WARNING Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during start-up, normal operation, and after pump shut-off. Stand clear of circulation system equipment during pump start-up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury, or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be set in a position to allow system water to

return back to the pool. Do not change filter control valve position while system pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water (not air or air and water mix) is discharged from the valve. All suction and discharge valves MUST be OPEN when starting the circulation system. Failure to do so could result in severe personal injury and/or property damage.

WARNING Separation Hazard. Failure to follow safety and operation instructions could result in violent separation of pump components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Do not operate pool and spa circulation system if a system component is not assembled properly, damaged, or missing. Do not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body. All suction and discharge valves MUST be OPEN when starting the circulation system.

Failure to do so could result in severe personal injury and/or property damage.

WARNING WARNING

Never operate or test the circulation system at more than 50 PSI.

Fire and burn hazard. Motors operate at high temperatures and if they are not properly isolated from

any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or death. It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns.

WARNING Failure to install according to defined instructions may result in severe personal injury or death.

General Information

Introduction

This manual contains information for the proper installation and operation of the Hayward TriStar Pump Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void

warranty.

Product Benefits

The new TriStar Pump’s advanced fluid dynamic design optimizes the three essential pump elements to deliver superior flow, energy efficiency, and quietness. Plus, the heavy-duty pump and motor construction operates cooler for years of dependability. It is the first to feature a Tri-Lock cam and ramp strainer cover design that closes with less than a quarter turn, and the TriStar’s super-sized, smooth no-rib basket with extra leaf-holding capacity is easy to clean. TriStar has a variety of bases available to seamlessly retrofit to existing filtration systems.

WWW.HAYWARDPOOL.COM

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Image 4
Contents USE only Hayward Genuine Replacement Parts TriStar Pump Replacement GuideDivision Street ELIZABETH, NJ 07207 908 Full RatedUse of non-Hayward replacement parts voids warranty TriStar Pump SeriesUSE only Hayward Genuine Replacement Parts Warranty General InformationIntroduction Product BenefitsInstallation Instructions Maximum Recommended System Flow Rate by Pipe SizeTriStar Pump Series Pump Mounting cont’d Plumbing ElectricalTriStar Pump Series Electrical cont’d Start-Up & OperationPrior to Start-Up Maintenance TriStar Pump Series Starting/Priming the PumpShaft Seal Change Instructions Storage/WinterizationStoring Pump For Winterization USE only Hayward Genuine Replacement Parts Parts Diagram Replacement PartsParts Listing TriStar Pump Series Parts Listing cont’d Pump SKU DetailTroubleshooting Noisy Pump Check For TriStar Pump Series Low Flow Generally, Check For cont’dProduct Registration Please send me more information on these other Hayward Limited WarrantyProducts from Hayward

SP3010EEAZ, SP3210EE, SP3215X20, SP3015EEAZ, SP3210X15 specifications

The TriStar range of pressure and temperature transmitters, specifically the models SP3010EEAZ, SP3010X15AZ, SP3215X20, SP3207X10, and SP3210X15, showcases advanced technologies tailored for precision in industrial applications. These transmitters are engineered to provide accurate readings under a variety of conditions, enhancing the efficiency and reliability of processes.

The SP3010EEAZ is designed for temperature measurement, utilizing a highly sensitive sensor that offers a wide temperature range. Its robust construction makes it ideal for harsh environments, ensuring durability and longevity. This model features advanced signal processing algorithms that minimize noise and improve measurement accuracy. Additionally, it supports multiple output options, allowing for versatile integration into existing systems.

Similarly, the SP3010X15AZ is a versatile pressure transmitter known for its compact design and high-performance characteristics. It employs piezoresistive sensing technology, which ensures quick response times and exceptional stability over time. The SP3010X15AZ is capable of measuring both gauge and absolute pressures, making it suitable for various applications across different industries. Its digital display provides real-time readings, enhancing operational oversight.

The SP3215X20 extends the range of capabilities with its dual functionality, measuring both pressure and temperature. Featuring an intuitive user interface, it allows for straightforward calibration and adjustment. This model incorporates advanced diagnostics, which can alert users to potential issues, ensuring that system integrity is maintained.

On the other hand, the SP3207X10 is a specialized transmitter with a focus on high-pressure applications. Equipped with reinforced housing and advanced sealing technologies, it offers unparalleled resistance to extreme conditions. Its design prioritizes safety, making it a reliable choice for critical processes.

Lastly, the SP3210X15 combines cutting-edge technology with user-friendly features. Its modular design allows for easy maintenance and upgrades, making it adaptable for evolving industrial needs. With high accuracy and a broad operational range, this model is perfect for applications requiring precise pressure and temperature monitoring.

In summary, the TriStar SP series transmitters exemplify innovation in pressure and temperature measurement. Their combination of advanced sensor technologies, user-centric designs, and robust construction positions them as ideal solutions for industrial applications, ensuring enhanced performance and reliability across various operational settings.