Replacing, moving, or adding hard drives
In this section |
|
Identifying the status of a hard drive | 22 |
Recognizing hard drive failure | 23 |
Replacing hard drives | 24 |
Moving drives and arrays | 28 |
Adding drives | 28 |
Identifying the status of a hard drive
When a drive is configured as a part of an array and connected to a
Item | Description |
1Fault/ID LED (amber/blue)
2Online LED (green)
Online/Activity | Fault/UID LED | Interpretation |
|
LED (green) | (amber/blue) |
|
|
|
|
|
|
On, off, or flashing | Alternating amber | The drive has failed, or a predictive failure alert has been |
|
| and blue | received for this drive; it also has been selected by a |
|
|
| management application. |
|
On, off, or flashing | Steadily blue | The drive is operating normally, and it has been selected by a |
|
|
| management application. |
|
|
|
|
|
On | Amber, flashing | A predictive failure alert has been received for this drive. |
|
| regularly (1 Hz) | Replace the drive as soon as possible. |
|
|
|
| |
|
|
|
|
|
| Replacing, moving, or adding hard drives 22 |