Maytag HE2966T, HE3940T, HE3940L, HE3950T, HE3940S, HE3966T, HE3950S manual Troubleshooting contd, Reset

Page 26

Troubleshooting (cont'd)

1. Before beginning, turn "OFF" electrical power supply to

NOT ENOUGH OR NO HOT WATER

the water heater.

 

_"

a_ WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF". Failure to do this could result in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE.

2.Remove the two screws securing the access panel and remove panel.

3.Remove the insulation block to expose the opening.

4. Reset the high limit by pushing in the red button marked

"RESET".

1. In a new installation, the water heater may not be proper- ly connected. Make sure the cold water supply valve is open. Review and check piping installation. Make sure that the cold water line is connected to the cold water inlet to the water heater and the hot water line to the hot water outlet on the water heater.

2.Make sure the electrical supply to your water heater is "ON".

3. Check for loose or blown fuses in your water heater cir- cuit. Circuit breakers weaken with age and may not han- dle their rated load and should be replaced.

4. Make certain the disconnectswitch, if used, is in the "ON" position.

5.Check to see the electric service to your house has not been interrupted. If this is the case, contact the electric company.

6.Axe the thermostats set to the desired temperature? See "Temperature Regulation" section.

7. If you had experienced very hot water and now no hot water, the problem may be due to the high temperature shut off system. See "High Temperature Shut Off System" in the "Troubleshooting" section.

8. During very cold weather, the incoming water wi]l also be colder and it will require a longer time to become heated.

5. Replace the insulation block so that it completely covers the thermostat and element.

6. Replace the access panel.

7. Turn "ON" electric power to the water heater.

_CAUTIONI

If the high limit must be reset again, call Maytag

Customer Service at

1-800-788-8899

for an

autho-

rized servicer to find

out why the high limit

turned I

"OFF" the electric power.

 

I

9.The hot water usage may exceed the capacity of the water heater. If so, wait for water heater to recover after abnor-

mal demand. Also examine pipes and faucets for possible water leaks.

10. If you can not determine the problem, then call the Maytag Service Department.

WATER IS TOO HOT

Adjust the thermostat to a lower setting. See the

"Temperature Regulation" section.

26

Image 26
Contents LVLYIAG DEATH, Serious Bodily INJURY, or Property Damage AwarningSafety Instructions contd Table of Contents Attempting to Install or Operate the Water Heater Customer InformationProduct Specifications 173I 90F swer17 3IAccessories and Tools Needed Instructions for Installation Removing the Old Water HeaterLocating The New Water OUS BOD LY NJURY, or Property Damage Instructions for Installation contdConvertible Lower Element Water Piping Irgap V4ARNING Relief Valve Opening Instructions for Installation contdHotold Conduit CouplingDEATH, Serious Bodily Injury or Property Damage Filling the Water HeaterNever use this water&CAUTIONheater unless it is completely Pa50Converting the Lower Element contd Result in DEATH, Serious Bodily INJURY, or Property DamageOUS BOD LY NJURY,OR Propertydamage Elem ENT Wiring Water Heaters Equipped for ONE VoltageAirgap Conduit Temperature Pressure ReliefvalveDo not capor plug Floordrain=mver.o=urec .+ Service and MaintenanceUpper Thermostat Adjustable Behind Upper Access Panel Is turned OFF. Failure to do this could result Upper Thermostat TEMPERATURE-PRESSURE ReliefvalveDischargepipe Lower ThermostatDEATH, Serious Bodily INJURY, or Property Service and Maintenance contdHazard of Electrical SHOCK! Before removing Service and Maintenance contd Water HeaterElement Cleaning Replacement contdIs turned UOFFR. Failure to do this could result CapassemblyDrain HandleandAIR in HOT Water Faucets TroubleshootingSmelly Water High Temperature Shut OFF System Rumbling NoiseTroubleshooting contd ResetLY INJURY, or Property Damage Leakage CheckpointsChecking Repair Parts List See N OTE on Repair Parts List contdDescripti on Part Numbers MAYrAG Electricwater Heaters Model Numbers HE2940L40 Gallon HE3940L40 GallonSee Note on PA GE Model Numbers HE2940L40 Gallon HE3940L40 Gallon KEY PartDescription Part Numbers See Note onWa tts, order p art numb 6600 110 7 r lacemen t Gallon Model Numbers KEY Part GallonGallon HE29SOT Repair Parts List contd MAYTAG/STATE Partnumber Conversionkey MaytagstatePage Warranty 660 0109