Lochinvar EGS-I&S-01 Temperature and Pressure Relief Valve, General Information Features

Page 3

EGS-I&S-01

TEMPERATURE AND PRESSURE

RELIEF VALVE

WARNING

Keep clear of the combination temperature and pressure relief valve discharge line outlet. The discharge may be hot enough to cause scald injury. The water is under pressure and may splash.For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements of the Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 and the Standard CAN1-4.4 Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves. The combination temperature and pressure relief valve must be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater. The combination temperature and pressure relief valve must also have an hourly rated temperature steam BTU discharge capacity not less than the hourly rating of the water heater. The supplied combination temperature and pressure relief valve, when properly installed and unrestricted, will discharge the maximum input produced by a 240°F (116°C) boiler supply temperature. A lower boiler supply temperature will reduce the input required to be discharged in the event of excessive potable water temperatures.

Install the combination temperature and pressure relief valve into the opening provided and marked for this purpose on the water heater.

Some models may already be equipped or supplied with a temperature and pressure relief valve. Verify that the combination temperature and pressure relief valve complies with local codes. If the temperature and pressure relief valve does not comply with local codes, replace it with one that does.

NOTICE

If the boiler takes longer to heat up from a cold start than the water availability as noted above, hot water shortage may occur.

Hot water availability is based off drawing 80% of the heated tank volume at 4 gallons per minute flow rate.

The maximum heat transfer through the coil (heat input) of the water heater at 240°F boiler water supply temperature and 210°F potable water temperature is 94,100 Btu/hr for residential models and 180,300 Btu/ hr for commercial models. Potable water temperature is limited to below 210 °F and nominal water- containing capacity is below 120 gallons for all single- wall indirect models.

Accordingly, per Part HLW-101.2, Section IV of the ASME Boiler and Pressure Vessel Code, all Lochinvar Single-wall Indirect products are exempted from

compliance with the code.

GENERAL INFORMATION

FEATURES

This water heater contains the following features:

HEAT EXCHANGER — The heat exchanger (coil) has 1" NPT female fittings.

These water heaters with single-wall heat exchangers meets the Uniform Plumbing Code for installation in all potable water systems provided that:

The boiler water (including additives) is practically non-toxic, having toxicity rating of class of 1 as listed in Clinical Toxicology of Commercial Products.

The boiler water pressure is limited to maximum 30 psig by approved relief valve.

The heat transfer medium is potable water or contains only substances that are recognized as safe by the U.S. Food and Drug Administration (FDA).

The pressure of the heat transfer medium is maintained less than the normal minimum operating pressure of the potable water system.

The equipment is permanently labeled to indicate that only additives recognized as safe by the FDA shall be used in the heat transfer medium.

3

Image 3
Contents Table of Contents EGS-I&S-01 General Information Features Temperature and Pressure Relief ValveImportant Decisions Required Before Installation Sizing PRE-INSTALLATIONAnswer System Zone Control Domestic HOT Water PriorityComponent Location Instructions for Potable Connections Water ConnectionsInstructions for Boiler Connections Connect Water Boiler Supply PipingConnect Steam Boiler Supply Piping Sequence of Operations Fill Boiler SystemElectrical Connections Operating Instructions System START-UPScald Relationships Water Temperature AdjustmentTo inspect or replace an anode MaintenanceEGS-I&S-01 Problem Cause Solution Trouble Shooting Guide

EGS-I&S-01 specifications

Lochinvar EGS-I&S-01 is a state-of-the-art heating solution designed to provide efficient and reliable heating for commercial and industrial applications. This advanced equipment incorporates innovative technologies that allow it to deliver superior performance while maintaining environmental sustainability.

One of the key features of the Lochinvar EGS-I&S-01 is its high-efficiency design. It utilizes next-generation condensing technology, which extracts maximum heat from the combustion process. This results in lower greenhouse gas emissions and reduced energy consumption, making the system not only cost-effective but also environmentally friendly. The EGS-I&S-01 boasts an impressive thermal efficiency rating, ensuring that energy is used effectively and reducing the overall operating costs for businesses.

The heating unit is equipped with a smart control system that enhances its operational efficiency. This control system allows for precise temperature regulation, remote monitoring, and advanced diagnostics. Users can modify settings based on specific requirements, optimizing performance while ensuring comfort in the designated space. This level of control also helps in identifying potential issues before they escalate, reducing downtime and maintenance costs.

Another significant characteristic of the Lochinvar EGS-I&S-01 is its versatility. Designed for a wide range of applications, it can efficiently serve different facilities, from large commercial buildings to smaller industrial operations. The modular design allows for easy scalability, enabling businesses to expand their heating capacity as needed without major overhauls.

Safety and reliability are paramount in the design of the EGS-I&S-01. It comes equipped with multiple safety features, including flame monitoring, pressure controls, and temperature sensors. These features ensure that the system operates within safe parameters, providing peace of mind for users.

Moreover, the Lochinvar EGS-I&S-01 is built with durable materials that withstand harsh operating conditions, resulting in a long-lasting investment. With low maintenance requirements, businesses benefit from uninterrupted service and reduced operational disruptions.

In summary, the Lochinvar EGS-I&S-01 represents a significant advancement in heating technology. Its combination of high efficiency, smart controls, versatility, safety features, and durability make it an excellent choice for commercial and industrial applications. With ongoing research and development, Lochinvar continues to push the boundaries of heating solutions, ensuring clients benefit from cutting-edge technologies that drive performance and sustainability.