4 - Use in Standard Mode

Starting operation

Press the power button when the unit has received the signal it gives out two 'beep' tones. The operation light switches on and the heat pump water heater starts operation. The compressor will restart after 3 minutes to protect the system if the interval is shorter than 3 minutes from the last shut down to the present switch on.

Mode Selection

Press the 'M' button to chose the mode of heating and cooling (this key is invalid for the single water chiller or single water heater)

Temperature Setting Selection

1)Press "Temperature Adjustment Button to set the temperature 1 degree higher

2)Press "Temperature Adjustment Button to set the temperature 1 degree higher

3)Temperature range is set in heating mode: 45°C to + 55°C (Single water chiller is without this function)

4)Temperature range is set in cooling mode: 10°C to + 35°C (Single water heater is without this function)

Timer Switch On

1)When the heater is off press the timer-on button to set time for the timer-on switch. Press the button once to change the time interval of 1 hour in a cyclic manner of 1,2,...24,1,2 (The display shows the previous time as the starting time of the present setting)

2)When it reaches the switch-on time, the heat pump water heater will operate in the preset time mode.

3)Press the timer-on button again, and the set up is cancelled.

4)If the on/off button is pressed while the unit is under the timer on setting, the unit will start immediately. The timer setting is at that point cancelled.

Timer-Off Switch

1)When the heater is on, press thetimer-on button to set time for the timer-on switch. Press the button once to change the time interval of 1 hour in a cyclic manner of 1,2,...24,1,2 (The display shows the previous time as the starting time of the present setting)

Premier Heat Pumps – Water Heater and Chiller Manual

Page 14

Image 14
Contents Premier Heat Pumps Premier Heat Pumps Water Heater and Chiller Manual Content InstallationPremier Heat Pumps Water Heater and Chiller Manual Premier Heat Pumps Water Heater and Chiller Manual Description of the Heat Pump OutsideInside Dimensional and Technical Characteristics PHP HWC-150 PHP HWC-200 PHP HWC-260Installation Locating the UnitWater connections Connections General Power Supply CharacteristicsElectrical Connections Electrical ProtectionHow the reversible heat pump operates How the pump operates in heating modeOperating cooling mode or defrosting mode Display and Control Screen Description Use in Standard Mode Coercive Defrosting Defrost operation Instructions for the InstallerUnit controller and parameters Parameters for Exiting Defrost Mode Maintenance InstructionsFault Codes and Fault Descriptions Recommendation Contact the installer or service agentGas Flow Diagram Premier Heat Pumps Water Heater and Chiller Manual Wiring Diagram Problems and Solutions Problem Observation Probable Cause

PHP HWC-150, PHP HWC-200, PHP HWC-260 specifications

The Premier PHP HWC-150, PHP HWC-260, and PHP HWC-200 are cutting-edge water heaters designed to meet the growing demand for energy-efficient and reliable heating solutions in residential and commercial applications. These models exemplify the perfect blend of advanced technology, user-friendly features, and robust performance, making them an excellent choice for customers seeking both value and efficiency.

The PHP HWC-150 has a compact design, making it ideal for small spaces. It offers a powerful heating capacity that ensures a consistent supply of hot water for everyday needs. This model is equipped with a high-efficiency heating element and advanced temperature control, allowing users to set their desired temperature with precision. Additionally, it features a digital display that provides real-time information on water temperature and operational status.

The PHP HWC-260 is a step up in performance, catering to larger households or light commercial applications. It boasts a larger tank capacity, ensuring ample hot water even during peak demand. The unit incorporates innovative insulation technology to minimize heat loss, enhancing energy efficiency. The PHP HWC-260 also includes a smart technology feature that adjusts heating cycles based on user patterns, optimizing energy usage and reducing costs.

The PHP HWC-200 bridges the gap between the HWC-150 and HWC-260, offering versatility for medium-sized households. It combines the best features of both models while maintaining a compact footprint. The HWC-200 is designed for quick recovery and efficient heating, making it suitable for various applications. Its user-friendly interface and customizable settings empower users to manage their hot water supply effectively.

All three models are constructed from durable materials, ensuring long-lasting performance and reliability. They include safety features such as automatic shut-off and thermostatic controls, providing peace of mind for users. Furthermore, these water heaters are designed with sustainability in mind, incorporating eco-friendly refrigerants and components that comply with environmental regulations.

In conclusion, the Premier PHP HWC series, including the HWC-150, HWC-260, and HWC-200, signifies a leap forward in water heating technology. Their advanced features, energy efficiency, and reliability make them suitable choices for a range of settings, reflecting the commitment to quality and innovation that Premier is known for. Whether for a small home or a larger facility, there is a model that fits every hot water need.