York DJ 150 manual Table of Contents

Page 2

246695-YTG-C-0708

TABLE OF CONTENTS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . 5 FIELD INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . 6 NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . 26

 

LIST OF FIGURES

Fig. #

Pg. #

1 PREDATOR® MAGNUM COMPONENT LOCATION . . 3 2 UNIT 4 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . 16 3 UNIT CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . 16 4 UNIT WITH 6 POINT LOAD . . . . . . . . . . . . . . . . . . . . 16 5 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 17

6 PREDATOR® MAGNUM ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

7 SUNLINE™ TO PREDATOR® MAGNUM TRANSITION ROOF CURBS . . . . . . . . . . . . . . . . . . . 18

8 BOTTOM DUCT OPENINGS (FROM ABOVE) . . . . . 19 9 SIDEFLOW DUCT DIMENSIONS . . . . . . . . . . . . . . . 19 10 DOWNFLOW ECONOMIZER HOOD DETAIL . . . . . . 20

11 FACTORY INSTALLED DOWNFLOW ECONOMIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

12 FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . 21

13 FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . 21

14 SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

15 SLAB ECONOMIZER END RETURN W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

16 COOLING UNIT WITH GAS HEAT WIRING 230 V. DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

17 COOLING UNIT W/WO ELECTRIC HEAT WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

18 COOLING UNIT WITH GAS HEAT WIRING 460,

575 & 50 HZ DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . 25

 

LIST OF TABLES

 

Tbl. #

Pg. #

1

ACCESSORIES

. . . 8

2

PHYSICAL DATA

. . 10

3

DJ 150 (12-1/2 TON) CAPACITY RATINGS

. . 10

4

UNIT VOLTAGE LIMITATIONS

. . 10

5

DJ 150 (12 1/2 TON) COOLING CAPACITY

. . 11

6

ELECTRICAL DATA DJ150 (12-1/2 TON) W/O PWRD

 

CONVENIENCE OUTLET

. . 12

7

ELECTRICAL DATA DJ150 (12-1/2 TON) WITH PWRD

 

CONVENIENCE OUTLET

. . 12

8

ELECTRIC HEAT MULTIPLIERS

. . 12

9

BLOWER PERFORMANCE 12-1/2 TON SIDE

 

 

DUCT

. . 13

10

BLOWER PERFORMANCE 12-1/2 TON

 

 

DOWNSHOT

. . 14

11

ADDITIONAL STATIC RESISTANCE

. . 15

12

ELECTRIC HEAT MINIMUM SUPPLY AIR CFM . .

. . 15

13

INDOOR BLOWER SPECIFICATIONS

. . 15

14

POWER EXHAUST SPECIFICATIONS

. . 15

15

4 POINT LOAD WEIGHT

. . 16

16

6 POINT LOAD WEIGHT

. . 16

17

UNIT WEIGHTS

. . 16

18

UNIT CLEARANCES

. . 17

19

ECONOMIZER USAGE

. . 20

2

Johnson Controls Unitary Products

Image 2
Contents Technical Guide Table of Contents Features Johnson Controls Unitary Products Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Accessories Part Number Description WeightTon Model Number Nomenclature Unit Voltage Limitations Physical DataDJ 150 12-1/2 TON Capacity Ratings DJ 150 12 1/2 TON Cooling Capacity MBHElectrical Data DJ150 12-1/2 TON W/O Pwrd Convenience Outlet Electric Heat MultipliersBlower Performance 12-1/2 TON Side Duct 4900Blower Performance 12-1/2 TON Downshot Additional Static Resistance Indoor Blower SpecificationsPower Exhaust Specifications Electric Heat Minimum Supply AIR CFMModel Locations lbs Unit WeightsModel Location lbs Unit Dimensions Unit Clearances Detail CPredator Magnum Roof Curb Dimensions Bottom Duct Openings from Above Downflow Economizer Hood Detail Economizer Usage Application Description ModelField Installed Downflow Economizer W/POWER Exhaust Slab Economizer Downflow W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 V. Diagram Cooling Unit W/WO Electric Heat Wiring Diagram Cooling Unit with GAS Heat Wiring 460, 575 & 50 HZ Diagram General Indoor Evaporator FAN AssemblyOutdoor Condenser FAN Assembly DescriptionElectric Heating Section if Equipped Unit Operating CharacteristicsGAS Heating Section if Equipped Electrical RequirementsJohnson Controls Unitary Products York Drive Norman, OK Additional Factory Installed OptionsOther PRE-ENGINEERED Accessories AVAIL- Able
Related manuals
Manual 28 pages 11.03 Kb