INSTALLATION INSTRUCTION

TABLE OF CONTENTS

GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . 2 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CHECK ELECTRICAL POWER SUPPLY . . . . . . . . . 2 SELECTING EQUIPMENT LOCATION . . . . . . . . . . 2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 4

OUTDOOR UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INDOOR UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 REFRIGERANT LINE (SWEAT FIT) . . . . . . . . . . . . . 4 INSULATION OF VAPOR LINE . . . . . . . . . . . . . . . . 4

RE-ASSEMBLING, BRAZING AND CLEANING OF JOINT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . 5 REFRIGERANT LINE SUPPORT . . . . . . . . . . . . . . . 5 CHARGING AND LEAK TESTING . . . . . . . . . . . . . . 5 TOTAL LINE LENGTH . . . . . . . . . . . . . . . . . . . . . . . 5

ORIFICE SELECTION (ON SWEAT FIT COILS) . . . 5 REFRIGERANT VALVE OPERATION . . . . . . . . . . . 6 OIL TRAPPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . 8

MEASUREMENT METHOD . . . . . . . . . . . . . . . . . . . 8 SUPERHEAT CHARGING METHOD . . . . . . . . . . . . 8 CHECKOUT PROCEDURE . . . . . . . . . . . . . . . . . . 10 SYSTEM OPERATION CHECKOUT . . . . . . . . . . . 10

CAUTION:READ ALL SAFETY GUIDES BEFORE YOU START TO INSTALL YOUR UNIT.

SAVE THIS MANUAL

OUTDOOR SPLIT-SYSTEM

AIR CONDITIONER

MODELS: 10, 12, 13 AND 14 SEER

1 PHASE - 1.5 TO 5 TONS

035-13606-003 Rev. A (202)

Image 1
Contents Installation Instruction General Information Check Electrical Power SupplyInspection ReferenceTypical Residential Outdoor Unit Location Outdoor Unit InstallationIndoor Units Refrigerant Line Sweat FITCharging and Leak Testing RE-ASSEMBLING, Brazing and Cleaning of Joint ConnectionsRefrigerant Line Support Total Line LengthOIL Trapping Refrigerant Valve Operation Electrical WiringTypical Condensing Unit Control Box Start Components Shown Measurement Method System ChargeSuperheat Charging Method Superheat Value System Operation Checkout Checkout ProcedureService Records Products York Group Drive 73069

13 AND 14 SEER, 12, 10 specifications

When considering air conditioning systems for residential or commercial spaces, the SEER (Seasonal Energy Efficiency Ratio) rating plays a crucial role in determining energy efficiency and performance. Among the popular choices in the market are the York 12, 13, and 14 SEER air conditioning units, each designed to provide optimal cooling while ensuring cost efficiency and environmental sustainability.

York’s 12 SEER air conditioners are an excellent entry-level option for homeowners looking to upgrade their cooling systems without breaking the bank. These units offer reliable cooling performance while maintaining moderate energy consumption. One of their main features is the use of energy-efficient compressors and fan motors that enhance overall performance. The units are also designed with durable materials for extended life expectancy. Additionally, they come with easy-to-use thermostats that allow for precise temperature control, making them an ideal choice for those seeking dependable cooling at a reasonable price.

Stepping up to the York 13 SEER units, these models provide a higher level of energy efficiency and cooling capacity. They incorporate advanced technologies, such as improved heat exchangers and multi-speed blower motors that optimize airflow while minimizing energy consumption. The 13 SEER units are designed for quiet operation, making them suitable for residential areas where noise can be a significant concern. Enhanced filtration systems are another standout feature, capturing more airborne particles and allergens, contributing to improved indoor air quality.

For those seeking the best in energy efficiency and performance, the York 14 SEER air conditioners offer standout characteristics. These high-efficiency units leverage technologies such as scroll compressors and variable-speed blowers, allowing for precise cooling and energy savings throughout the cooling season. The 14 SEER models also feature smart controls, often compatible with home automation systems, which enable users to monitor and adjust settings remotely for maximum convenience. Noise reduction is a significant factor as well, with specially designed sound insulation that promotes quiet operation.

In summary, York’s 12, 13, and 14 SEER air conditioning units showcase a range of performance and efficiency options suitable for various needs. The 12 SEER models are perfect for budget-conscious consumers, while the 13 SEER units offer enhanced efficiency and comfort. The 14 SEER air conditioners represent the pinnacle of cooling technology in York’s lineup, perfect for those prioritizing energy savings and advanced features. Each model reflects York's commitment to quality, reliability, and environmental responsibility, making them a smart choice for any air conditioning needs.