York 292443-XTG-D-0508 manual DNA048 Cooling Capacities 4 TON, AIR on

Page 11

292443-XTG-D-0508

TABLE 6: DNA048 COOLING CAPACITIES - 4 TON

TEMPERATURE

 

 

 

 

 

 

 

 

 

AIR ON EVAPORATOR COIL

 

 

 

 

 

 

 

 

 

1,200 CFM

 

 

1,400 CFM

 

 

 

1,600 CFM

 

 

1,800 CFM

 

 

2,000 CFM

 

OF AIR ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB °F

 

 

WB °F

 

 

 

WB °F

 

 

WB °F

 

 

WB °F

 

CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

62

57

72

67

62

57

 

72

67

62

57

72

67

62

57

72

67

62

57

 

 

NET CAP.

 

48.5

45.0

41.0

41.6

49.9

46.3

42.2

42.8

 

51.3

47.6

43.4

44.0

52.4

48.7

44.4

44.9

53.5

49.7

45.3

45.9

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

3.99

3.93

3.87

3.86

4.01

3.95

3.88

3.88

 

4.02

3.96

3.90

3.89

4.04

3.97

3.91

3.91

4.05

3.99

3.92

3.92

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

28.9

36.8

41.0

41.6

31.9

40.5

42.2

42.8

 

34.9

44.1

43.4

44.0

38.0

46.9

44.4

44.9

41.0

49.7

45.3

45.9

85 °F

MBH

 

DryEntering °FBulb

 

83

25.5

33.4

40.3

41.2

27.8

36.4

41.9

42.6

 

30.2

39.4

43.4

44.0

32.7

42.5

44.4

44.9

35.1

45.6

45.3

45.9

 

 

1

 

 

 

80

22.0

30.0

36.9

37.8

23.8

32.4

39.8

40.9

 

25.6

34.8

42.8

43.9

27.3

37.2

44.1

44.9

29.1

39.6

45.3

45.9

 

 

 

 

 

 

77

18.6

26.5

33.4

34.4

19.8

28.3

35.8

36.8

 

20.9

30.1

38.1

39.2

22.0

31.9

38.7

39.6

23.1

33.6

39.4

40.0

 

 

 

 

 

 

74

15.2

23.1

30.0

31.0

15.7

24.3

31.7

32.8

 

16.2

25.4

33.5

34.6

16.7

26.6

33.4

34.3

17.2

27.7

33.4

34.0

 

 

 

 

 

 

71

-

19.7

26.6

27.6

-

20.2

27.7

23.7

 

-

20.8

28.8

29.9

-

21.2

28.1

29.0

-

21.7

27.5

28.0

 

 

 

 

 

 

68

-

16.3

23.2

24.1

-

16.2

23.7

24.7

 

-

16.1

24.1

25.2

-

15.9

22.8

23.7

-

15.7

21.5

22.1

 

 

NET

CAP.

 

 

43.5

41.9

36.3

36.9

46.1

44.4

38.6

39.1

 

48.8

47.0

40.8

41.4

48.6

46.8

40.6

41.2

48.3

46.5

40.4

40.9

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

4.44

4.34

4.32

4.32

4.44

4.34

4.32

4.32

 

4.43

4.33

4.31

4.47

4.37

4.37

4.35

4.35

4.50

4.41

4.38

4.39

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

27.2

35.6

36.3

36.9

30.7

40.1

38.6

39.1

 

34.3

44.7

40.8

41.4

36.8

45.6

40.6

41.2

39.2

46.5

40.4

40.9

95 °F

MBH

 

DryEntering °FBulb

 

83

23.7

32.2

36.3

36.9

26.7

36.1

38.6

39.1

 

29.7

40.0

40.8

41.4

31.5

42.3

40.6

41.2

33.3

44.6

40.4

40.9

 

 

1

 

 

 

80

20.3

28.8

33.1

33.6

22.7

32.1

36.9

37.4

 

25.0

35.4

40.7

41.3

26.2

37.0

40.5

41.1

27.3

38.6

40.4

40.9

 

 

 

 

 

 

77

16.9

25.3

29.7

30.2

18.6

28.0

32.9

33.4

 

20.3

30.7

36.1

36.6

20.8

31.7

35.2

35.8

21.3

32.7

34.4

35.0

 

 

 

 

 

 

74

13.5

21.9

26.3

26.7

14.6

24.0

28.8

29.3

 

15.7

26.0

31.4

32.0

15.5

26.4

29.9

30.5

15.4

26.7

28.4

29.0

 

 

 

 

 

 

71

-

18.5

22.8

23.3

-

19.9

24.8

25.3

 

-

21.4

26.7

27.3

-

21.1

24.6

25.2

-

20.8

22.5

23.0

 

 

 

 

 

 

68

-

15.1

19.4

19.5

-

15.9

20.7

21.3

 

-

16.7

22.1

22.6

-

15.7

19.3

19.9

-

14.8

16.5

17.1

 

 

NET

CAP.

 

 

42.2

39.2

35.7

36.0

44.1

40.9

37.2

37.5

 

45.9

42.6

38.8

39.1

46.4

43.1

39.2

39.5

47.0

43.6

39.7

40.0

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

4.94

4.85

4.81

4.81

4.95

4.85

4.81

4.82

 

4.95

4.86

4.82

4.83

4.98

4.89

4.84

4.85

5.00

4.91

4.87

4.89

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

26.7

34.8

35.7

36.0

30.1

38.1

37.2

37.5

 

33.4

41.5

38.8

39.1

36.1

42.5

39.2

39.5

38.8

43.6

39.7

40.0

105 °F

MBH

 

DryEntering °FBulb

 

83

23.3

31.3

35.3

35.6

26.0

34.9

37.0

37.3

 

28.7

38.4

38.8

39.1

30.8

40.5

39.2

39.5

32.8

42.6

39.7

40.0

 

 

1

 

 

 

80

19.9

27.9

32.0

32.2

22.0

30.8

35.3

35.6

 

24.1

33.8

38.7

39.0

25.5

35.7

39.2

39.5

26.9

37.7

39.7

40.0

 

 

 

 

 

 

77

16.5

24.5

28.6

28.8

17.9

26.8

31.3

31.6

 

19.4

29.1

34.0

34.3

20.2

30.4

33.9

34.2

20.9

31.7

33.7

34.0

 

 

 

 

 

 

74

13.0

21.1

25.1

25.4

13.9

22.8

27.2

27.5

 

14.7

24.4

29.4

29.7

14.8

25.1

28.6

28.9

14.9

25.8

27.8

28.1

 

 

 

 

 

 

71

-

17.7

21.7

22.0

-

18.7

23.2

23.5

 

-

19.8

24.7

25.0

-

19.8

23.3

23.6

-

19.8

21.8

22.1

 

 

 

 

 

 

68

-

14.2

18.3

18.5

-

14.7

19.2

19.4

 

-

15.1

20.0

20.3

-

14.5

17.9

18.3

-

13.9

15.9

16.2

 

 

NET

CAP.

 

 

41.0

36.5

35.0

35.1

42.0

37.3

35.9

35.9

 

43.0

38.2

36.7

36.8

44.3

39.4

37.9

37.9

45.7

40.6

39.0

39.1

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

5.44

5.35

5.29

5.30

5.46

5.37

5.31

5.32

 

5.47

5.39

5.33

5.34

5.49

5.40

5.34

5.35

5.50

5.42

5.35

5.37

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

26.3

33.9

35.0

35.1

29.4

36.1

35.9

35.9

 

32.5

38.2

36.7

36.8

35.4

39.4

37.9

37.9

38.4

40.6

39.0

39.1

115 °F

MBH

 

DryEntering °FBulb

 

83

22.9

30.5

34.3

34.3

25.3

33.7

35.5

35.5

 

27.8

36.9

36.7

36.8

30.1

38.7

37.9

37.9

32.4

40.6

39.0

39.1

 

 

1

 

 

 

80

19.5

27.1

30.8

30.9

21.3

29.6

33.7

33.6

 

23.1

32.1

36.7

36.7

24.8

34.9

37.8

37.9

26.4

36.8

39.0

39.1

 

 

 

 

 

 

77

16.0

23.7

27.4

27.5

17.2

25.6

29.7

29.8

 

18.5

27.5

32.0

32.0

19.5

29.2

32.5

32.6

20.5

30.8

33.1

33.1

 

 

 

 

 

 

74

12.6

20.6

24.0

24.0

13.2

21.5

25.7

25.7

 

13.8

22.9

27.3

27.4

14.2

23.9

27.2

27.3

14.5

24.9

27.1

27.2

 

 

 

 

 

 

71

-

16.8

20.6

20.6

-

17.5

21.6

21.7

 

-

18.2

22.7

22.7

-

18.5

21.9

22.0

-

18.9

21.1

21.2

 

 

 

 

 

 

68

-

13.4

17.2

17.2

-

13.5

17.6

17.6

 

-

13.5

18.0

18.1

-

13.2

16.6

16.6

-

12.9

15.2

15.2

 

 

NET

CAP.

 

 

39.7

33.7

34.3

34.2

39.9

33.6

34.5

34.3

 

40.1

33.9

34.7

34.5

42.2

35.8

36.5

36.3

44.4

37.7

38.4

38.2

 

 

 

MBH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTAL POWER

5.90

5.90

5.80

5.80

6.00

5.90

5.80

5.80

 

6.00

5.90

5.80

5.90

6.00

5.90

5.80

5.90

6.00

5.90

5.80

5.90

 

 

INPUT kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

86

25.9

33.1

34.3

34.2

28.7

34.0

34.5

34.3

 

31.5

35.0

34.7

34.5

34.7

36.4

36.5

36.3

37.9

37.7

38.4

38.2

125 °F

MBH

 

DryEntering °FBulb

 

83

22.4

29.7

33.2

33.0

24.7

32.5

34.0

33.8

 

26.9

35.3

34.7

34.5

29.4

37.0

36.5

36.3

32.0

38.7

38.4

38.2

 

 

1

 

 

 

80

19.0

26.2

29.7

29.5

20.6

28.4

32.2

32.0

 

22.2

30.6

34.6

34.4

24.1

33.2

36.5

36.3

26.0

35.9

38.4

38.2

 

 

 

 

 

 

77

15.6

22.8

26.8

26.1

16.6

24.4

28.1

27.9

 

17.5

25.9

30.0

29.8

18.8

27.9

31.2

31.0

20.0

29.9

32.4

32.2

 

 

 

 

 

 

74

12.2

19.4

22.9

22.7

12.5

20.3

24.1

23.9

 

12.9

21.3

25.3

25.1

13.5

22.6

25.9

25.7

14.1

23.9

26.4

26.2

 

 

 

 

 

 

71

-

16.0

19.4

19.3

-

16.3

20.0

19.9

 

-

16.6

20.6

20.4

-

17.3

20.5

20.4

-

18.0

20.5

20.3

 

 

 

 

 

 

68

-

12.6

16.6

15.9

-

12.2

16.0

15.8

 

-

11.9

16.0

15.8

-

12.0

15.2

15.0

-

12.0

14.5

14.3

1. These capacities are net capacities (the indoor fan heat is deducted). ALL SENSIBLE CAPACITY

Johnson Controls Unitary Products

11

Image 11
Contents Featuring Flexible Light Commercial UnitGeneral Table of Contents Description Standard FEATURES/BENEFITSHigh Altitude Conversion KIT Natural Gas/Propane FIELD-INSTALLED AccessoriesUnit Component Location Model DNA Physical DataMBH Burners Range Ratings COOLING/GAS HeatingRise AIR on WB F Temperature AIR on Evaporator CoilDNA030 Cooling Capacities 2-1/2 TON DNA036 Cooling Capacities 3 TON DNA042 Cooling Capacities 3-1/2 TON AIR on DNA048 Cooling Capacities 4 TONDNA060 Cooling Capacities 5 TON External Static Pressure IWG Model # MTR Side Supply AIR Blower PERFORMANCE1Bottom Supply AIR Blower PERFORMANCE1 External Staic Pressure IWG Model # MTR DNA SPDWET Evaporator Coil ECONOMIZER2 Filter Frame KIT Additional Static Pressure Resistance 4 5 TON DNA048RESISTANCE, IWG Description CFM Factor FLA Amps Voltage CompressorClearances Unit Size DimensionUnit Minimum CLEARANCES1 Unit Dimensions Front & Bottom Typical Slab on Ground Installation D116 Roof Curb DIMENSIONS1 XTG-D-0508 XTG-D-0508 XTG-D-0508 Description Typical Wiring Diagram Notes see ThruMechanical Specifications Unit Cabinet XTG-D-0508 XTG-D-0508 Johnson Controls Unitary Products York Drive Norman, OK