Premier PHP HWC-150, PHP HWC-260, PHP HWC-200 Premier Heat Pumps Water Heater and Chiller Manual

Page 5

! Caution !

Do not climb on the unit or try to move

Keep out of reach of children. Do not

it once installed.

allow them to play on or near the unit.

 

 

Do not place foreign objects or fingers

Important: Ensure that the plug remains

into the air inlet/outlet. The fan runs at

clean, free from moisture, foreign objects

high speed and can cause serious

and dirt. Ensure that the plug is properly

injury. Do not operate the unit without

inserted or hard wired by a qualified

the safety grill in place.

electrician.

 

 

If the unit operates abnormally, stop

 

the unit by firstly switching it off and

Do not clean the appliance with water.

then unplug the unit. For example, if

Water will go into the unit and will destroy

there is a strange smell or abnormal

the insulation.

noise coming from the unit.

 

 

 

Turn the unit off at the wall before

Do not pull on the cable to unplug the

unplugging the unit. Do not disconnect

unit, damage to the plug and cable could

the power while the unit is running.

occur

 

 

 

Ensure that the power to the heat pump is

Do not touch the plug with wet hands,

disconnected before removing leaves,

as electric shock can occur.

particles or other foreign objects from the

 

air inlet vanes.

 

 

Verify the network specifications, with the unit data recorded on the heat pump prior to installation.

Any additional disinfectant systems, such as chemical or electrolysis are not recommended for use with this hot water heat pump. The pump MUST be installed prior to these systems.

For optimal operation of the heat pump, the following maximum values apply: A. Use of free chlorine : max : 2.6mg/l

B. Total bromine : max : 5.6mg/l

C. pH : between 6.5 and 8.0

Premier Heat Pumps – Water Heater and Chiller Manual

Page 5

Image 5
Contents Premier Heat Pumps Premier Heat Pumps Water Heater and Chiller Manual Installation ContentPremier Heat Pumps Water Heater and Chiller Manual Premier Heat Pumps Water Heater and Chiller Manual Outside Description of the Heat PumpInside PHP HWC-150 PHP HWC-200 PHP HWC-260 Dimensional and Technical CharacteristicsLocating the Unit InstallationWater connections Electrical Connections General Power Supply CharacteristicsConnections Electrical ProtectionHow the reversible heat pump operates How the pump operates in heating modeOperating cooling mode or defrosting mode Display and Control Screen Description Use in Standard Mode Coercive Defrosting Defrost operation Instructions for the InstallerUnit controller and parameters Fault Codes and Fault Descriptions Maintenance InstructionsParameters for Exiting Defrost Mode Recommendation Contact the installer or service agentGas Flow Diagram Premier Heat Pumps Water Heater and Chiller Manual Wiring Diagram Problem Observation Probable Cause Problems and Solutions

PHP HWC-150, PHP HWC-200, PHP HWC-260 specifications

The Premier PHP HWC-150, PHP HWC-260, and PHP HWC-200 are cutting-edge water heaters designed to meet the growing demand for energy-efficient and reliable heating solutions in residential and commercial applications. These models exemplify the perfect blend of advanced technology, user-friendly features, and robust performance, making them an excellent choice for customers seeking both value and efficiency.

The PHP HWC-150 has a compact design, making it ideal for small spaces. It offers a powerful heating capacity that ensures a consistent supply of hot water for everyday needs. This model is equipped with a high-efficiency heating element and advanced temperature control, allowing users to set their desired temperature with precision. Additionally, it features a digital display that provides real-time information on water temperature and operational status.

The PHP HWC-260 is a step up in performance, catering to larger households or light commercial applications. It boasts a larger tank capacity, ensuring ample hot water even during peak demand. The unit incorporates innovative insulation technology to minimize heat loss, enhancing energy efficiency. The PHP HWC-260 also includes a smart technology feature that adjusts heating cycles based on user patterns, optimizing energy usage and reducing costs.

The PHP HWC-200 bridges the gap between the HWC-150 and HWC-260, offering versatility for medium-sized households. It combines the best features of both models while maintaining a compact footprint. The HWC-200 is designed for quick recovery and efficient heating, making it suitable for various applications. Its user-friendly interface and customizable settings empower users to manage their hot water supply effectively.

All three models are constructed from durable materials, ensuring long-lasting performance and reliability. They include safety features such as automatic shut-off and thermostatic controls, providing peace of mind for users. Furthermore, these water heaters are designed with sustainability in mind, incorporating eco-friendly refrigerants and components that comply with environmental regulations.

In conclusion, the Premier PHP HWC series, including the HWC-150, HWC-260, and HWC-200, signifies a leap forward in water heating technology. Their advanced features, energy efficiency, and reliability make them suitable choices for a range of settings, reflecting the commitment to quality and innovation that Premier is known for. Whether for a small home or a larger facility, there is a model that fits every hot water need.