York 36, 60, 48 warranty 31,2

Page 12

255040-YTG-A-0506

TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION

UNIT

AIR

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE-IWG3

 

 

 

 

 

 

FLOW

 

0.20

 

0.30

 

0.40

 

0.50

 

0.60

 

0.70

 

0.80

TONNAGE

 

 

 

 

 

 

 

 

CFM

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

 

 

 

 

 

 

 

 

 

 

1700

835

 

705

880

 

745

923

 

795

969

 

860

1013

 

970

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

811

 

655

854

 

695

898

 

740

942

 

790

986

 

840

1029

 

900

-

 

-

 

1500

782

 

610

827

 

650

871

 

685

917

 

730

960

 

775

1003

 

825

1046

 

905

 

1400

-

 

-

798

 

595

844

 

640

889

 

680

932

 

720

975

 

765

1018

 

790

31,2

1300

-

 

-

-

 

-

816

 

590

862

 

635

907

 

675

951

 

715

995

 

750

 

1200

-

 

-

-

 

-

-

 

-

834

 

585

881

 

630

927

 

665

970

 

705

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

-

 

-

-

 

-

-

 

-

809

 

550

855

 

590

900

 

625

942

 

665

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

-

 

-

-

 

-

-

 

-

782

 

510

829

 

545

872

 

858

919

 

625

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

900

-

 

-

-

 

-

-

 

-

-

 

-

797

 

500

843

 

540

890

 

580

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

AIR

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE-IWG3

 

 

 

 

 

 

FLOW

 

0.90

 

1.00

 

1.10

 

1.20

 

1.30

 

1.40

 

1.50

TONNAGE

 

 

 

 

 

 

 

 

CFM

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

RPM

 

WATTS

 

 

 

 

 

 

 

 

 

 

1700

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

1055

 

875

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

31, 2

1300

1036

 

780

1066

 

850

-

 

-

-

 

-

-

 

-

-

 

-

-

 

-

 

1200

1011

 

735

1047

 

765

1075

 

800

-

 

-

-

 

-

-

 

-

-

 

-

 

1100

987

 

690

1028

 

720

1060

 

750

1084

 

775

-

 

-

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

963

 

655

1005

 

680

1040

 

695

1068

 

715

1089

 

735

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

900

936

 

615

980

 

645

1020

 

660

1050

 

670

1053

 

680

1090

 

690

-

 

-

1.230/460/575 Volts

2.For 208 Volts multiply values by 0.95.

3.Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows.

12

Unitary Products Group

Image 12
Contents Warranty DescriptionTable of Contents Factory Installed Heat Product NomenclatureFeatures FACTORY-INSTALLED Options FIELD-INSTALLED AccessoriesYTG-A-0506 Sound Power RATING1 Capacity Ratings ARI 210/2401GAS Heat RATINGS1 Nominal Rating DCE, CG036 Cooling Capacities 3 TONDCE, CG048 Cooling Capacities 4 TON DCE, CG060 Cooling Capacities 5 TON DCE, CG072 Cooling Capacities 6 TON 31,2 YTG-A-0506 YTG-A-0506 YTG-A-0506 Belt Drive Blower Motor and Drive Data MEDStatic Resistances Electric Heater CFM LimitationsElectrical Data DCE, CG036-072 Direct Drive DCE, CG Electrical Data DCE, CG036-072 Belt Drive 2CE04511525 15.9 38.2 54.3 Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 6 TON COOLING/GAS Heat Front View Detail a Tion Utilities Entry Minimum ClearancesTypical Applications Center of Gravity Unit TotalOperating Weights LBS Roof Curb DimensionsYTG-A-0506 Cooling Unit with GAS Heat Control Circuit 575 Volt Diagram YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 YTG-A-0506 Guide Specifications Indoor Evaporator FAN AssemblyOutdoor Condenser FAN Assembly Unit CabinetUnit Operating Characteristics Unit ControlsGAS Heating Section Electric Heating SectionOther PRE-ENGINEERED Accessories Available Standard Limited WarrantiesElectric Heaters Manual Outdoor AIR DamperYTG-A-0506 YTG-A-0506 YTG-A-0506
Related manuals
Manual 24 pages 35.6 Kb

48, 60, 36 specifications

York 36, 48, and 60 are three distinct models from the York line of heating, ventilation, and air conditioning (HVAC) systems, specifically designed to meet various commercial and residential needs. Each model fits specific sizing and efficiency requirements while employing advanced technologies to enhance performance.

The York 36 model is ideal for smaller spaces or residential applications. This unit boasts a compact design that integrates seamlessly into tight locations while offering substantial energy efficiency. With a cooling capacity of approximately 36,000 BTU, it’s suitable for apartments or small commercial areas. The use of scroll compressors in this model contributes to reliable operation and quieter performance. Additionally, it utilizes environmentally friendly refrigerants that comply with modern environmental regulations, making it a sustainable choice.

The York 48 model steps up its capabilities for larger residential and commercial buildings. It provides ample cooling capacity at around 48,000 BTU, accommodating medium-sized spaces effectively. One of the standout features is its two-stage cooling technology, which allows for consistent temperature control without excessive energy consumption. This model is equipped with variable speed blowers that optimize airflow, ensuring a comfortable indoor environment even during peak summer months. The York 48 is also engineered with advanced diagnostics, allowing technicians to identify and resolve issues quickly, further enhancing reliability.

Finally, the York 60 model caters to extensive commercial applications with its impressive cooling capacity of approximately 60,000 BTU. This unit excels in large offices, retail spaces, and industrial settings. It employs advanced inverter technology, which adjusts compressor speed based on demand, leading to remarkable energy efficiency and significant cost savings in long-term operation. The York 60 also features robust insulation and weather-tight cabinet design to minimize energy loss. Additionally, its user-friendly interface allows for easy control and monitoring, ensuring optimal performance.

All three York models come equipped with state-of-the-art filters and air purifiers, improving indoor air quality by effectively reducing allergens and pollutants. With a focus on durability, energy efficiency, and advanced technology, York 36, 48, and 60 units represent versatile solutions for their respective applications, demonstrating York's commitment to innovation and sustainability in HVAC systems. Whether for a small apartment or a large commercial space, these units offer reliable comfort and performance tailored to specific needs.