Make sure that you check the rating plate and combination gas control on the

WHAT TO DO IF YOU SMELL GAS

water heater to be certain that the type of gas being supplied corresponds with

• Do not try to light any appliance.

the marking on the rating plate and combination gas control.

• Do not touch any electrical switch; do not use any

 

A sacrificial anode is used to extend tank life. The removal of this anode, for

telephone in your building.

• Immediately call your gas supplier from a neighbor’s

any reason, will nullify the warranty. In areas where water is unusually active,

telephone. Follow the gas supplier’s instructions.

an odor may occur at the hot water faucet due to a reaction between the

• If you cannot reach your gas supplier, call the fire

sacrificial anode and the impurities in the water. If this should happen, an

department.

alternative anode may be purchased from the supplier that installed this water

 

heater. This will minimize the odor while protecting the tank. Additionally, the

WARNING

water heater should be flushed with appropriate dissolvers to eliminate any

bacteria.

DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE

NOT CERTAIN OF THE FOLLOWING:

 

INSTALLATION

• Liquefied petroleum gases/propane gas and natural gas have an

Locating The Water Heater

odorant added by the gas supplier that aids in detection of the gas.

• Most people recognize this odor as a “sulfur” or “rotten egg” smell.

 

 

 

WARNING

• Other conditions, such as “odorant fade” can cause the odorant to

 

diminish in intensity, or “fade”, and not be as readily detectable.

Water heaters are heat producing appliances. To avoid damage or injury there shall

be no materials stored against the water heater or vent-air intake system and

• If you have a diminished sense of smell, or are in any way unsure of

proper care shall be taken to avoid unnecessary contact (especially by children) with

the presence of gas, immediately contact your gas supplier from a

the water heater and vent-air intake components. UNDER NO CIRCUMSTANCES

neighbor’s telephone.

SHALL FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THIN-

• Gas detectors are available. Contact your gas supplier or plumbing

NER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER,

professional for more information.

VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION FROM WHICH FUMES

 

COULD REACH THE WATER HEATER OR VENT-AIR INTAKE SYSTEM.

This water heater must be located in an area where leakage of the tank, water

 

 

line connections, or the combination temperature and pressure relief valve will

This water heater shall NOT be installed in any location where gasoline or

not result in damage to the area adjacent to the water heater or to lower floors

flammable vapors are likely to be present, unless the installation is such to

of the structure. When such locations cannot be avoided, a suitable drain pan

eliminate the probable ignition of gasoline or flammable vapors.

must be installed under the water heater. The drain pan must be no greater

 

 

than 1-½ inches (3.8 cm) deep and have a minimum length and width of at

The location of this water heater is of the utmost importance. Before installing

least 4 inches (10.2 cm) measured from the jacket of the water heater. The

this water heater, you should read the Installation section of these instructions.

drain pan, as described above, can be purchased from your plumbing

DO NOT locate the water heater where water lines could be subjected to

professional. The drain pan must be piped to an adequate drain. The piping

freezing temperatures. Make sure the cold water pipes are not located directly

must be at least 3/4 inch (1.9 cm) in diameter and pitched for proper

above the gas control so that condensate during humid weather does not drip

drainage.

on the controls.

 

It is recommended that a minimum clearance of 4 inches (10.2 cm) be

 

 

Water heater corrosion and component failure can be caused by the heating

provided on the side of the water heater for servicing and maintenance of the

and breakdown of airborne chemical vapors. Examples of some typical

combination temperature and pressure relief valve.

compounds that are potentially corrosive are: spray can propellants, cleaning

 

solvents, refrigerator and air conditioning refrigerants, swimming pool chemicals,

MINIMUM CLEARANCES

calcium and sodium chloride, waxes and process chemicals. These materials

are corrosive at very low concentration levels with little or no odor to reveal

 

their presence. NOTE: DAMAGE TO THE WATER HEATER CAUSED BY

WARNING

EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE

Failure to adhere to these installation and operating instructions

WARRANTY. DO NOT OPERATE THE WATER HEATER IF EXPOSURE

may create a hazard to life and property and will nullify the

HAS OR WILL OCCUR.

DO NOT STORE ANY POTENTIALLY

warranty.

CORROSIVE COMPOUNDS IN THE VICINITY OF THE WATER HEATER.

 

For exact venting specifications, please consult the Venting section, located on

This installation shall allow access to the front of the water heater and adequate

page 3, of these Installation and Operating Instructions.

clearance shall be provided for servicing and operating this water heater. The

 

 

water heater may be installed on either a combustible or non-combustible

 

WARNING

floor. If the water heater is to be installed directly on carpeting, it shall be

 

installed on top of a metal or wood panel (or equivalent) extending beyond

Liquefied petroleum gases/propane gas are heavier than air and will remain at floor

level if there is a leak. Basements, crawl spaces, closets and areas below ground level

the full width and depth of the appliance by at least 3 inches (7.6 cm) in any

will serve as pockets for accumulation of leaking gas. Before lighting, smell all around

direction or, if the appliance is to be installed in an alcove or closet, the entire

the appliance area for gas. Be sure to smell next to the floor.

floor shall be covered by the panel.

2

Image 2
Contents General Information Table of ContentsGAS Water Heater Telephone in your building Locating The Water HeaterMinimum Clearances Not Certain of the FollowingWater Connections VentingCombustion AIR Supply Sheet metal screws providedGAS Connections Being Certain IT is Filled with WaterTo convert from natural gas to LP gas Match or Open Flame for TestingGAS Conversion Instructions To convert from LP to natural gasLighting Instructions For Your Safety Read Before LightingWhat to do if YOU Smell GAS To Fill the Water HeaterBurner Flame Check Thermostat AdjustmentMaintenance State of California NoticeValve seats properly without leaking and operates freely Typical Installation VentingOr property damage

MFH-I&S-02 specifications

The Lochinvar MFH-I&S-02 is a sophisticated Modular Floor Heat Integrated System known for its innovative design and efficiency in residential and commercial heating applications. As part of Lochinvar's commitment to providing high-performance solutions, the MFH-I&S-02 incorporates a variety of advanced technologies and characteristics that set it apart in the market.

One of the main features of the MFH-I&S-02 is its modular design, which allows for flexible installation options. This system can be easily tailored to meet the specific heating needs of any space, ensuring optimal comfort and energy efficiency. The modular approach not only simplifies installation but also enhances the system's versatility, making it suitable for both new constructions and retrofitting in existing buildings.

The MFH-I&S-02 employs an innovative heat exchanger that maximizes thermal efficiency. With a stainless steel construction, the heat exchanger is designed to withstand high temperatures and pressures, ensuring durability and longevity. This high-efficiency design translates to lower energy consumption, leading to cost savings for the end-user and a reduced carbon footprint.

In addition to its advanced heat exchanger, the MFH-I&S-02 includes smart controls and monitoring capabilities. These features enable users to easily manage their heating system through intuitive interfaces, whether via a wall-mounted display or a smartphone app. This connectivity allows for real-time monitoring and adjustments, facilitating proactive maintenance and optimization of heating performance.

The MFH-I&S-02 also utilizes variable speed technology in its pumps and fans, enhancing energy efficiency further. By adjusting operating speeds based on demand, the system minimizes unnecessary energy use while maintaining consistent heating. This adaptability not only improves comfort levels but also significantly contributes to overall system efficiency.

Furthermore, with a focus on sustainability, the MFH-I&S-02 is designed to work seamlessly with renewable energy sources, such as solar thermal systems. This integration capability allows it to maximize energy use from renewable sources, aligning with modern energy goals and regulations.

In summary, the Lochinvar MFH-I&S-02 is a cutting-edge heating solution that combines modular design, high-efficiency heat exchange, smart technology, and renewable energy compatibility. Its advancements in engineering and user-centered features make it an ideal choice for those seeking an effective and flexible heating system in today's energy-conscious environment.