Lochinvar SIT030, SIT119 operation manual 1Piping Diagram Zoned with Circulators

Page 7

Installation & Operation Manual

3 Boiler side piping (continued)

Figure 3-1Piping Diagram Zoned with Circulators

 

 

ZONE #1

PRESSURE

PRESSURE

REDUCING VALVE

GAUGE

BACKFLOW

 

 

PREVENTER

 

 

MAKE UP WATER

SYSTEM SUPPLY

 

 

SENSOR

 

 

(WHEN USED)

AIR SEPARATOR

 

ZONE #2 ZONE #3 ZONE #4

ZONE CIRCULATORS

(TYPICAL)

EXPANSION

 

 

 

TANK

 

 

 

NOT TO EXCEED 4 PIPE DIA.

 

HOT

OR A MAXIMUM OF 12" APART

 

WATER

DRAIN POINT

 

 

OUT

Y-STRAINER

 

 

(TYPICAL)

 

ANTI-SCALD

 

 

BALL VALVE

 

 

MIXING VALVE

FLOW CHECK

 

 

(TYPICAL)

 

COLD

 

VALVE

 

BOILER

 

WATER

 

IN

CIRCULATOR

 

 

 

 

 

 

RELIEF VALVE

 

 

 

TANK SENSOR/

 

 

 

AQUASTAT

UNION

 

 

 

(TYPICAL)

 

 

 

TEMPERATURE /

 

 

 

PRESSURE

 

 

RECIRCULATION

GAUGE

 

 

 

 

PUMP

DRAIN

 

 

 

 

CHECK VALVE

PRESSURE

SOLUTION

SQUIRE

DRAIN

RELIEF VALVE

BOILER

 

( FIELD SUPPLY )

NOTICE

NOTICE

Please note that these illustrations are meant to show system piping concept only, the installer is responsible for all equipment and detailing required by local codes.

Please note that the installer is responsible for ensuring DHW prioritization when piped as a zone.

7

Image 7
Contents Models SIT030 SIT119 Installation & Operation ManualContents Indirect water heater operation Please read before proceedingComponent Materials General informationOperating restrictions Single-wall heat exchangerWater Chemistry Requirements Pre-installationLocating the tank Recommended clearancesBoiler side piping Pressure Drop ChartPressure Drop Values 1Piping Diagram Zoned with Circulators 2Piping Diagram Zoned with Valves 3Knight Boiler Primary / Secondary Piping 4Multiple Tank Connections Multiple tank domestic water piping Domestic side tank pipingBasic domestic piping Domestic water piping for distant fixturesStandard Installation Install drain valveSIT050 105,000 SIT065 200,000 SIT080 SIT119 Btu/hr2Recommended Domestic Water Piping Connect tank sensor WiringIndirect water heater sensor setup Knight boiler Install tank sensor2Wiring for Zone Control Start-up and check-out To Fill the Water Heater MaintenanceMaintenance Schedule Homeowner monthly maintenance to includePerformance data 110 How to properly Size Your Indirect Water HeaterEstimate your peak hour demand as follows Fixture Count GuideFirst Hour Rating 180F Boiler Loop Water Knight Boiler First Hour Rating 180F Boiler Loop Water Universal Sizing First Hour Rating 200F Boiler Loop Water Universal Sizing

SIT030, SIT119 specifications

Lochinvar is a renowned manufacturer of high-efficiency heating solutions, including a range of commercial and residential boilers. Among their offerings are the Lochinvar SIT119 and SIT030 models, which exemplify the brand's commitment to innovation and efficiency in modern heating systems.

The Lochinvar SIT119 is designed for medium to large residential applications, boasting a powerful heating capacity. This model features a robust stainless steel heat exchanger that not only enhances durability but also promotes optimal heat transfer. As part of Lochinvar’s commitment to energy efficiency, the SIT119 incorporates advanced features such as a modulating burner system that adjusts the flame output based on the heating demand, resulting in lower energy consumption and reduced operational costs.

In addition to its efficiency, the SIT119 is equipped with user-friendly controls that allow homeowners and technicians to easily manage and monitor the system. Its intuitive digital display provides real-time information on system performance and diagnostic capabilities, facilitating maintenance and troubleshooting. Furthermore, the SIT119’s compact design enables versatile installation options, making it suitable for various residential spaces.

On the other hand, the Lochinvar SIT030 is tailored for smaller residential applications. Despite its smaller size, it doesn’t compromise on performance or efficiency. This model also features a high-quality stainless steel heat exchanger, ensuring longevity and consistent heating performance. Like the SIT119, the SIT030 utilizes a modulating burner system to optimize energy use, making it an environmentally friendly choice for homeowners seeking effective heating solutions.

One notable characteristic of the SIT030 is its low NOx emission design, which aligns with contemporary environmental standards and helps reduce the carbon footprint associated with heating. Additionally, both models support easy integration with existing heating systems and can be paired with renewable energy sources, such as solar thermal systems, maximizing their efficiency and sustainability.

In summary, the Lochinvar SIT119 and SIT030 models stand out in the heating market, combining advanced technologies with high efficiency and user-friendly features. Their stainless steel construction, modulating burners, compact design, and emissions compliance make them excellent choices for homeowners looking to invest in reliable and eco-conscious heating solutions. With these models, Lochinvar continues to lead in producing innovative products that meet the evolving demands of the heating industry.