York 10, 12, 13 AND 14 SEER manual Refrigerant Valve Operation Electrical Wiring, OIL Trapping

Page 6

035-13606-003 Rev. A (202)

REFRIGERANT VALVE OPERATION

ELECTRICAL WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All outdoor units are shipped with the service valves in the closed position. After installation of the refrigerant and proper evacuation, make sure that all valves are in the open position and that the caps are securely tightened before turning ON the electrical power to the outdoor unit.

All models in this series have brass service valves. These valves are not back seating. Opening or closing valve does not close service port. Service ports have Schrader valves for gauge connections. Use back-up wrench on valve body when removing cap to open or close the valve. To open, insert hex wrench into stem and back out counter clockwise until stem

just touches retaining ring.

If the valve stem is backed out beyond the retain- ing ring, system pressure could force the stem out of the valve body and possibly cause per- sonal injury. In the event that the retaining ring is missing do not attempt to open the valve.

Some units may have factory installed 1-1/8" ball valves. To open the valve, remove the brass valve stem cap, located on the side of the valve, with an adjustable wrench. Next, turn the valve stem 1/4 turn CCW (away from unit).

All caps must be replaced to prevent leaks.

Replace valve cap finger tight, then tighten an additional 1/6 of a turn with a wrench, using a back-up wrench on the valve body.

OIL TRAPPING

When the outdoor unit is above the indoor coil oil trapping is necessary. Please refer to APPLICATION DATA, 690.01- AD1V (1296) and worksheet 690.01-AD1.1V (791) “General Piping Recommendations and Refrigerant Line length".

Check the system for correct charge after all components of the system have been installed, connected and wired cor- rectly.

Connect service gauges to low pressure port and discharge service ports.

Allow unit to operate until system pressures and tempera- tures have stabilized, making sure that the pressure and tem- perature align with unit service data. If not, check system charge and adjust if necessary.

To prevent electrical shock, open remote discon- nect so electrical supply to outdoor unit is shut off. Contactor does not open both sides of the 208/230 volt electrical circuit.

POWER SUPPLY

All wiring must comply with N.E.C. and local codes. See rat- ing plate and product data sheet for volts, frequency, phase, maximum fuse size and minimum branch circuit ampacity.

Refer to the wiring diagram inside the unit control box cover before connecting to power supply.

1.The 208/230 volt single phase line voltage service wiring for the outdoor unit must include a disconnect switch located within sight of the outdoor unit.

2.Use the correct size fuse or circuit breaker as listed on the unit rating plate and data sheet. If using nonmetallic- sheathed cable (NM or NM-B) ampacities shall be that of 60° C conductors per N.E.C 336-26.

3.Wiring connections. - Two are provided in the control box:

a.One for low voltage wiring.

b.One entrance for high voltage L1 and L2.

The adjustable High Voltage Conduit Plate is factory installed for 1/2" conduit connections. For 3/4" conduit, remove the screw holding the plate in place and adjust the location of the holes. For 1" conduit, remove the conduit plate and discard. Re-install screw to maintain the integrity of the unit structure, regardless of the conduit being used. See Figures 9, 10 & 11.

4.Power connection to the unit is facilitated by screw termi- nals, L1 and L2 on the outdoor unit contactor. See Fig- ures 9, 10 & 11.

5.Ground the outdoor unit using the ground lug provided. Unless the outdoor unit is grounded through proper wir- ing to the service entrance ground, a suitable separate ground should be provided at the outdoor unit.

6.Use copper conductors only.

Casing or cabinet must be permanently grounded in accordance with National Electric Code or other applicable local codes.

6

Unitary Products Group

Image 6
Contents Installation Instruction Inspection Check Electrical Power SupplyGeneral Information ReferenceTypical Residential Outdoor Unit Location Indoor Units InstallationOutdoor Unit Refrigerant Line Sweat FITRefrigerant Line Support RE-ASSEMBLING, Brazing and Cleaning of Joint ConnectionsCharging and Leak Testing Total Line LengthRefrigerant Valve Operation Electrical Wiring OIL TrappingTypical Condensing Unit Control Box Start Components Shown System Charge Measurement MethodSuperheat Charging Method Superheat Value Checkout Procedure System Operation CheckoutService Records Products York Group Drive 73069

13 AND 14 SEER, 12, 10 specifications

When considering air conditioning systems for residential or commercial spaces, the SEER (Seasonal Energy Efficiency Ratio) rating plays a crucial role in determining energy efficiency and performance. Among the popular choices in the market are the York 12, 13, and 14 SEER air conditioning units, each designed to provide optimal cooling while ensuring cost efficiency and environmental sustainability.

York’s 12 SEER air conditioners are an excellent entry-level option for homeowners looking to upgrade their cooling systems without breaking the bank. These units offer reliable cooling performance while maintaining moderate energy consumption. One of their main features is the use of energy-efficient compressors and fan motors that enhance overall performance. The units are also designed with durable materials for extended life expectancy. Additionally, they come with easy-to-use thermostats that allow for precise temperature control, making them an ideal choice for those seeking dependable cooling at a reasonable price.

Stepping up to the York 13 SEER units, these models provide a higher level of energy efficiency and cooling capacity. They incorporate advanced technologies, such as improved heat exchangers and multi-speed blower motors that optimize airflow while minimizing energy consumption. The 13 SEER units are designed for quiet operation, making them suitable for residential areas where noise can be a significant concern. Enhanced filtration systems are another standout feature, capturing more airborne particles and allergens, contributing to improved indoor air quality.

For those seeking the best in energy efficiency and performance, the York 14 SEER air conditioners offer standout characteristics. These high-efficiency units leverage technologies such as scroll compressors and variable-speed blowers, allowing for precise cooling and energy savings throughout the cooling season. The 14 SEER models also feature smart controls, often compatible with home automation systems, which enable users to monitor and adjust settings remotely for maximum convenience. Noise reduction is a significant factor as well, with specially designed sound insulation that promotes quiet operation.

In summary, York’s 12, 13, and 14 SEER air conditioning units showcase a range of performance and efficiency options suitable for various needs. The 12 SEER models are perfect for budget-conscious consumers, while the 13 SEER units offer enhanced efficiency and comfort. The 14 SEER air conditioners represent the pinnacle of cooling technology in York’s lineup, perfect for those prioritizing energy savings and advanced features. Each model reflects York's commitment to quality, reliability, and environmental responsibility, making them a smart choice for any air conditioning needs.