Pentair CH installation manual Chemical Balance, Maintenance contd, Alkalinity High Low

Page 8

Maintenance (contd.)

8

CHEMICAL BALANCE

RULE: 7.4 to 7.6 is a desirable pH range. It is essential to maintain correct pH, see Table 2.

POOL AND SPA WATER

Your Pentair Pool Products pool heater was designed specifically for your spa or pool and will give you many years of trouble free service provided you keep your water chemistry in proper condition.

Three major items that can cause problems with your pool heater are improper pH, disinfectant residual, and total alkalinity. These items, if not kept properly balanced, can shorten the life of the heater and cause permanent damage.

CAUTION

Heat exchanger damage resulting from chemical imbalance is not covered by the warranty.

WHAT A DISINFECTANT DOES

Two pool guests you do not want are algae and bacteria. To get rid of them and make pool water sanitary for swimming - as well as to improve the water's taste, odor and clarity - some sort of disinfectant must be used.

Chlorine and bromine are universally approved by health authorities and are accepted disinfecting agents for bacteria control.

WHAT IS A DISINFECTANT

RESIDUAL?

When you add chlorine or bromine to the pool water, a portion of the disinfectant will be consumed in the process of destroying bacteria, algae and other oxidizable materials. The disinfectant remaining is called chlorine residual or bromine residual. You can determine the disinfectant residual of your pool water with a reliable test kit, available from your local pool supply store.

You must maintain a disinfectant residual level adequate enough to assure a continuous kill of bacteria or virus introduced into pool water by swimmers, through the air, from dust, rain or other sources.

It is wise to test pool water regularly. Never allow chlorine residual to drop below 0.6 ppm (parts per million). The minimum level for effective chlorine or bromine residual is 1.4 ppm.

pH - The term pH refers to the acid/alkaline balance of water expressed on a numerical scale from 0 to 14. A test kit for measuring pH balance of your pool water is available from your local pool supply store; see Table 1.

Table 1.

 

 

 

pH Chart

 

 

 

 

 

 

 

 

 

 

 

 

Strongly Acid

 

 

 

Neutral

 

Strongly Alkaline

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Muriatic Acid has a pH of about 0. Pure water is 7 (neutral). Weak Lye solution have a pH of 13-14.

If pH becomes too high (over alkaline), it has these effects:

1.Greatly lowers the ability of chlorine to destroy bacteria and algae.

2.Water becomes cloudy.

3.There is more danger of scale formation on the plaster or in the heat exchanger.

4.Filter elements may become blocked.

If pH is too low (over acid) the following conditions may occur:

1.Excessive eye burn or skin irritation.

2.Etching of the plaster.

3.Corrosion of metal fixtures in the filtration and recirculation system, which may create brown, blue, green, or sometimes almost black stains on the plaster.

4.Corrosion of copper in the heater, which may cause leaks.

5.If you have a sand and gravel filter, the alum used as a filter aid may dissolve and pass through the filter.

CAUTION: Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is 6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry.

RULE: Chemicals that are acid lower pH. Chemicals that are alkaline raise pH.

Table 2.

 

pH Control Chart

 

 

 

 

 

 

 

 

 

 

 

 

6.8

7.0

7.2

7.4

7.6

7.8

8.0

8.2

8.4

Add Soda, Ash or

Marginal

Ideal

Marginal

Add Acid

Sodium Bicarbonate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALKALINITY High - Low:

"Total alkalinity" is a measurement of the total amount of alkaline chemicals in the water, and control pH to a great degree. (It is not the same as pH which refers merely to the relative alkalinity/acidity balance.) Your pool water's total alkalinity should be 100 - 140 ppm to permit easier pH control.

A total alkalinity test is simple to perform with a reliable test kit. You will need to test about once a week and make proper adjustments until alkalinity is in the proper range. Then, test only once every month or so to be sure it is being maintained. See your local pool dealer for help in properly balancing the water chemistry.

P/N 472128

Rev. B 1-17-03

Image 8
Contents For additional free copies of this manual call 800 For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Table of Contents Code Requirements Important NoticesOperation contd Warranty InformationSafety Rules To Turn OFF GAS to Heater For Your Safety Read Before LightingLighting Instructions Dual Temperature Control System Operating ControlsMaintenance Instructions Energy Saving TipsSpring and Fall Operation Winter OperationMaintenance contd Chemical BalanceIf pH becomes too high over alkaline, it has these effects Alkalinity High LowInstallation Instructions SpecificationsPlumbing Installation contdPlumbing Connections Water Connections Insulating the High LimitsGAS Line Installations GAS ConnectionsRegulated Manifold Pressure Test Outdoor Installation only VentilationFront Stack Type Indoor Draft Hood KIT MiniMax CH Millivolt Wiring Diagram ElectricalTroubleshooting General Heater Short Cycling Rapid On and Off OperationMinimax CH Heater ALL Models MiniMax CH Parts List MiniMax CH Parts List, contd Rev. B MiniMax CH 150 IID Model Operation Operating InstructionsTo Turn OFF GAS to Appliance Safety Lockout Indicator Light Description Thermostat Knob StopperTroubleshooting Controls Heat HeatTroubleshooting Controls Regulated Manifold Pressure Test InstallationTransformer Wiring Instruction Electronic Ignition Wiring DiagramRemote Switch Dual Therm IID only Wire RemoteMinimax CH Heater 150 IID Model MiniMax CH Parts List 150 IID Model MiniMax CH Parts List 150 IID Model, contd Rev. B MiniMax CH Heaters Limited Warranty
Related manuals
Manual 36 pages 5.9 Kb

CH specifications

Pentair CH is a leading provider of advanced water treatment solutions, known for its innovative approaches in delivering high-quality water through cutting-edge technologies. Designed for both residential and commercial use, Pentair CH focuses on enhancing water quality and efficiency while promoting sustainability.

One of the standout features of Pentair CH products is their robust filtration systems. The company's advanced multi-stage filtration technology ensures that water is treated effectively, removing impurities and contaminants that can affect taste, odor, and safety. The filtration process often includes a combination of activated carbon, reverse osmosis, and UV sterilization, allowing for comprehensive protection against a wide range of pollutants.

Moreover, the Pentair CH technology is designed with user convenience in mind. Many models come equipped with smart features that allow users to monitor water quality and consumption through mobile apps. This connectivity not only helps in tracking usage patterns but also alerts users about maintenance needs, ensuring optimal performance and longevity of the system.

Energy efficiency is another hallmark of Pentair CH appliances. The company emphasizes the development of energy-saving designs that minimize electricity consumption while maximizing output. This commitment to environmental stewardship is reflected in its eco-friendly materials and manufacturing processes, making Pentair CH an excellent choice for those looking to reduce their ecological footprint.

Durability and reliability are key characteristics of Pentair CH products. The systems are engineered to withstand various water conditions and climatic changes, providing consistent performance over an extended lifespan. The use of high-grade materials and rigorous testing standards further underscores the brand’s commitment to quality.

Pentair CH also offers a range of customized solutions tailored to meet the specific needs of different customers. Whether addressing the requirements of a large commercial facility or a family home, the flexibility in product design ensures that users can find the perfect fit for their water treatment needs.

In conclusion, Pentair CH stands out in the water treatment industry with a comprehensive product lineup characterized by state-of-the-art filtration technologies, user-centric design, energy efficiency, durability, and flexibility. These features combine to provide users with safe, clean, and great-tasting water, reinforcing Pentair CH’s position as a trusted leader in water treatment solutions.