Clearing the CMOS

Clearing the CMOS

If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to be used to reset the configuration RAM.

1.Power down the system and disconnect the AC power.

2.Open the server.

3.Move the jumper (J1J1) from the normal operation position, CMOS Clear by BMC, at pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3 as indicated in the following diagram.

CMOS PASSWORD

CLR CLR

2

3

J1J1

Figure 6. CMOS Clear Jumper Default

CLEAR 2

CMOS 3

J1J2

Manual background Default

CLEAR PASSWORD

AF000187

Figure 6. CMOS Clear Jumper

4.Reconnect the AC power, power up the system.

5.When the system begins beeping, power it down and disconnect the AC power.

6.Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2.

7.Close the server chassis.

8.Reconnect the AC power and power up the system.