HP Enterprise File Services WAN Accelerator manual Monitoring Data, To run the RCU in monitor mode

Page 22

To run the RCU in monitor mode

20

IMPORTANT: To specify the HP EFS WAN Accelerator for data warming you must use the HP EFS WAN Accelerator’s Primary IP address. If you do not use the Primary IP address, the HP EFS WAN Accelerator cannot effectively warm the data.

In this example, the RCU client sends the files or directory in c:/data to the target HP EFS WAN Accelerator.

Because data flows through both HP EFS WAN Accelerators, the data store on them is warm with the file data transmitted. A warm HP EFS WAN Accelerator has seen the data before, thus only data that has not been transferred before or has changed, is sent across the WAN.

CIFS transparent prepopulation assures high performance for future data transfers. You can also use it to transfer the data store before HP EFS WAN Accelerators are deployed in their final location.

IMPORTANT: To ensure efficient transparent prepopulation, only prepopulate the HP EFS WAN Accelerator with as much data as the disk can hold.

Monitoring Data

The RCU can monitor client directories (and their subdirectories) for changes. After a change has been detected the RCU performs a mirror, copy, or prepopulation action. The changes can be file updates, file or directory creation and deletion, attribute changes, security changes, and so forth.

• Add the monitor mode arguments to the Run command-line. For example:

rcu /monitor /monitoridlewait 10 /monitormaxwait 300 /mirror

c:\build server1 build1

In this example, the RCU waits for any changes in the c:\build directory, or any subtree of it. After a change is detected, the RCU waits for 10 seconds where no further changes occur, or 300 seconds after the initial change, whichever comes first. When the time limit is reached, the RCU mirrors the client c:\build directory tree and the build1 directory on the server.

NOTE: The RCU cannot monitor an entire hard drive (for example: the c: drive). You can monitor source directories on network shares. For example, the \\localserv\dir directory.

For all client actions other than mirroring, consider making the idle and maximum wait-times long. Otherwise, you might frequently perform large data transfers. While the deployed HP EFS WAN Accelerators significantly reduce the bandwidth required, the data transfers place a load on the client, the HP EFS WAN Accelerators, and the server. For detailed information, see

“/monitoridlewait” on page 29 and “/monitormaxwait” on page 29

2 - INSTALLING AND USING THE RCU

Image 22
Contents HP StorageWorks Enterprise File Services Remote Copy Utility 392364-003Page Contents Chapter HP EFS RCU Commands IndexAbout This Guide IntroductionTypes of Users Organization of This Guide Document Conventions BoldfaceHardware and Software Dependencies Additional ResourcesRelated Reading HP Storage Web Site HP NAS Services Web Site Contacting HPIntroduction HP EFS Remote Copy Utility OverviewFeatures HP EFS RCU DeploymentTransparent Prepopulation HP EFS Remote Copy Utility To install the RCU on a Installing and Using the RCUInstalling the RCU Client and serverModifying the Default RCU Parameters Upgrading from RCU 2.1 toRunning the RCU from the Command-Line Interface Scheduling Tasks for the RCUTo schedule tasks for RCU on a client Copying Data To start the RCU in server mode as a Windows service To copy data Mirroring Data To mirror dataTransparently Prepopulating Cifs Data To run the RCU in monitor mode Monitoring DataCreating Log Files Additional RCU FeaturesRestricting Clients To restrict clientsSpecifying Time Limits Specifying Wild Cards Excluding Files and DirectoriesCopy HP EFS RCU CommandsClient Actions SyntaxParameters MirrorPrepop DescriptionMaxretries Client OptionsExcludepath ExampleServer Options TimeoutMaxretrywait Allowclientip AllowabspathDenyclientip Server ServerdebugMonitoridlewait Monitoring ActionsMonitor MonitormaxwaitLogfile Logging OptionsLogfilemax Logfilenum Global OptionsLogfilename QuietConfigfile CompareaclsRecvbuf ReadtimeoutPort SendbufHP EFS RCU Commands Index RCUIndex