Lochinvar 51 - 211 manual Please read before proceeding, Boiler service and maintenance

Page 3

User’s Information Manual

Please read before proceeding

NOTICE

The Knight Wall Mount Installation and

Operation Manual along with the Knight

 

Wall Mount Service Manual are for use

 

only by a qualified heating installer/service

 

technician. Refer only to this User’s

 

Information Manual for your reference.

 

Improper installation, adjustment,

 

alteration, service or maintenance can

 

cause property damage, personal injury

 

(exposure to hazardous materials) or loss

 

of life. Installation and service must be

 

performed by a qualified installer, service

 

agency or the gas supplier (who must

 

read and follow the supplied instruction

 

before installing, servicing, or removing

 

this boiler. This boiler contains materials

 

that have been identified as carcinogenic,

 

or possibly carcinogenic, to humans).

Boiler service and maintenance –

To avoid electric shock, disconnect electrical supply before performing maintenance.

To avoid severe burns, allow boiler to cool before performing maintenance.

Boiler operation –

• Do not block flow of combustion or ventilation air to

the boiler. This boiler is equipped with a control which

will automatically shut down the boiler should air or

vent be blocked. If vent or air blockage is easily

accessible and removable, remove it. The boiler should

attempt to restart. If blockage is not obvious or cannot

be removed, have the boiler and system checked by a

qualified service technician.

• Should overheating occur or gas supply fail to shut off,

do not turn off or disconnect electrical supply to the

circulator. Instead, shut off the gas supply at a location

NOTICE

￿WARNING

When calling or writing about the boiler

Please have the boiler model and serial number from the boiler rating plate.

Consider piping and installation when determining boiler location.

Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee.

Factory warranty (shipped with unit) does not apply to units improperly installed or improperly operated.

Failure to adhere to the guidelines on this page can result in severe personal injury, death, or substantial property damage.

external to the appliance.

• Do not use this boiler if any part has been under water.

The possible damage to a flooded appliance can be

extensive and present numerous safety hazards. Any

appliance that has been under water must be replaced.

Boiler water –

Thoroughly flush the system (without boiler connected) to remove sediment. The high-efficiency heat exchanger can be damaged by build-up or corrosion due to sediment.

Do not use petroleum-based cleaning or sealing compounds in the boiler system. Gaskets and seals in the system may be damaged. This can result in substantial property damage.

Do not use “homemade cures” or “boiler patent medicines”. Serious damage to the boiler, personnel, and/or property may result.

Continual fresh make-up water will reduce boiler life. Mineral buildup in the heat exchanger reduces heat transfer, overheats the stainless steel heat exchanger, and causes failure. Addition of oxygen carried in by makeup water can cause internal corrosion. Leaks in boiler or piping must be repaired at once to prevent makeup water.

Freeze protection fluids –

NEVER use automotive antifreeze. Use only inhibited propylene glycol solutions, which are specifically formulated for hydronic systems. Ethylene glycol is toxic and can attack gaskets and seals used in hydronic systems.

3

Image 3
Contents User’s Information Manual Models 51 Contents Please read before proceeding Boiler service and maintenancePrevent combustion air contamination Products to avoidAreas likely to have contaminants Maintenance schedule Service technician Owner maintenanceSee pages 6 8 for detailed instructions Fill condensate trap with water Maintenance scheduleCondensate disposal 1Condensate TrapCheck air vents Operating instructions Installer Smart System control moduleUser Temperature Units Night Setback OverrideSpace heating SH1, SH2, SH3 and tank set points Call for Heat Smart System control module Dial Function User’s Information Manual

51 - 211 specifications

Lochinvar 51-211 is a notable model in the realm of high-performance heating solutions, designed to efficiently meet commercial and residential hot water demands. This innovative water heater stands out due to its capacity, advanced technologies, and energy efficiency, making it a preferred choice for many.

One of the primary features of the Lochinvar 51-211 is its impressive output. With a 211,000 BTU input and a robust design, it is capable of delivering a substantial amount of hot water quickly, which is essential in applications where hot water demand fluctuates significantly. This unit is particularly suitable for large residential homes, restaurants, and other commercial settings where high-volume hot water is critical.

The Lochinvar 51-211 incorporates cutting-edge technology to optimize its performance. It features a stainless steel heat exchanger that not only enhances durability but also improves heat transfer efficiency. This construction provides not only longevity but also minimizes maintenance needs over the lifespan of the unit. Additionally, its smart control system allows for precise temperature control and monitoring, ensuring that users can easily customize settings according to their needs.

Energy efficiency is a cornerstone of the Lochinvar brand, and the 51-211 model is no exception. It achieves a high Energy Factor (EF), which translates to lower energy costs and reduced environmental impact. This unit is also designed to meet stringent efficiency standards, making it an ideal option for environmentally conscious consumers.

Another characteristic of the Lochinvar 51-211 is its versatility in installation. It can be installed in various configurations, allowing for flexible integration into existing systems. Furthermore, its compact design means it can fit into tight spaces without compromising functionality, making it perfect for urban settings where space is often a premium.

Safety features are also a priority in the design of the Lochinvar 51-211. The unit incorporates built-in safeguards, including flue gas monitoring and a vent system designed to prevent backdrafts, ensuring reliable and safe operation for users.

In summary, the Lochinvar 51-211 water heater combines high BTU output, advanced stainless steel technology, excellent energy efficiency, versatile installation options, and safety features. These attributes make it a top choice for anyone in need of a dependable and efficient hot water solution. With Lochinvar’s commitment to quality, users can feel confident that this unit will provide consistent performance for years to come.