Pentair MPRA, MPEA owner manual Pool Pump Suction Requirements

Page 5
Hazardous suction. Can trap hair or body parts, causing severe injury
or death.
Do not block suction.

Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10' (3m).

Allow use of short, direct suction pipe (To reduce friction losses).

Allow for gate valves in suction and discharge piping. Have adequate floor drainage to prevent flooding. Be protected from excess moisture.

Allow adequate access for servicing pump and piping.

Fire and burn hazard. Modern motors run at high temperatures. To reduce the risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for 20 minutes before trying to work on it.

NOTICE: When connecting threaded pipe directly to pump, use Teflon® tape or Plasto-Joint Stik® to seal connections. Do not use pipe dope; pipe dope causes cracking in some plas- tics and may damage components in piping system.

When connecting pipe to pump with union half, use Teflon® tape or Plasto-Joint Stik® between pipe and union adapter. Union collar to pump should be assembled dry and hand-tight.

NOTICE: Pump suction and discharge connections have molded in thread stops. DO NOT try to screw pipe in be- yond these stops.

Teflon® Taping Instructions:

Use only new or clean PVC pipe fittings.

Wrap male pipe threads with one to two layers of Teflon® tape. Cover entire threaded portion of pipe.

Do not overtighten or tighten past thread stop in pump port! If leaks occur, remove pipe, clean off old tape, rewrap with one to two additional layers of tape and remake the connection.

NOTICE: Support all piping connected with pump!

Piping:

Use at least 2" (51mm) pipe. Increase size if a long run is needed.

To avoid strains on the pump, support both suction and discharge pipes independently. Place these supports near the pump.

To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump.

To avoid airlocking, slope suction pipe slightly upward toward the pump.

NOTICE: To prevent flooding when removing pump for service, all flooded suction systems must have gate valves in suction and discharge pipes.

POOL PUMP SUCTION REQUIREMENTS

Pump suction is haz- ardous and can trap and

drown or disembowel bathers. Do not use or oper- ate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. Follow the guidelines below for a pump installation which minimizes risk to users of pools, spas, and hot tubs.

Entrapment Protection

The pump suction system must provide protection against the hazard of

suction entrapment or hair entrapment/entanglement.

Suction Outlet Covers

All suction outlet covers must be maintained. They must be replaced if cracked, broken, or missing.

See Page 6 for outlet cover certification requirements.

All suction outlets must have correctly installed, screw-fas- tened covers in place.

Suction Outlets Per Pump (Figure 3, Page 6)

Provide at least two hydraulically balanced main drains, with covers, as suction outlets for each circulating pump suction line. The centers of the main drains (suction outlets) on any one suction line must be at least three feet apart.

The system must be built so that it cannot operate with the pump drawing water from only one main drain (that is, there must be at least two main drains connected to the pump whenever it is running – see Figure 3, Page 6). However, if two main drains run into a single suction line, the single suction line may be equipped with a valve which will shut off both main drains from the pump (see Figure 3).

More than one pump can be connected to a single suc- tion line as long as the requirements above are met.

5

Image 5
Contents DYNA-PROTM Centrifugal Pumps With Integral Trap Technical Support Single Speed Models Read and Follow Safety InstructionsTable of Contents Pump mount must InstallationBefore pressure testing, make the following safety checks Pool Pump Suction Requirements Electrical Testing and CertificationWater Velocity FittingsTo Wire a Single Speed, Single Voltage Motor WiringTo Wire a Dual-Voltage Motor To Wire a Two-Speed MotorServ. to Motor Dist. in Ft. M Table I Recommended Circuit Breaker and Wiring DataOperation Routine MaintenancePriming Pump Storage/WinterizingPump should only be serviced by qualified personnel Pump ServiceDraining Pump Startup For Winterized EquipmentPump Dissasembly/Removing Old Seal Pump Reassembly/Installing New SealDisconnect power to pump motor Suction leaks/lost prime Troubleshooting GuideElectrical Clogged pipe/trap/impeller, worn impellerBox a MPEA6G-207L Page S771 Rev. B 2/8/08

MPRA, MPEA, MPE specifications

Pentair, a global leader in water solutions, has introduced a range of innovative products, including the MPRA, MPEA, and MPE. These advanced models are tailored for various applications, providing efficient and reliable performance in water management systems. Their design focuses on sustainability, ease of use, and operational efficiency, making them essential components for both residential and commercial purposes.

The Pentair MPRA (Multi-Phase Regulating Assembly) stands out for its versatility, allowing it to integrate seamlessly into existing setups. The MPRA is designed to manage pressure dynamics effectively, ensuring that water delivery remains stable even during peak usage periods. This model incorporates advanced pressure regulation technology, which minimizes water waste and promotes energy savings. With a robust construction, the MPRA is durable and can withstand harsh environmental conditions, making it ideal for low and high-demand applications.

The MPEA (Multi-Phase Energy Assembly) takes efficiency to the next level by combining energy management with advanced filtration capabilities. This model employs state-of-the-art technologies to optimize energy consumption while providing high-quality water. The MPEA features an innovative control system that monitors energy usage in real time, allowing users to adjust settings for maximum efficiency. Its smart design and easy integration with existing infrastructure make it a preferred choice for environmentally conscious consumers looking to reduce their carbon footprint.

The MPE (Multi-Phase Enhancement) model is specifically designed for enhancing water quality in various systems. This model utilizes cutting-edge filtration technology, which effectively removes contaminants from water while improving its taste and clarity. The MPE provides users with greater control over water quality parameters, facilitating healthier water usage in household and industrial applications. The compact size of the MPE makes it suitable for installations with limited space, without compromising performance.

In summary, Pentair's MPRA, MPEA, and MPE models reflect the company's commitment to innovation and sustainability in water management solutions. Equipped with advanced technologies, these products not only enhance efficiency but also contribute to a cleaner and safer environment. Their diverse applications make them suitable for a wide range of users, addressing the increasing demand for efficient water solutions in today’s world. Each model represents a step forward in Pentair's mission to deliver exceptional water quality while promoting responsible water use.