United States Stove G9740L, C9740N, A9740N, G9740N Lighting Instructions, Turn OFF GAS to Appliance

Page 12

OPERATING INSTRUCTIONS

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information on the previous page.

2.Turn off all electrical power and open the access door.

3.Turn off the rear burner and set the front burner to low.

4.Push in gas control (knob 1) slightly and turn

clockwise to "OFF".

KNOB 3

 

3. REAR BURNER

 

Meritik MAXITROL

OFF

MIN

 

 

ON

MAX

 

OFF

ON

 

 

 

 

 

IGN

 

 

 

PILOT

 

2. FRONT BURNER

 

1. PILOT

KNOB 1

KNOB 2

 

 

NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't

smell gas, go on to the next step.

PILOT LOCATION

TOP VIEW OF BURNER ASSEMBLY

6.Push in the control (knob 1) all the way and

rotate counter-clockwise to "PILOT". The piezo ignitor will light the pilot as the knob passes "IGN" traveling to the "PILOT". Con tinue to hold the control (knob 1) in for about ten (10) seconds after the pilot is lit. Release knob and it should pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through

6.If the control (knob 1) does not pop up when released, stop and immediately call your ser vice technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control (knob 1) to "OFF" and call your service technician or your gas supplier.

7.Turn gas control (knob1) counter-clockwise

to "ON".

8.Set the front burner (knob 2) to the desired

setting rotating counter-clockwise to

MAX. and clockwise to MIN.

9.Set the rear burner (knob 3) to the desired

setting rotating counter-clockwise to MAX./ ON or MIN.

10.Close access door and turn on electrical power.

TURN OFF GAS TO APPLIANCE

1.Open access door.

2.Set front burner to Min. and turn off the rear burner by depressing knob and rotating clockwise

until stop.

3.Unplug all electric power (optional blower) if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to "OFF". Do not force.

5.Close access door.

12

Image 12
Contents United States Stove Company Table of Contents Important Safety Information Explosion or carbon monoxide poisoningProduct Features FeaturesContents Items Required for Installation Items Required for InstallationCodes Adequate Combustion and Ventilation AIRInstallation Minimum ClearancesGAS Connection Gas ConnectionGAS Pressure Check Rear View of 9740 Vent-Free Gas HeaterLOG Assembly Proper Installation SequenceRemoving Front Screen LOG PositioningFor Your Safety Read Before Lighting For Your SafetyOperating Instructions What to do if YOU Smell GASLighting Instructions Turn OFF GAS to ApplianceMatch Lighting Instructions Checking Flame AppearancePilot Flame Cleaning / Servicing Flame AppearanceFlames Heater Assembly Replacement Parts Parts List for Heater Assembly KEY Description QTYBurner & LOG Assembly Parts List for GAS LOG Assembly Troubleshooting Observed Problem Possible Cause RemedyTroubleshooting Optional F40 Blower KIT Page Limited Warranty Policy HOW to Order Repair Parts or Options United States Stove Company