HP E200 manual Replacing, moving, or adding hard drives

Page 29

The expansion process is illustrated in the following figure, in which the original array (containing data) is shown with a dashed border and the newly added drives (containing no data) are shown unshaded. The array controller adds the new drives to the array and redistributes the original logical drives over the enlarged array one logical drive at a time. This process liberates some storage capacity on each of the physical drives in the array. During this procedure, the logical drives each keep the same fault-tolerance method in the enlarged array that they had in the smaller array.

When the expansion process has finished, you can use the liberated storage capacity on the enlarged array to create new logical drives. Alternatively, you can enlarge one of the original logical drives. This latter process is called logical drive capacity extension and is also carried out using ACU.

Replacing, moving, or adding hard drives 29

Image 29
Contents HP Smart Array E200 Controller User Guide Audience assumptions Contents Diagnosing array problems Board components Hardware featuresController specifications Cache on Installing the controller in a previously configured server Overview of the installation procedureInstalling the controller in an unconfigured server Overview of the installation procedure Installing the controller board Installing the controller hardwareBefore beginning the installation Preparing the server Connecting storage devices Methods for updating the firmware Updating the firmwareComparing the utilities Configuring an arrayIntroduction Select Create Logical Drive Using OrcaUsing Cpqonlin Using ACUExpanding an array Migrating RAID level and stripe size online Setting the controller order Setting the boot controller and controller orderSetting a controller as the boot controller Installing Management Agents Installing device drivers and Management AgentsInstalling device drivers Upgrading or replacing controller options Replacing a batteryUpgrading the cache Upgrading or replacing controller options Identifying the status of a hard drive Replacing, moving, or adding hard drivesTerminate the current operation and cause data loss Recognizing hard drive failureEffects of a hard drive failure Replacing hard drivesHard drive replacement guidelines Time required for a rebuild Upgrading hard drive capacity Adding drives Moving drives and arraysReplacing, moving, or adding hard drives Controller board runtime LEDs Diagnosing array problemsLED Battery pack LEDsADU Diagnostic toolsGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Bsmi notice Regulatory compliance noticesEuropean Union regulatory notice Taiwan battery recycling notice Korean class B notice Battery replacement noticeAcronyms and abbreviations Index Status lights, battery pack