIR

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE-IWG3

 

 

 

 

 

 

FLOW

 

0.20

 

0.30

 

0.40

 

0.50

 

0.60

 

0.70

 

0.80

TONNAGE

 

 

 

 

 

 

 

 

CFM

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

 

 

 

 

 

 

 

 

 

 

3200

1150

 

2325

1182

 

2425

1212

 

2525

-

 

-

-

 

-

-

 

-

-

 

-

 

3000

1100

 

2010

1129

 

2090

1157

 

2150

1185

 

2225

1215

 

2290

1242

 

2360

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2800

1045

 

1700

1074

 

1780

1102

 

1850

1131

 

1940

1160

 

2025

1190

 

2075

1217

 

2130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

61, 2

2600

985

 

1425

1015

 

1475

1045

 

1540

1075

 

1630

1103

 

1715

1135

 

1760

1163

 

1825

2400

930

 

1240

958

 

1300

990

 

1350

1020

 

1400

1051

 

1430

1081

 

1490

1111

 

1600

 

 

 

 

 

 

 

 

 

2200

-

 

-

905

 

1070

933

 

1160

965

 

1210

997

 

1250

1028

 

1285

1060

 

1325

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

-

 

-

-

 

-

-

 

-

919

 

1025

950

 

1100

982

 

1130

1014

 

1160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

-

 

-

-

 

-

-

 

-

-

 

-

909

 

925

939

 

1005

968

 

1030

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

AIR

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE-IWG3

 

 

 

 

 

 

FLOW

 

0.90

 

1.00

 

1.10

 

1.20

 

1.30

 

1.40

 

1.50

TONNAGE

 

 

 

 

 

 

 

 

CFM

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

 

 

 

 

 

 

 

 

 

 

3200

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3000

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

 

2800

1245

 

2190

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

61, 2

2600

1193

 

1920

1222

 

1990

1250

 

2060

-

 

-

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2400

1142

 

1675

1173

 

1730

1205

 

1800

1234

 

1885

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2200

1090

 

1380

1124

 

1450

1155

 

1550

1186

 

1640

1217

 

1710

1249

 

1775

-

 

-

 

2000

1045

 

1175

1077

 

1200

1109

 

1275

1140

 

1360

1170

 

1460

1205

 

1545

1235

 

1600

 

1800

998

 

1050

1028

 

1060

1058

 

1060

1087

 

1075

1118

 

1150

1148

 

1250

1176

 

1360

1.230/460/575 Volts

2.For 208 Volts multiply values by 0.95.

3.Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows.

Unitary Products Group

15

Image 15
Contents Description WarrantyTable of Contents Product Nomenclature Factory Installed HeatFeatures FIELD-INSTALLED Accessories FACTORY-INSTALLED OptionsYTG-A-0506 Sound Power RATING1 Capacity Ratings ARI 210/2401GAS Heat RATINGS1 DCE, CG036 Cooling Capacities 3 TON Nominal RatingDCE, CG048 Cooling Capacities 4 TON DCE, CG060 Cooling Capacities 5 TON DCE, CG072 Cooling Capacities 6 TON 31,2 YTG-A-0506 YTG-A-0506 YTG-A-0506 MED Belt Drive Blower Motor and Drive DataElectric Heater CFM Limitations Static ResistancesElectrical Data DCE, CG036-072 Direct Drive DCE, CG Electrical Data DCE, CG036-072 Belt Drive 2CE04511525 15.9 38.2 54.3 Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 6 TON COOLING/GAS Heat Front View Detail a Minimum Clearances Tion Utilities EntryTypical Applications Unit Total Center of GravityRoof Curb Dimensions Operating Weights LBSYTG-A-0506 Cooling Unit with GAS Heat Control Circuit 575 Volt Diagram YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 Unit Cabinet Guide SpecificationsIndoor Evaporator FAN Assembly Outdoor Condenser FAN AssemblyElectric Heating Section Unit Operating CharacteristicsUnit Controls GAS Heating SectionManual Outdoor AIR Damper Other PRE-ENGINEERED Accessories AvailableStandard Limited Warranties Electric HeatersYTG-A-0506 YTG-A-0506 YTG-A-0506
Related manuals
Manual 24 pages 35.6 Kb

48, 60, 36 specifications

York 36, 48, and 60 are three distinct models from the York line of heating, ventilation, and air conditioning (HVAC) systems, specifically designed to meet various commercial and residential needs. Each model fits specific sizing and efficiency requirements while employing advanced technologies to enhance performance.

The York 36 model is ideal for smaller spaces or residential applications. This unit boasts a compact design that integrates seamlessly into tight locations while offering substantial energy efficiency. With a cooling capacity of approximately 36,000 BTU, it’s suitable for apartments or small commercial areas. The use of scroll compressors in this model contributes to reliable operation and quieter performance. Additionally, it utilizes environmentally friendly refrigerants that comply with modern environmental regulations, making it a sustainable choice.

The York 48 model steps up its capabilities for larger residential and commercial buildings. It provides ample cooling capacity at around 48,000 BTU, accommodating medium-sized spaces effectively. One of the standout features is its two-stage cooling technology, which allows for consistent temperature control without excessive energy consumption. This model is equipped with variable speed blowers that optimize airflow, ensuring a comfortable indoor environment even during peak summer months. The York 48 is also engineered with advanced diagnostics, allowing technicians to identify and resolve issues quickly, further enhancing reliability.

Finally, the York 60 model caters to extensive commercial applications with its impressive cooling capacity of approximately 60,000 BTU. This unit excels in large offices, retail spaces, and industrial settings. It employs advanced inverter technology, which adjusts compressor speed based on demand, leading to remarkable energy efficiency and significant cost savings in long-term operation. The York 60 also features robust insulation and weather-tight cabinet design to minimize energy loss. Additionally, its user-friendly interface allows for easy control and monitoring, ensuring optimal performance.

All three York models come equipped with state-of-the-art filters and air purifiers, improving indoor air quality by effectively reducing allergens and pollutants. With a focus on durability, energy efficiency, and advanced technology, York 36, 48, and 60 units represent versatile solutions for their respective applications, demonstrating York's commitment to innovation and sustainability in HVAC systems. Whether for a small apartment or a large commercial space, these units offer reliable comfort and performance tailored to specific needs.