HP E200 manual Replacing, moving, or adding hard drives, Identifying the status of a hard drive

Page 22

Replacing, moving, or adding hard drives

In this section

 

Identifying the status of a hard drive

22

Recognizing hard drive failure

23

Replacing hard drives

24

Moving drives and arrays

28

Adding drives

28

Identifying the status of a hard drive

When a drive is configured as a part of an array and connected to a powered-up controller, the condition of the drive can be determined from the illumination pattern of the hard drive status lights (LEDs).

Item

Description

1Fault/ID LED (amber/blue)

2Online LED (green)

Online/Activity

Fault/UID LED

Interpretation

 

LED (green)

(amber/blue)

 

 

 

 

 

 

On, off, or flashing

Alternating amber

The drive has failed, or a predictive failure alert has been

 

 

and blue

received for this drive; it also has been selected by a

 

 

 

management application.

 

On, off, or flashing

Steadily blue

The drive is operating normally, and it has been selected by a

 

 

 

management application.

 

 

 

 

 

On

Amber, flashing

A predictive failure alert has been received for this drive.

 

 

regularly (1 Hz)

Replace the drive as soon as possible.

 

 

 

 

 

 

 

 

 

 

Replacing, moving, or adding hard drives 22

Image 22
Contents HP Smart Array E200 Controller User Guide Audience assumptions Contents Diagnosing array problems Controller specifications Hardware featuresBoard components Cache on Installing the controller in an unconfigured server Overview of the installation procedureInstalling the controller in a previously configured server Overview of the installation procedure Before beginning the installation Preparing the server Installing the controller hardwareInstalling the controller board Connecting storage devices Updating the firmware Methods for updating the firmwareIntroduction Configuring an arrayComparing the utilities Using Orca Select Create Logical DriveUsing ACU Using CpqonlinExpanding an array Migrating RAID level and stripe size online Setting a controller as the boot controller Setting the boot controller and controller orderSetting the controller order Installing device drivers Installing device drivers and Management AgentsInstalling Management Agents Replacing a battery Upgrading or replacing controller optionsUpgrading the cache Upgrading or replacing controller options Replacing, moving, or adding hard drives Identifying the status of a hard driveRecognizing hard drive failure Terminate the current operation and cause data lossReplacing hard drives Effects of a hard drive failureHard drive replacement guidelines Time required for a rebuild Upgrading hard drive capacity Moving drives and arrays Adding drivesReplacing, moving, or adding hard drives Diagnosing array problems Controller board runtime LEDsBattery pack LEDs LEDDiagnostic tools ADUPreventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge European Union regulatory notice Regulatory compliance noticesBsmi notice Korean class B notice Battery replacement notice Taiwan battery recycling noticeAcronyms and abbreviations Index Status lights, battery pack