Pentair EQ SERIES Section Troubleshooting, Problems and Corrective Actions

Page 22
Section 7

16

Section 7

Troubleshooting

Use the following troubleshooting information to resolve possible problems with your EQ Series pump.

Note: Turn off power to unit prior to attempting service or repair. WARNING — RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.

Improperly installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.

1.If you are not familiar with your pool filtering system and/or heater:

a.Do NOT attempt to adjust or service without consulting your dealer, or a qualified pool technician.

b.Read the entire Installation & User’s Guide before attempting to use, service or adjust the pool filtering system or heater.

Note: Turn off power to unit prior to attempting service or repair.

Problems and Corrective Actions

Problem

CorrectiveAction

 

 

Pump Will Not Prime

No water in Strainer Pot

 

Lid is not tight

 

Damaged lid O-Ring

 

Water level below Skimmer

 

Strainer or Skimmer Basket clogged

 

Closed Valve in Piping System

 

Air leak in Suction Line

 

Pump installed more than 10 ft. above Water Level or otherwise

 

too high for Hydraulic Conditions of Pool Plumbing System

 

Pump Shaft rotating in wrong direction

 

 

Low Flow- High Filter Pressure

Filter is dirty

 

Restriction in Filter Line

Low Flow- Low Filter Pressure

Strainer or Skimmer Basket clogged

 

Clogged Impeller

 

Air leak in Suction Line

 

Restriction in Suction Line

 

Cavitation - NPSHA less than NPSHR

 

Pump Shaft rotating in wrong direction

 

 

Motor Does Not Turn

Power Switch is off

 

Circuit Breaker has tripped

 

Thermal Protector has tripped

 

Pump is in OFF mode of Timer

 

Motor Shaft is locked by bad Bearing

 

Impeller is jammed

 

 

Motor Over Heating

Electrical Supply Connections are incorrect

 

Wiring to Pump is undersized

 

Inadequate Voltage supplied to Site

 

Ventilation is inadequate for Motor

 

Voltage differential between legs of 3 Phase Circuit >5%

 

Pump Shaft rotating in wrong direction

 

 

High Pitch OR Growling Noise

Air Leak in Suction Line

coming from WET END of Pump

Cavitation - NPSHA less than NPSHR

 

A Valve, Elbow or Tee is located too close to the Suction Inlet of the Pump

 

Pump Shaft rotating in wrong direction

 

 

 

 

EQ Series Pump Installation and User’s Guide

Image 22
Contents IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS High Performance Commercial PumpInstallation and Users Guide EQ SERIESCustomer Service Web siteTable of Contents EQ Series Pump Installation and User’s GuideConsumer Information and Safety IMPORTANT SAFETY PRECAUTIONSImportant Notice IMPORTANT SAFETY PRECAUTIONS continued General Installation Information Section Introduction EQ Series High Performance Commercial Pump OverviewGeneral Features Additional FeaturesInstalling the EQ Series Pump Section InstallationMechanical Installation and Pressure Testing Mechanical Installation, cont.’d Pressure Testing Pressure Testing, cont’d This section describes how to secure and wire the EQ pump Electrical Requirements and Field WiringSection Electrical Requirements Electrical Requirements and Field Wiring, cont’d This section describes how to prime the EQ pump Section Initial Operation of PumpEQ Series Pump Installation and User’s Guide Section Maintenance Cleaning of the Strainer BasketPreventative Maintenance Section Servicing Disassembly Assembly Note Turn off power to unit prior to attempting service or repair Section TroubleshootingProblems and Corrective Actions Section Replacement Parts Illustrated PartsPENTAIR POOL PRODUCTS, INC 50HZ PUMP PERFORMANCE CURVES EQ SERIES Section Pump Technical DataPENTAIR POOL PRODUCTS, INC 60HZ PUMP PERFORMANCE CURVES EQ SERIES WATEREngineering Specifications SAVE THESE INSTRUCTIONSDimensional Data ALL DIMENSIONS ARE IN INCHESPage P/N 350061 Rev. E 1/24/06