Raypak H-0066B, H-0042B, H-0030B, H-0090B Soot Corrosion Disengaged, System Shut Down Procedure

Page 4

1. Burner Inspection.

Clean the main burners and air louvers of dust, lint and debris. With burner in operation, make a visual check of the burner flame and the pilot flame (when equipped). Yellow flames indicate some restriction of combustion air openings. A bright orange, luminous flame is not normal and can cause sooting under prolonged operation. Should this condition be ob- served, contact immediately a qualified service agency to correct the problem.

2. Venting System Inspection.

Visually inspect the venting system. Make sure the vent connections are secure and have not become disengaged. Look for any indication of corrosion, or carbon (soot) streaks which could cause leakage of products of combustion into the living space. Inspect the vent terminal outside the building. Make sure it is not damaged to cause blockage or restriction of the flue gas. Observe for any indication of soot. The presence of soot accumulation in the vent terminal would indicate an abnormal operating condition. This should be investigated and corrected by a qualified service agency.

SOOT

CORROSION

DISENGAGED

3. Circulator (Water Pump) Inspection.

The circulator is permanently lubricated and thus, will not require any lubrication. Inspect for evidence of water leakage. This should be corrected to prevent any possible damage to electrical components of the boiler.

CAUTION: In case of a prolonged power failure during freezing weather conditions, boiler and piping system must be drained completely to avoid possible damage to the heating system.

To prevent the potential freezing damage to the heating system, it is recommended that the following system shut down procedure be performed.

SYSTEM SHUT DOWN PROCEDURE

1. Set the room thermostat to "OFF" or the lowest setting.

2. Turn off all electric switches to the boiler.

3. Turn off all gas valves supplying gas to the boiler. Refer to operating instruction label on the boiler.

4. Shut off the water supply to the boiler piping system loop.

5. Open drain valve on the boiler to remove water from the boiler and the piping circuits.

NOTE: It may be necessary to open the purge valves and/or manual air vents to facilitate complete drainage of water from the heating system.

4. Service Assistance.

If service is required on the boiler, contact your local service agency or Raypak, Inc. can refer you to the proper qualified service agency. It is important and very often will save time if you state the model number, serial number and type of gas used. This information will be found on the nameplate of the boiler.

Fig.#8204.0

Raypak, Inc., 31111 Agoura Road, Westlake Village, CA 91361-4699 (818) 889-1500 FAX (818) 889-4522

Litho in U.S.A.

www.raypak.com

4

Image 4
Contents What to do if YOU Smell GAS Lighting Instructions for Standing Pilot ModelsBlocked Vent SHUT-OFF System What to do if YOU Smell GASSET Lighting Instructions for Automatic Ignition ModelsTo Turn OFF GAS to the Boiler Inspection and Maintenance Procedures To Turn OFF GAS to BoilerHoneywell Pilot Blue FlameSystem Shut Down Procedure Soot Corrosion Disengaged

H-0135B, H-0066B, H-0180B, H-0090B, H-0030B specifications

Raypak is a renowned name in the heating and cooling industry, particularly recognized for its innovative residential and commercial pool heaters. Among its diverse lineup, the H-series models, including the H-0030B, H-0180B, H-0066B, H-0135B, and H-0042B, stand out for their advanced features, robust performance, and user-friendly design.

The H-0030B is an entry-level model designed for smaller pools and residential applications. It boasts a compact design and is remarkably energy-efficient, featuring a copper heat exchanger that enhances heat transfer while minimizing energy consumption. Its straightforward controls allow for easy operation, making it a top choice for homeowners seeking a reliable heating solution.

The H-0180B offers a step up in performance and capacity, perfect for medium to larger pools. This model is equipped with a unique digital thermostat that provides precise temperature control, ensuring water warmth without unnecessary energy expenditure. It also integrates advanced safety features, including a pressure switch to prevent operation when the water flow is insufficient.

The H-0066B model strikes a balance between efficiency and power. It utilizes a powerful fan-forced convection system, allowing for rapid heating. This model is particularly appreciated for its low NOx emissions, meeting stringent environmental regulations while providing robust heating capabilities.

The H-0135B contributes notable power, ideal for larger commercial pools or high-demand residential setups. Its advanced control system enables users to set and maintain desired temperatures with ease. Moreover, the H-0135B is designed for longevity, incorporating durable materials to withstand various weather conditions.

Finally, the H-0042B caters to those in search of a high-capacity heater. With an enhanced thermal efficiency rating, this model guarantees lower operational costs and faster heating times. It features an easy-to-read LCD display, allowing users to monitor and adjust settings effortlessly.

In summary, the Raypak H-series models combine modern technology and user-friendly features, ensuring efficient heating for pools of all sizes. Their commitment to energy efficiency, safety, and durability makes them a top choice for both residential and commercial applications. Whether you're a homeowner looking to extend your swimming season or a business needing reliable heating, these models provide excellent performance tailored to your specific needs.