York Comprehensive Technical Guide for Air Conditioners

Page 1

®

Technical Guide

SINGLE PACKAGE

GAS / ELECTRIC UNITS AND

SINGLE PACKAGE AIR CONDITIONERS

D2CE / D2CG 300 CONSTANT VOLUME 25 NOMINAL TONS

8.5EER

SUNLINE 2000 ™

036-21359-001-B-0302

DESCRIPTION

Sunline™ 2000 series convertible package rooftop mod- els have two independent refrigerant circuits for efficient part load operation. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof.

Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory- mounted options and field-installed accessories to make them suitable for almost every application.

All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging.

Every unit is completely piped, wired, charged and tested at the factory to simplify field installation and to provide years of dependable operation. Powder paint cabinets pro- vide an exceptionally durable finish with the 750 hour salt spray process per ASTM-B117 test standard.

All models (including those with an economizer) are suit- able for either bottom or horizontal duct connections. Mod- els with power exhaust are suitable for bottom duct connections only. For bottom duct, you remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, you replace the supply and return air panels on the rear of the unit with a side duct flange accessory.

All models are available with five different outdoor air damper options:

Single enthalpy economizer

Differential (dual) enthalpy economizer

Single enthalpy economizer with power exhaust

Differential (dual) enthalpy economizer with power exhaust

Motorized outdoor air damper

A fixed outdoor air intake assembly is shipped in the return air compartment of all units ordered without an economizer or motorized outdoor air damper option. The assembly includes a rain hood with a damper that can be set for 10, 15 or 25% outdoor air. With bottom duct connections, the intake damper assembly should be mounted over the opening in the return air panel. With horizontal ductwork, it should be mounted on the return air duct.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

Image 1
Contents Description Technical GuidePower Exhaust FACTORY-INSTALLED OptionsEconomizers Motorized Outdoor AIR Intake DamperFIELD-INSTALLED Accessories Capacity Ratings ARI Coil Guard KITCooling with GAS Heat GAS Heat RatingsCFM MBHFactory Setting Accessory DriveBlower Pulley Speed Turns ESP Output InputModel Size MBH DCE/DCG/DCV ModelsEvaporator Blower Coil Condenser FAN Condenser Coil CompressorOUT Adjustablemotorpulley Fixed Blower PUL LEYSize Frame Desig SideA N S F O R M E M P E R L TN E V O L T a G E R M I N a LUtilities Entry Data ViewX E D T DA OI RO R I N Thaokoe D Npdo WE EX RH RA Auhisonto D SO N T 300 130 418 438 533 658 603 510Base Rail 036-21359-001-B-0302 Mechanical Specifications GAS Heating Section DCG Models Unit Operating CharacteristicsElectric Heating DCE Models Electrical Requirements Other PRE-ENGINEERED Accessories AVAIL- AbleStandard Limited Warranties Other Factory Installed Options 036-21359-001-B-0302 036-21359-001-B-0302 036-21359-001-B-0302 036-21359-001-B-0302 036-21359-001-B-0302 036-21359-001-B-0302
Related manuals
Manual 24 pages 32.97 Kb

D2CG, D2CE specifications

The York D2CE and D2CG series represent cutting-edge advancements in energy-efficient chiller technology, specifically designed to optimize performance in a variety of commercial and industrial applications. These chillers are known for their ability to deliver reliable cooling while minimizing energy consumption, making them a preferred choice for businesses aiming to reduce their carbon footprint and operational costs.

One of the standout features of the York D2CE and D2CG chillers is their utilization of advanced scroll compressor technology. This technology not only enhances the reliability of the systems but also significantly improves energy efficiency, allowing for lower operational costs. The chillers are built to provide high efficiency across a diverse range of operating conditions, ensuring consistent performance during peak loads.

The D2CE series, designed primarily for air-cooled applications, benefits from a compact and modular design, allowing for flexible installation in tight spaces. Additionally, its quiet operation makes it suitable for use in noise-sensitive environments, such as healthcare facilities and educational institutions. The model is equipped with microprocessor controls that facilitate precise temperature regulation and system diagnostics, ensuring optimal operation.

Conversely, the D2CG series focuses on water-cooled applications, featuring robust construction that accommodates higher cooling capacities. This model also includes advanced heat exchanger technology, which maximizes heat transfer efficiency. The D2CG’s intelligent controls not only help in energy management but also provide remote monitoring capabilities, allowing facility managers to analyze performance and troubleshoot issues from anywhere.

Both models utilize environmentally friendly refrigerants, aligning with global regulations and promoting sustainability. Enhanced filtration options are available, enabling the units to maintain high indoor air quality by minimizing dust and other pollutants.

In addition to their energy-saving attributes, the York D2CE and D2CG chillers are designed for ease of maintenance, with accessible components and modular parts that simplify service procedures. This, coupled with their durable construction, leads to greater longevity and reliability in operation.

In summary, the York D2CE and D2CG chillers are leading examples of modern HVAC engineering, combining efficiency, flexibility, and sustainability. Their innovative technologies and thoughtful design make them an excellent addition to any facility looking to enhance its cooling systems while adhering to environmental standards.