LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lit with a piezo igniter. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Ensure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page. 6. Wait five (5) minutes to clear out any gas. If you then smell gas,

2. Access the lower control compartment.

STOP! Follow “B” in the safety information above on this page. If you

do not smell gas, go to the next step.

3.Turn OFF/ON switch to “OFF” (and remote wall switch, if appli- 7. Push in gas control knob slightly and turn counterclockwise

cable).

to “PILOT.”

4.Verify main line shut-off valve is open.

5.Push in gas control knob slightly and turn clockwise to “OFF.”

SIT Millivolt Gas Valve

 

 

 

 

OUT

IN

TP/TH

TPTH

 

 

 

 

TP

TP

 

IH

 

 

 

 

OF F

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

I

 

TH

 

L OW

it

L

TH

 

O

 

 

 

NO

T

 

 

 

 

 

 

 

P

 

 

 

 

I

 

 

 

 

TOL

 

 

 

 

 

 

 

- LO / HI +

GAS CONTROL

 

 

 

 

KNOB

 

BURNER

 

 

PIEZO

 

 

OFF/ON SWITCH

 

 

IGNITER

 

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 1/2 minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If pilot will not stay lit after several tries,

 

 

turn the control knob to “OFF” and call

Millivolt Pilot

 

your service technician or gas supplier.

 

 

9.Turn gas control knob counterclockwise to “ON.”

10.Close lower control compartment.

18

 

 

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for

4.

Depress gas control knob slightly and turn clockwise

 

normal service.

 

to “OFF.” Do not force.

2.

For complete shutdown, turn remote wall switch to “OFF.”

5.

Close lower control compartment.

3.Access the lower control compartment.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 18
Contents 875,024M REV. NC 04/2005 MPB35ST-NMMPB35ST-NE MPB35ST-PMListing Agency OTL Report No -F-27-5 Congratulations Orifice Sizes Sea Level to High Altitude All Models Safety & Warniing InformationBurn-in Period Burner Orifice Sizes all models Elevation Natural PropaneSIT Millivolt Operation and Care of Your ApplianceMillivolt Appliances Valve see FigureSpill Switch Operation Vent Operation TestEnsure Appliance is OFF Pilot only and Cool Maintenance Outside Combustion Air ControlsGlass Front See Figure LOG SET Top View of Logs Top View of Logs InstalledCA B ReferenceRemove front glass enclosure panel from appliance Placement of Glowing EmbersRead LOG Warnings on page 9 Before Proceeding Position The Groove in The Back of Log CThis appliance is not designed to burn wood. Any attempt to Burner Adjustments Qualified Technicians onlyAir Shutter Adjustment Guidelines Flame Appearance & SootingMaintenance Task Accomplishing Person Procedure While HOTSwitch or remote control TroubleshootingSymptom Possible Causes Corrective Action Operation, the standard burnerTroubleshooting Procedure Electronic Ignition System Wiring Diagrams WarrantyReplacement Parts Lennox Hearth ProductsAccessory Components Screen Heat Guard Kit Clean Face Panel KitsBrickaded Panel Liner Kit Door Frame KitsPiece Polished Brass and Brushed Stainless Louvers Kits Arch Door KitsPolished Brass and Brushed Stainless Hood Kits Outside Air Kits Models FOAK-4 and FOAK-4LDTo Turn OFF GAS to Appliance Normal service To OFF. Do not forceLighting Instructions What to do if YOU Smell GASClose lower control compartment door SwitchWhat to do if YOU Smell GAS To Shut OFFReplacement Parts MPB35ST 20 P/N 875,024M REV. NC 04/2005West Taft Avenue Orange, CA

MPB35ST-NM specifications

Lennox International Inc., a leader in the heating, ventilation, and air conditioning (HVAC) industry, offers the MPB35ST-NM model as part of its comprehensive range of integrated solutions. This finely engineered unit is designed to provide exceptional performance and energy efficiency while ensuring optimum home comfort.

One of the standout features of the Lennox MPB35ST-NM is its modular design, which allows for flexible installation and easy integration with existing systems. This unit is particularly beneficial for residential settings where space may be at a premium. It also supports efficient zoning, enabling tailored climate control for different areas of the home.

The MPB35ST-NM utilizes advanced multi-stage heating technology, which means it can adjust its output to match the specific demands of the environment. This significantly enhances energy efficiency and reduces operational costs. The unit operates with a high Seasonal Energy Efficiency Ratio (SEER) rating, ensuring optimal performance without excessive energy consumption.

Additionally, the MPB35ST-NM is equipped with smart technology features that allow homeowners to monitor and manage their heating system remotely. Through a user-friendly app, users can adjust settings, schedule maintenance reminders, and receive performance alerts, all of which contribute to an improved user experience.

Another key characteristic of the MPB35ST-NM is its quiet operation. The unit is designed with sound-dampening components that minimize noise during operation, ensuring that homeowners can enjoy a peaceful living environment.

Durability is another hallmark of Lennox products, and the MPB35ST-NM is no exception. Constructed with high-quality materials, this unit is built to withstand the rigors of daily use while offering long-lasting reliability. Additionally, Lennox provides robust customer support and warranty options, giving customers peace of mind in their investment.

In summary, the Lennox International Inc. MPB35ST-NM model stands out as a leader in home heating solutions. With its adaptable design, energy-efficient technology, smart features, quiet operation, and dependable durability, it meets the evolving needs of modern households, making it an excellent choice for those seeking comfort and efficiency in their heating systems.