5.When POST is completed, disconnect the tip window as follows:

5.When POST is completed, disconnect the tip window as follows:

a.Open a shell window.

b.Type ps -ato view the active tip line and process ID (PID) number.

c.Type the following to kill the tip hardwire process.

%kill -9<Process ID (PID) Number>

Verifying the Baud Rate

To verify the baud rate between the Sun Enterprise 220R server and a terminal or another Sun system monitor:

1.Open a shell window.

2.Type eeprom.

3.Verify the following serial port default settings as follows:

ttyb-mode = 9600,8,n,1 ttya-mode = 9600,8,n,1

Note Ensure that the settings are consistent with TTY-type terminal or system monitor settings.

What to Do

Ensure that the front panel keyswitch is in the Standby position.

For descriptions of the keyswitch settings, see “About the Status and Control Panel” on page 7.

You can initialize POST one of two ways.

By setting the diag-switch?to true and the diag-levelto max or min, followed by power cycling the system unit.

By simultaneously pressing the keyboard Stop and D keys while power is applied to the system unit.

Chapter 7 Diagnostics and Troubleshooting 123