Lochinvar SIT119, SIT030 Maintenance Schedule, Homeowner monthly maintenance to include

Page 18

Installation & Operation Manual

7 Maintenance

The Lochinvar SIT series indirect water heater is an extremely simple device and as such requires very little maintenance. There are, however, several items which should be checked out on an annual or as needed basis to ensure a reliable supply of hot water:

*Make sure that the rest of the boiler and domestic water piping is free of leaks.

*If there is an oil lubricated circulator in the system, make sure it is lubricated as called for by the circulator manufacturer.

*Make sure that the boiler is maintained in accordance with the boiler manufacturer’s instructions.

*If a water treatment system is required to keep the water chemistry within the parameters shown in Table 2A (see Section 2 - Pre-Installation), make sure that this system is properly maintained.

Maintenance Schedule

Annual service by a qualified service technician should include the following:

Any procedure required by local codes.

Verify system pressure. Air venting procedure may require adding water to bring boiler system up to pressure, typically 12 psig.

Manually operate T&P relief valve at least once a year. This will release some hot water.

Before operating a T&P relief valve, make ￿ WARNING sure no one is in front of or around the

T&P relief valve discharge piping. Hot discharge water can cause severe personal injury or substantial property damage.

Move operating lever to open position for a few seconds and then move it back, allowing it to snap closed. After the T&P relief valve is operated, if it continues to release water, close the cold water inlet to the water heater immediately. Follow the draining instructions, and replace the T&P relief valve. If the T&P relief valve weeps periodically, it may be due to thermal expansion. Do not plug the T&P relief valve or discharge piping.

Plugging the T&P relief valve or discharge ￿ DANGER piping can cause excessive pressure in the

water heater, resulting in severe personal injury, death, or substantial property damage.

Follow instructions on circulator to oil, if required.

Check mixing valve, valves, pipes, and fittings for leaks.

Check function of the field-installed controls and valves. See component manufacturer’s instructions.

Review homeowner’s maintenance responsibilities and their frequencies, including any not listed in the following section.

Homeowner monthly maintenance to include:

Visually check valves, pipes, and fittings for leaks. Call a qualified service technician to repair leaks.

To Fill the Water Heater

1.Close the water heater drain valve by turning the knob clockwise.

2.Open the cold water supply shutoff valve.

3.Open several hot water faucets to allow air to escape from the system.

4.When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check for water leaks at the water heater drain valve, combination temperature and pressure relief valve and the hot and cold water connections.

Water from opened drain valves, unions and ￿ WARNING other connections may be extremely hot.

To avoid severe personal injury, death, or substantial property damage:

- Tighten all drain hose connections.

- Direct hot water away from all persons.

To Drain the Water Heater

Should it become necessary to completely drain the water heater, be sure to follow the steps below:

1.Disconnect the power supply to the heat source. Consult the plumbing professional or electric company in your area for service.

2.Close the cold water supply shutoff valve.

3.Open the drain valve on the water heater.

4.Open a hot water faucet to allow air to enter the system.

Drain the water heater if it will be shut off and exposed to freezing temperatures. Freezing water will expand and damage the water heater.

If boiler water contains sufficient antifreeze, then only the domestic water needs to be drained.

If boiler water does not contain sufficient antifreeze, the boiler water and the domestic water must be drained.

If antifreeze is used in the boiler water, check concentration. Boiler water (including additives) must be practically non-toxic, having a toxicity rating or class of 1, as listed in the “Clinical Toxicology of Commercial Products”. A maximum 50/50 mixture of inhibited propylene glycol is recommended. Follow the antifreeze manufacturer’s instructions.

Do not use automotive, ethylene glycol ￿ WARNING or petroleum-based antifreeze. Do not use

any undiluted antifreeze. This can cause severe personal injury, death, or substantial property damage.

18

Image 18
Contents Installation & Operation Manual Models SIT030 SIT119Contents Please read before proceeding Indirect water heater operationSingle-wall heat exchanger General informationOperating restrictions Component MaterialsRecommended clearances Pre-installationLocating the tank Water Chemistry RequirementsPressure Drop Chart Boiler side pipingPressure Drop Values 1Piping Diagram Zoned with Circulators 2Piping Diagram Zoned with Valves 3Knight Boiler Primary / Secondary Piping 4Multiple Tank Connections Domestic water piping for distant fixtures Domestic side tank pipingBasic domestic piping Multiple tank domestic water pipingInstall drain valve Standard InstallationBtu/hr SIT050 105,000 SIT065 200,000 SIT080 SIT1192Recommended Domestic Water Piping Install tank sensor WiringIndirect water heater sensor setup Knight boiler Connect tank sensor2Wiring for Zone Control Start-up and check-out Homeowner monthly maintenance to include MaintenanceMaintenance Schedule To Fill the Water HeaterPerformance data Fixture Count Guide How to properly Size Your Indirect Water HeaterEstimate your peak hour demand as follows 110First Hour Rating 180F Boiler Loop Water Knight Boiler First Hour Rating 180F Boiler Loop Water Universal Sizing First Hour Rating 200F Boiler Loop Water Universal Sizing

SIT030, SIT119 specifications

Lochinvar is a renowned manufacturer of high-efficiency heating solutions, including a range of commercial and residential boilers. Among their offerings are the Lochinvar SIT119 and SIT030 models, which exemplify the brand's commitment to innovation and efficiency in modern heating systems.

The Lochinvar SIT119 is designed for medium to large residential applications, boasting a powerful heating capacity. This model features a robust stainless steel heat exchanger that not only enhances durability but also promotes optimal heat transfer. As part of Lochinvar’s commitment to energy efficiency, the SIT119 incorporates advanced features such as a modulating burner system that adjusts the flame output based on the heating demand, resulting in lower energy consumption and reduced operational costs.

In addition to its efficiency, the SIT119 is equipped with user-friendly controls that allow homeowners and technicians to easily manage and monitor the system. Its intuitive digital display provides real-time information on system performance and diagnostic capabilities, facilitating maintenance and troubleshooting. Furthermore, the SIT119’s compact design enables versatile installation options, making it suitable for various residential spaces.

On the other hand, the Lochinvar SIT030 is tailored for smaller residential applications. Despite its smaller size, it doesn’t compromise on performance or efficiency. This model also features a high-quality stainless steel heat exchanger, ensuring longevity and consistent heating performance. Like the SIT119, the SIT030 utilizes a modulating burner system to optimize energy use, making it an environmentally friendly choice for homeowners seeking effective heating solutions.

One notable characteristic of the SIT030 is its low NOx emission design, which aligns with contemporary environmental standards and helps reduce the carbon footprint associated with heating. Additionally, both models support easy integration with existing heating systems and can be paired with renewable energy sources, such as solar thermal systems, maximizing their efficiency and sustainability.

In summary, the Lochinvar SIT119 and SIT030 models stand out in the heating market, combining advanced technologies with high efficiency and user-friendly features. Their stainless steel construction, modulating burners, compact design, and emissions compliance make them excellent choices for homeowners looking to invest in reliable and eco-conscious heating solutions. With these models, Lochinvar continues to lead in producing innovative products that meet the evolving demands of the heating industry.