Raypak RHP 33 installation manual Unit is not Running

Page 11

operation. After the desired temperature is reached, return the system to normal operation.

Is airflow through the unit being obstructed? Restrictions such as shrubbery, tall grass, dirty coils, or any other obstruction to airflow will reduce performance.

Is the pool blanket/cover being used? Unblanketed pools can lose up to 6° per night compared to 2 degrees or less when a blanket is used. Without a blanket, the total heat gained during the day can be lost overnight.

Are rapid heat losses occurring in some other way, such as high wind, waterfalls, spa spillage, bubblers, rainfall, flow through solar panels at nights, or a high water table?

Is water flow through the unit adequate? Check the system for obstructions, such as a clogged filter pump strainer or a dirty filter.

B.UNIT IS NOT RUNNING

Is the control panel Power lamp ON? If not, the power switch may be shut OFF or circuit breaker tripped. Reset the power by switching it OFF, then back ON.

Verify that the circuit breaker is set and operating properly before calling for service.

Is the thermostat setting correct? Verify that the temperature has been properly set on the thermostat, and that it is higher than the current water temperature.

Have you waited 6 minutes for the time delay? After the unit has been running and then shut OFF for any reason, there is a 6-minutes timed cycle before operation can begin again.

Is the Water Flow lamp OFF? This lamp will turn OFF if not enough water is flowing through the heater. Improperly positioned valves or a dirty filter could decrease the flow of water required for efficient operation. When the Water Flow lamp is ON, proper flow is present. If this lamp is OFF, but you can feel normal flow at the pool returns, check the water valves or settings.

Is the Defrost Active lamp OFF? If this lamp is ON, the fan will be running but not the compressor. The unit is waiting for the frost to melt or the air temperature to rise before heating is resumed.

Is the Heat Demand lamp ON? If not, then the thermostat setting is not higher than the temperature of the pool water. Raise the thermostat setting.

Is the Low Pressure lamp ON? If this lamp is ON, there is a problem with the unit that will require service. Turn the unit OFF and call the number shown in the CONTACT INFORMATION at the beginning of this manual.

SERVICE CALL REQUESTS

Determine if the problem is:

Warranty Service (within 5 years of installation)

Non Warranty Service (beyond 5 years of installation)

Maintenance-related (power supply, water flow, or pool system time clock adjustment)

NOTE: The MANUFACTURER IS NOT RESPONSIBLE for maintenance adjustments.

8

Image 11
Contents Owner Product Safety Signs and Labels Owner and Installation Manual Introduction InstallationII. Electrical Connections Typical System Electrical Power RequirementsIII. Water Connections IV. Controls and Indicator LampsInitial Start-Up and Check VII. Heat Pump Running Time VI. Seasonal Start-Up or Annual CheckIX. Freeze Protection MaintenanceVIII. Summer Shutdown Unit is RUNNING, but not Heating XI. TroubleshootingUnit is not Running Power Supply Water Plumbing DiagramsTB1 Heat Pump Schematic112 Control Panel Assembly Replacement Parts ListFront Back Control Panel Cover Assembly Replacement Parts ListItem QTY Description Heat Pump Assembly Replacement Parts List RHP

RHP 33 specifications

The Raypak RHP 33 is a high-performance heater designed to meet the needs of both residential and commercial swimming pools and spas. Known for its reliability and energy efficiency, this unit stands out in the market for several reasons.

One of the main features of the RHP 33 is its high-efficiency design. With an output of 333,000 BTUs, it offers rapid heating capabilities, ensuring that your pool or spa reaches the desired temperature quickly, even in cooler climates. The heater is powered by natural gas or propane, giving users flexibility depending on their fuel preferences.

The Raypak RHP 33 incorporates innovative technology that enhances its durability and performance. One notable feature is its durable titanium heat exchanger, which is known for resisting corrosion and ensuring longevity. This is particularly important for those using saltwater pools, as conventional heaters may degrade more quickly in such environments.

The unit also features a built-in digital thermostat that allows for precise temperature control. Users can easily adjust the temperature settings via a user-friendly interface, making it simple to maintain the perfect warmth for leisure activities. The RHP 33 is equipped with an electronic ignition system that provides reliable starts, eliminating the hassle of pilot lights and enhancing safety.

In terms of installation, the Raypak RHP 33 is designed for outdoor use, with a robust housing that protects against the elements. Its compact size allows for versatility in placement without sacrificing performance. Furthermore, the heater’s low NOx emissions technology ensures compliance with environmental regulations, making it an eco-friendly choice for homeowners who are conscious about their ecological footprint.

The RHP 33 also boasts a self-diagnostic system, which provides real-time feedback on its performance and alerts users to potential issues, thereby minimizing downtime. This feature is coupled with easy access to internal components, ensuring straightforward maintenance and repairs when necessary.

In summary, the Raypak RHP 33 is a cutting-edge pool and spa heater that delivers efficiency, reliability, and user-friendly features. With its advanced technologies, including a titanium heat exchanger, digital controls, and environmental compliance, it is an excellent choice for anyone looking to enjoy their water features year-round.