Multiquip QP40TH Water, Re-prime later, Port, Hose on the inlet side of the pump, Information

Page 13

QP40TH — PUMP COMPONENTS

Figure 2 shows a typical application using the QP40TH Centrifugal Trash pump. Please note that this pump is intended for the removal of clean water and water containing some debris and solids. Maximum size of solids should not exceed 2 inches (50 mm) in diameter. DO NOT set strainer on bottom of water bed. Placing the strainer above the water bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.

Figure 2. QP-40TH Pump Application

1.

Pump – The model MQ40TDH is 4-inch trash pump used

 

in general de-watering applications. Typical dewatering

 

applications consist of manholes, septic tanks, fast and

 

slow seepage ditch water, silt water, mud water and muck

 

water.

2.

Fill Cap – Prior to operation, the pump casing should be

 

filled with water.Remove this cap to add water to the pump.

 

After the initial prime, a sufficient amount of water will be

 

retained in the casing so that the operator will not need to

 

re-prime later.

 

If the casing is dry or has insufficient water, the pump will

 

have difficulty in priming which could lead to premature

 

mechanical seal wear thus causing damage to the pump.

3.

Discharge Port – Connect a 4-inch discharge hose to this

 

port.

4.

Worm Clamp – Used to secure the hose to the inlet and

 

outlet ports on the pump. Use two clamps to secure the

 

hose on the inlet side of the pump.

5.

Discharge Hose – Connect this flexible rubber hose to

 

the discharge port on the pump. Make sure that the hose

 

lays flat and is not kinked. Use only recommended type

discharge hose. Contact Multiquip parts department for ordering information.

6.

Suction Port – Connect a 4-inch inlet hose to this port.

 

Use two worm clamps to secure the hose.

7.

Suction Hose – Connect this flexible rubber hose to the

 

suction port on the pump. Make sure that the hose lays flat

 

and is not kinked. Use only recommended type suction

 

hose. Contact Multiquip parts department for ordering

 

information

8.

Clean-out Cover Handles – To gain access to the pump's

 

clean-out area, grip both handles, then pull to remove cover.

 

Make sure both locking knobs have been released before

 

attempting to remove clean-out cover.

9.

Drain Plug – Remove this plug to drain water from the

 

pump.

10. Clean-out Cover – Remove cover to gain access to the clean-out area.

11. Locking Knobs– Turn both knobs clockwise to secure clean-out cover, turn counter-clockwise to release cover.

12. Strainer – Always attach a strainer to bottom side of the suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water.Running the pump with the strainer above water for long periods can damage pump.

QP40TH — PARTS & OPERATION MANUAL — REV. #1 (10/01/02) — PAGE 13

Image 13
Contents GAS Powered Trash Pump Model QP40TH Honda Page Heres HOW to GET Help Table of Contents UPS Third Day Service at one-half of actual freight cost Parts Ordering ProceduresSeriously injured if you do not follow directions QP40TH Safety Message Alert SymbolsInstructions Always wear approved respiratory protectionRules for Safe Operation General SafetyRules for Safe Operation Suction & Discharge Size Specifications PumpSpecifications Engine QP40TH General Information Water Attempting to remove clean-out coverRe-prime later PortQP40TH Basic Engine Clean the pump, removing dirt Dust, particularly the engine Read safety instructions at Beginning of manualCleaner Enclosed area structure thatRead safety instructions at the beginning of manual QP40TH PRE-SETUP PumpPlace the engine fuel valve lever to the on position Place the engine ON/OFF switch in the on positionPlace the fuel shut-off lever in the OFF position QP40TH Initial START-UP EnginePage Pump Vacuum Test QP40TH Maintenance PumpQP40TH Maintenance Pump Engine Maintenance Schedule QP40TH Maintenance EngineQP40TH Maintenance Engine Pump Storage QP40TH Preparation for Long -TERM StoragePage QP40TH Troubleshooting Engine QP40TH Troubleshooting ENGINE/PUMP Explanation of Code in Remarks Column To 5 Units QP40TH Suggested Spare PartsPump Assy QP40TH Pump AssyCasing ENGINE, Honda GX340K1QA2Casing Cover Delivery Cover NPT4QP40TH Pump Assy Pump M10 NUT DELIVERY/SUCTION Cover M12Spring Washer M12 Spring Washer M10AIR Cleaner Assy Honda GX340K1QA2 AIR Cleaner AssyCOVER, AIR Cleaner ELEMENT, AIR CleanerGROMMET, AIR Cleaner COLLAR, AIR CleanerCamshaft Assy Honda GX340K1QA2 Camshaft AssyROD, Push SPRING, Weight ReturnARM, Valve Rocker LIFTER, ValvePiston Assy Honda GX340K1QA2 Piston AssyRing SET, PISTON- Standard BOLT, Connecting RODRing SET, PISTON- OS Ring SET, PpistonCrankcase Cover Assy Honda GX340K1QA2 Crankcase Cover AssyHOLDER, Governor Weight WEIGHT, GovernorPIN, Governor Weight GASKET, Case CoverCrankshaft Assy Honda GX340K1QA2 Crankshaft AssyWEIGHT, Balancer Cylinder Barrel Assy Honda GX340K1QA2 Cylinder Barrel AssyUSE from Engine Includes Items WSHAFT, Governor ARM BOLT, Drain PlugCylinder Head Assy Honda GX340K1QA2 Cylinder Head AssyGASKET, Cylinder Head CLIP, Valve GuideCOVER, Head TUBE, BreatherFAN Cover Assy Honda GX340K1QA2 FAN Cover AssyCLIP, Tube CLIP, Wire HarnessCOVER, FAN *R8* Bright RED ShroudFlywheel Assy Honda GX340K1QA2 Flywheel AssyFlywheel FAN, CoolingFuel Tank Assy Honda GX340K1QA2 Fueltank AssyJOINT, Fuel Tank RUBBER, Supporter 107MMTank Fuel *T34* Simpson Blue GASKET, Fuel Filler CAPIgnition Coil Assy Honda GX340K1QA2 Ignition Coil AssyGROMMET, Wire Coil ASSEMBLY, IgnitionWIRE, Stop Switch 430MM Carburetor Assy Honda GX340K1QA2 Carburetor AssyValve SET, Float Gasket SETFloat SET Includes Items W/%Honda GX340K1QA2 Carburetor Assy 25 + 9430520122 Muffler Assy Honda GX340K1QA2 Muffler AssyPROTECTOR, Muffler MufflerPROTECTOR, EX. Pipe PIPE, EXRecoil Starter Assy Honda GX340K1QA2 Recoil Starter AssyRATCHET, Starter PULLEY, Recoil StarterSPRING, Friction SPRING, Starter ReturnHonda GX340K1QA2 Control Assy Honda GX340K1QA2 Control Assy Labels Assy Honda GX340K1QA2 Labels AssyLABEL, Caution EmblemMARK, Choke External MARK, OIL Alert ETerms and Conditions of Sale Parts Page Multiquip INC

QP40TH specifications

The Multiquip QP40TH is a robust and reliable portable generator that stands out in the industry for its powerful performance and innovative features. Designed to cater to various applications, including construction sites, outdoor events, and emergency backup power, this generator delivers an impressive balance of power and portability.

One of the key features of the QP40TH is its 40 kW output capacity, which makes it suitable for a range of applications where high power is necessary. This generator is equipped with a three-phase generator system that ensures efficient energy distribution, enabling multiple tools and equipment to run simultaneously. With a fuel-efficient operation, the QP40TH keeps operational costs down while providing consistent power delivery.

The QP40TH utilizes a high-performance diesel engine that boasts reliability and durability, making it ideal for heavy-duty use. Its industrial-grade engine is designed to withstand the rigors of job sites, ensuring long-lasting performance under challenging conditions. Additionally, the generator features a robust frame and protective enclosure, allowing it to endure harsh environments while keeping internal components secure.

In terms of technology, the Multiquip QP40TH is equipped with advanced digital control systems that enhance user experience. The intuitive control panel provides easy access to essential information such as voltage output, frequency, and hour meter. This ease of monitoring ensures that users can manage their power needs effectively without complications.

Furthermore, the generator is designed with improved noise reduction technologies, enabling quieter operation compared to traditional models. This feature is particularly beneficial for events or locations where noise regulations must be adhered to. The QP40TH also includes a fuel tank that ensures extended run times, minimizing downtime for refueling and keeping projects on schedule.

Safety is a priority with the QP40TH, which is equipped with automatic shut-off features that protect the generator from overloads and low oil levels. These safety mechanisms provide peace of mind for users, safeguarding both the generator and connected equipment.

With its combination of power, efficiency, and reliability, the Multiquip QP40TH is a versatile generator that meets the demands of various applications. Its robust features and state-of-the-art technology make it a go-to choice for professionals in construction, events, and emergency services, ensuring that power needs are met with confidence.