BENDIX BW1811 manual AD-IPDI Drop in AIR Dryer Model, General

Page 2

FEEDBACK

LINE

DISCHARGE LINE

SUPPLY

 

RES.

HOLSET COMPRESSOR

FIGURE A

HOLSET TYPE E & QE COMPRESSORS - NO AIR DRYER

STANDARD AD-IPAIR

SPECIAL DISCHARGE

PORT FTG. W/

FEEDBACK LINE

CONNECTIONCHECK VALVE

HOLSET

COMPRESSOR

DRYER

SUPPLY

RES.

FEEDBACK LINE

DISCHARGE

PORT

LOWER

MTG. BRKT.

(PARTIAL) FEEDBACK LINE

SPECIAL DISCHARGE

PORT FTG. W/

FEEDBACK LINE

CONNECTION END COVER

BOTTOM VIEW

FIGURE 2 - AD-IPDI DROP IN AIR DRYER FOR HOLSET

COMPRESSORS

AD-IPDI “DROP IN” AIR DRYER MODEL

In addition to the standard AD-IPair dryer, the Bendix® AD-IPDI (Drop In) air dryer is also offered. It is a specialized version designed especially for air systems that use either the Holset (Cummins) Type E or QE air compressor. These Holset compressors utilize an unusual unloading system that requires that air pressure remain in the discharge line during the entire unloaded cycle of the compressor. To accomplish this, Holset compressors rely on air “feedback” from the supply reservoir as shown in Figure 3B. When an air dryer is installed the direct “feedback” from the supply reservoir is interrupted and an alternate source for “feedback” pressure must be provided. A standard AD-IPair dryer can be installed, however a separate “feedback” line with a single check must be installed as shown in Figure 3C.

The AD-IPDI drop in air dryer model incorporates the feedback line and single check as an integral part of the dryer and eliminates the need for these components as shown in Figures 2 & 3C.

W/CHECK VALVE

FIGURE B

STANDARD AD-IPAIR DRYER AND

HOLSET TYPE E & QE COMPRESSORS

HOLSET

COMPRESSOR

AD-IPDI DROP IN AIR

SUPPLY

DRYER W/FEEDBACK

RES.

LINE & CHECK VALVE

 

FIGURE C

AD-IPDI DROP IN AIR DRYER AND

HOLSET TYPE E & QE COMPRESSORS

FIGURE 3 - AD-IPAIR DRYER AND HOLSET TYPE E & QE

COMPRESSORS

OPERATION

GENERAL

The AD-IPair dryer alternates between two operational modes or “cycles” during operation: the Charge Cycle and the Purge Cycle. The following description of operation is separated into these “cycles” of operation.

CHARGE CYCLE (refer to Figure 4)

When the compressor is loaded (compressing air) compressed air, along with oil, oil vapor, water and water vapor flows through the compressor discharge line to the supply port of the air dryer body.

As air travels through the end cover assembly, its direction of flow changes several times, reducing the temperature, causing contaminants to condense and drop to the bottom or sump of the air dryer end cover.

After exiting the end cover, the air flows into the desiccant cartridge. Once in the desiccant cartridge air first flows through an oil separator located between the outer and inner shells of the cartridge. The separator removes water in liquid form as well as liquid oil and solid contaminants.

2

Image 2
Contents SD-08-2414 Function/ConnectionAD-IPDI Drop in AIR Dryer Model GeneralAD-IPINTEGRAL Purge AIR Dryer Charge Cycle Turbo Cutoff Feature Refer to Figure Preventive Maintenance Operation & Leakage Tests Side View Weatherproof Accordian TOP ViewMaintenance Kits Available Rebuilding the AD-IPAIR DryerDisassembly AD-IPAIR Dryer RemovalCleaning & Inspection Assembly34 35 36 DLU Style Purge Valve Old Style AD-IP End Cover Vertical Delivery Check Valve Retrofitting the AD-IPAIR Dryer AD-IPAIR Dryer InstallationTotal Vehicle Reservoir Volume Requirement Vehicle Application RequirementsLocating AD-IPAIR Dryer on Vehicle Connecting the AIR LinesVehicle Preparation Compressor Discharge LineStandard AD-IPAir Dryer Refer to B Installing AD-IPAIR Dryer with Holset Compressor GeneralPurge Exhaust Line AD-IPDI Drop In Air Dryer Model Refer to CTesting the AD-IPAIR Dryer Wiring Remote Power & Local GroundAD-IPAIR Dryer Troubleshooting Chart Perform tests 1 to 6 in the order presentedAD-IPAIR Dryer Troubleshooting Chart Feedback Line Typical Drop-In Air Dryer End Cover Unloaded for a minimum of 30 seconds. This AD-IPAIR Dryer Troubleshooting Chart Check Valve Preventative Maintenance Section AD-IPAIR Dryer Troubleshooting Chart Low Air Use High Air UseAdditional Troubleshooting Information Conventional Supply System Integral Purge AIR DryerComplaints Common to the Charging & AIR Supply System Complaint Can Not Build System PressureTests Common to More than ONE Complaint Discharge plugged or restricted