York BP 072 warranty BP072 Heating Capacities, Id Db, Outdoor AIR Temperature F 72% RH, Mbh

Page 18

036-21630-001-B-0904

TABLE 4: BP072 HEATING CAPACITIES

CFM

ID DB

 

CAP &

 

 

 

 

 

 

 

 

 

OUTDOOR AIR TEMPERATURE (°F) (72% RH)

 

 

 

 

 

 

 

 

 

 

 

KW

 

-10

 

 

0

 

 

 

10

 

 

20

 

 

30

 

 

40

 

 

50

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

MBH

 

14.733

 

 

23.633

 

32.534

 

 

41.435

 

50.336

 

59.237

 

 

68.137

 

77.038

 

 

 

 

 

KW

 

4.418

 

 

4.516

 

 

4.614

 

 

4.712

 

4.809

 

 

4.907

 

 

5.005

 

 

5.103

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

70

 

 

MBH

 

13.492

 

 

22.393

 

31.293

 

 

40.194

 

49.095

 

57.996

 

 

66.897

 

75.797

 

 

 

 

KW

 

5.105

 

 

5.203

 

 

5.301

 

 

5.399

 

5.496

 

 

5.594

 

 

5.692

 

 

5.790

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

MBH

 

11.260

 

 

20.161

 

29.062

 

 

37.962

 

46.863

 

55.764

 

 

64.665

 

73.566

 

 

 

 

 

KW

 

5.559

 

 

5.657

 

 

5.755

 

 

5.853

 

5.950

 

 

6.048

 

 

6.146

 

 

6.244

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

MBH

 

16.565

 

 

25.466

 

34.366

 

 

43.267

 

52.168

 

61.069

 

 

69.969

 

78.870

 

 

 

 

 

KW

 

4.043

 

 

4.141

 

 

4.239

 

 

4.337

 

4.434

 

 

4.532

 

 

4.630

 

 

4.728

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2400

 

70

 

 

MBH

 

15.348

 

 

24.249

 

33.149

 

 

42.050

 

50.951

 

59.852

 

 

68.752

 

77.653

 

 

 

 

KW

 

4.737

 

 

4.835

 

 

4.933

 

 

5.031

 

5.128

 

 

5.226

 

 

5.324

 

 

5.422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

MBH

 

13.007

 

 

21.908

 

30.808

 

 

39.709

 

48.610

 

 

57.511

 

 

66.411

 

 

75.312

 

 

 

 

 

KW

 

5.159

 

 

5.257

 

 

5.355

 

 

5.453

 

5.550

 

 

5.648

 

 

5.746

 

 

5.844

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

MBH

 

17.156

 

 

26.057

 

34.958

 

 

43.859

 

52.759

 

61.660

 

 

70.561

 

79.462

 

 

 

 

 

KW

 

3.870

 

 

3.968

 

 

4.066

 

 

4.164

 

4.261

 

 

4.359

 

 

4.457

 

 

4.555

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3000

 

70

 

 

MBH

 

15.915

 

 

24.816

 

33.717

 

 

42.618

 

51.519

 

60.419

 

 

69.320

 

78.221

 

 

 

 

KW

 

4.557

 

 

4.655

 

 

4.753

 

 

4.851

 

4.948

 

 

5.046

 

 

5.144

 

 

5.242

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

MBH

 

13.684

 

 

22.584

 

31.485

 

 

40.386

 

49.287

 

58.188

 

 

67.088

 

75.989

 

 

 

 

 

KW

 

5.011

 

 

5.109

 

 

5.207

 

 

5.305

 

5.402

 

 

5.500

 

 

5.598

 

 

5.696

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE MBH

AND KW

VALUES DO

NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 X KW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 5: SUPPLY AIR BLOWER PERFORMANCE (6 TON BELT DRIVE) - SIDE DUCT APPLICATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

AIR

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE-IWG3

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOW

 

 

0.20

 

 

0.30

 

 

 

0.40

 

 

0.50

 

 

0.60

 

 

 

 

0.70

 

 

 

0.80

 

TONNAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

 

WATTS

RPM

 

WATTS

 

RPM

 

WATTS

RPM

 

WATTS

 

RPM

 

WATTS

 

RPM

 

 

WATTS

 

RPM

 

WATTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3200

1150

 

2325

1182

 

2425

 

1212

 

2525

-

 

-

 

-

 

-

 

 

 

-

 

-

 

-

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3000

1100

 

2010

1129

 

2090

 

1157

 

2150

1185

 

2225

 

1215

 

2290

 

 

1242

 

2360

 

-

 

 

-

 

 

 

2800

1045

 

1700

1074

 

1780

 

1102

 

1850

1131

 

1940

 

1160

 

2025

 

 

1190

 

2075

 

1217

 

2130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

61, 2

 

2600

985

 

1425

1015

 

1475

 

1045

 

1540

1075

 

1630

 

1103

 

1715

 

 

1135

 

1760

 

1163

 

1825

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2400

930

 

1240

958

 

1300

 

990

 

1350

1020

 

1400

 

1051

 

1430

 

 

1081

 

1490

 

1111

 

1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2200

-

 

-

 

905

 

1070

 

933

 

1160

965

 

1210

 

997

 

1250

 

 

1028

 

1285

 

1060

 

1325

 

 

 

2000

-

 

-

 

-

 

-

 

-

 

 

-

919

 

1025

 

950

 

1100

 

 

982

 

1130

 

1014

 

1160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

-

 

-

 

-

 

-

 

-

 

 

-

-

 

-

 

909

 

925

 

 

939

 

1005

 

968

 

 

1030

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

AIR

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE-IWG3

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOW

 

 

0.90

 

 

1.00

 

 

 

1.10

 

 

1.20

 

 

1.30

 

 

 

 

1.40

 

 

 

1.50

 

TONNAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

 

WATTS

RPM

 

WATTS

 

RPM

 

WATTS

RPM

 

WATTS

 

RPM

 

WATTS

 

RPM

 

 

WATTS

 

RPM

 

WATTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3200

-

 

-

 

-

 

-

 

-

 

 

-

-

 

-

 

-

 

-

 

 

 

-

 

-

 

-

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3000

-

 

-

 

-

 

-

 

-

 

 

-

-

 

-

 

-

 

-

 

 

 

-

 

-

 

-

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2800

1245

 

2190

-

 

-

 

-

 

 

-

-

 

-

 

-

 

-

 

 

 

-

 

-

 

-

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

61, 2

 

2600

1193

 

1920

1222

 

1990

 

1250

 

2060

-

 

-

 

-

 

-

 

 

 

-

 

-

 

-

 

 

-

 

 

2400

1142

 

1675

1173

 

1730

 

1205

 

1800

1234

 

1885

 

-

 

-

 

 

 

-

 

-

 

-

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2200

1090

 

1380

1124

 

1450

 

1155

 

1550

1186

 

1640

 

1217

 

1710

 

 

1249

 

1775

 

-

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

1045

 

1175

1077

 

1200

 

1109

 

1275

1140

 

1360

 

1170

 

1460

 

 

1205

 

1545

 

1235

 

1600

 

 

 

1800

998

 

1050

1028

 

1060

 

1058

 

1060

1087

 

1075

 

1118

 

1150

 

 

1148

 

1250

 

1176

 

1360

 

1.230/460/575 Volts

2.For 208 Volts multiply values by 0.95.

3.Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows.

18

Unitary Products Group

Image 18
Contents Single Package Heat Pump Units DescriptionAshrae 90.1-2001 Compliant Table of Contents 072 C00 Product NomenclatureProduct Nomenclature Johnson UNT Controller, DFS, APS, SS Drain Pan Technicoat Condenser Coil & Dirty Filter Switch Hinged Filter Door & Toolless Access Cabinet 036-21630-001-B-0904 Novar ETC-3 Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Cabinet Features FACTORY-INSTALLED Options Unit CutawayFIELD-INSTALLED Accessories 036-21630-001-B-0904 ESP Blower Sound Power RATING1Capacity Ratings Unit CFMBP072 Cooling Capacities 6 TON 1800125F ID DB Outdoor AIR Temperature F 72% RHBP072 Heating Capacities MBHBelt Drive Blower Motor and Drive Data Static ResistancesElectric Heater CFM Limitations Brkr FLANone Tonnage Motor Outlet Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Typical Control WiringUnit Dimensions Front View Unit with Fixed Outdoor AIR/MOTORIZED Damper Rainhood Minimum Clearances Hole Opening Size DIA Used forClearance Typical Applications BP 6 Point Loads Weight Distribution Operating Weights LBSCenter of Gravity Guide Specifications GeneralDescription Indoor Evaporator FAN Assembly Manual Outdoor AIR Damper 036-21630-001-B-0904

BP 072 specifications

The York BP 072 is a prominent model within the York line of rooftop units. Renowned for its efficiency and robust performance, the BP 072 is designed to cater to the needs of commercial applications where reliable heating and cooling are paramount. With a focus on energy efficiency, this model offers optimal performance while minimizing energy consumption, making it a suitable choice for businesses aiming to reduce operational costs.

One of the standout features of the York BP 072 is its advanced scroll compressor technology. This technology not only enhances the unit's efficiency but also ensures quieter operation, thus creating a more comfortable environment for occupants. The compressor's design helps reduce vibration, which contributes to the overall longevity of the unit.

In terms of thermal performance, the BP 072 is engineered with a high-efficiency coil design that maximizes heat exchange. This design plays a crucial role in delivering superior cooling and heating capabilities throughout the year. Furthermore, the unit comes equipped with multiple stages of heating and cooling, ensuring precise temperature control and comfort, regardless of the weather outside.

The BP 072 benefits from York’s commitment to sustainability, featuring environmentally friendly refrigerants that align with modern environmental regulations. The use of these refrigerants not only provides minimal ecological impact but also contributes to energy efficiency, addressing both operational costs and environmental concerns.

Another characteristic that sets the York BP 072 apart is its user-friendly control system. The unit includes an integrated microprocessor-based control that streamlines operation and monitoring. This feature allows facility managers to easily adjust settings, enabling the unit to operate efficiently based on current demand and occupancy levels.

Ease of maintenance is another significant aspect of the BP 072. Designed with accessible components, routine upkeep is simplified, allowing technicians to perform inspections and repairs with minimal disruption to building operations. This focus on serviceability not only extends the life of the unit but also ensures continuous performance.

Overall, the York BP 072 stands out as a reliable and efficient solution for commercial heating and cooling needs. Its advanced features, energy-efficient technologies, and user-friendly characteristics make it an ideal choice for businesses looking to manage their environment effectively while minimizing costs. Whether for new construction or replacement of existing systems, the York BP 072 is a strong contender in today’s competitive market.