Pentair CH installation manual Installation Instructions, Specifications

Page 9

9

Installation Instructions

SPECIFICATIONS

IMPORTANT NOTICE: These installation instructions are designed for use by qualified personnel only, trained especially for installation of this type of heating equipment and related components. Some states require installation and repair by licensed personnel. If this applies in your state, be sure your contractor bears the appropriate license.

Outdoor installation - stackless

Model

"A" Dim "B" Dim

OFF

CH

 

150

17 7/8 in.

6½ in.

 

 

 

200

20 7/8 in.

9½ in.

 

 

 

250

23 7/8 in.

12½ in.

 

 

 

300

26 7/8 in.

15½ in.

 

 

 

350

29 7/8 in.

18½ in.

 

 

 

400

33 3/8 in.

22 3/8 in.

 

 

 

 

 

Table 3.

32

5

1

 

 

 

 

"B" DIM.

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

"A" DIM.

FRONT VIEW

13

7

 

 

8

 

 

21

1

4.875

2

 

SIDE VIEW

Outdoor installation - with vent kit

Model

"A" Dim

"B" Dim

"C" Dim

"D" Dim

 

 

 

 

 

150

17 7/8 in.

6½ in.

7¾ in.

39¾ in.

 

 

 

 

 

200

20 7/8 in.

9½ in.

10 in.

42¾ in.

 

 

 

 

 

250

23 7/8 in.

12½ in.

10 in.

42¾ in.

 

 

 

 

 

300

26 7/8 in.

15½ in.

10¼ in.

43¾ in.

 

 

 

 

 

350

29 7/8 in.

18½ in.

13 in.

47¾ in.

 

 

 

 

 

400

33 3/8 in.

22 3/8 in.

17 in.

51¾ in.

 

 

 

 

 

 

 

 

 

Table 4.

"C"

 

"E" DIM.

DIM.

 

 

"D"

 

 

DIM

 

 

 

OFF

CH

 

 

28"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1

 

 

 

 

"B" DIM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

"A" DIM.

 

 

 

 

 

 

 

 

 

 

211

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

"E" DIM.

 

 

 

4.875

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor installation - stack (USA only) Outdoor shelter installation (Canada)

Model

 

"A" Dim

"B" Dim

"C" Dim

"D" Dim

"E" Dim

 

 

 

 

 

 

 

150

 

17 7/8 in.

6½ in.

13 in.

52¾ in.

6 in.

 

 

 

 

 

 

 

200

 

20 7/8 in.

9½ in.

13 in.

53 7/8 in.

7 in.

 

 

 

 

 

 

 

250

 

23 7/8 in.

12½ in.

13 in.

53 7/8 in.

7 in.

 

 

 

 

 

 

 

300

 

26 7/8 in.

15½ in.

13 in.

55 in.

8 in.

 

 

 

 

 

 

 

350

 

29 7/8 in.

18½ in.

13 in.

56 in.

9 in.

 

 

 

 

 

 

 

400

 

33 3/8 in.

22 3/8 in.

17 in.

60¾ in.

10 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5.

Rev. B

1-17-03

 

 

 

 

"C"

 

 

 

DIM.

 

 

 

"D"

 

 

 

DIM

 

 

 

 

 

OFF

CH

 

 

 

28

 

 

 

107

 

 

 

8

 

 

 

GAS LINE

5

1

"B" DIM.

2

 

OPENING

 

 

"A" DIM.

13 78

4.875

2112

P/N 472128

Image 9
Contents For Your Safety Read Before Operating What to do if YOU Smell GASFor additional free copies of this manual call 800 Table of Contents Important Notices Code RequirementsWarranty Information Safety RulesOperation contd For Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF GAS to Heater Operating Controls Dual Temperature Control SystemEnergy Saving Tips Maintenance InstructionsSpring and Fall Operation Winter OperationChemical Balance Maintenance contdIf pH becomes too high over alkaline, it has these effects Alkalinity High LowSpecifications Installation InstructionsInstallation contd Plumbing ConnectionsPlumbing Insulating the High Limits Water ConnectionsGAS Connections GAS Line InstallationsRegulated Manifold Pressure Test Ventilation Outdoor Installation onlyFront Stack Type Indoor Draft Hood KIT Electrical MiniMax CH Millivolt Wiring DiagramHeater Short Cycling Rapid On and Off Operation Troubleshooting GeneralMinimax CH Heater ALL Models MiniMax CH Parts List MiniMax CH Parts List, contd Rev. B MiniMax CH 150 IID Model Operating Instructions To Turn OFF GAS to ApplianceOperation Safety Lockout Thermostat Knob Stopper Indicator Light DescriptionHeat Heat Troubleshooting ControlsTroubleshooting Controls Installation Transformer Wiring InstructionRegulated Manifold Pressure Test Diagram Electronic Ignition WiringWire Remote Remote Switch Dual Therm IID onlyMinimax CH Heater 150 IID Model MiniMax CH Parts List 150 IID Model MiniMax CH Parts List 150 IID Model, contd Rev. B MiniMax CH Heaters Limited Warranty
Related manuals
Manual 36 pages 5.9 Kb

CH specifications

Pentair CH is a leading provider of advanced water treatment solutions, known for its innovative approaches in delivering high-quality water through cutting-edge technologies. Designed for both residential and commercial use, Pentair CH focuses on enhancing water quality and efficiency while promoting sustainability.

One of the standout features of Pentair CH products is their robust filtration systems. The company's advanced multi-stage filtration technology ensures that water is treated effectively, removing impurities and contaminants that can affect taste, odor, and safety. The filtration process often includes a combination of activated carbon, reverse osmosis, and UV sterilization, allowing for comprehensive protection against a wide range of pollutants.

Moreover, the Pentair CH technology is designed with user convenience in mind. Many models come equipped with smart features that allow users to monitor water quality and consumption through mobile apps. This connectivity not only helps in tracking usage patterns but also alerts users about maintenance needs, ensuring optimal performance and longevity of the system.

Energy efficiency is another hallmark of Pentair CH appliances. The company emphasizes the development of energy-saving designs that minimize electricity consumption while maximizing output. This commitment to environmental stewardship is reflected in its eco-friendly materials and manufacturing processes, making Pentair CH an excellent choice for those looking to reduce their ecological footprint.

Durability and reliability are key characteristics of Pentair CH products. The systems are engineered to withstand various water conditions and climatic changes, providing consistent performance over an extended lifespan. The use of high-grade materials and rigorous testing standards further underscores the brand’s commitment to quality.

Pentair CH also offers a range of customized solutions tailored to meet the specific needs of different customers. Whether addressing the requirements of a large commercial facility or a family home, the flexibility in product design ensures that users can find the perfect fit for their water treatment needs.

In conclusion, Pentair CH stands out in the water treatment industry with a comprehensive product lineup characterized by state-of-the-art filtration technologies, user-centric design, energy efficiency, durability, and flexibility. These features combine to provide users with safe, clean, and great-tasting water, reinforcing Pentair CH’s position as a trusted leader in water treatment solutions.