Johnson Controls F) SERIES Section XI Start UP Sheet, Air Conditioning and Heating Start-Up Sheet

Page 17

872678-UIM-C-0213

SECTION XI: START UP SHEET

Print Form

Air Conditioning and Heating Start-Up Sheet

Proper start-up is critical to customer comfort and equipment longevity

Reset Form

Start-Up Date

Technician Performing Start-Up

Installing Contractor Name

Owner Information

Name

 

 

 

Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

City

 

 

State or Province

 

 

 

 

 

Zip or Postal Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equipment Data

Upflow

Downflow

 

Horizontal Left

Horizontal Right

 

Indoor Unit Model #

 

 

 

 

 

Indoor Unit Serial #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Coil Model #

 

 

 

 

 

Indoor Coil Serial #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit Model #

 

 

 

 

 

Outdoor Unit Serial #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Filter, Thermostat, Accessories

Filter Type

Thermostat Type

Filter Size

 

Filter Location(s)

 

 

 

Other System Equipment and Accessories

Connections -- Per Installation Instructions and Local Codes

Unit is level

Supply plenum and return ducts are connected and sealed

 

Gas piping is connected (if applicable)

 

Condensate drain for indoor coil properly connected

Refrigerant piping complete and leak tested

Vent system is connected (if applicable)

Condensate drain for furnace (if applicable)

Electrical: Line Voltage

Indoor unit (volts AC)

Ground wire is connected

Outdoor unit (volts AC)

 

Overcurrent Protection Breaker / Fuses Amperes

 

 

 

Polarity is correct (120vac indoor units) black is L1 (hot), white is N (neutral)

Electrical: Low Voltage

Thermostat wiring complete

 

 

Heat anticipator

 

 

 

Heat anticipator is set to the recommended value listed in the Installation Instructions

recommended value

 

 

 

 

 

 

 

 

 

Low voltage values: "R" and "C" at Indoor unit control board (volts AC)

 

"R" and "C" Outdoor unit control board (volts AC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Set-Up

 

 

 

 

 

 

 

Heating Type

Electric Air Handler

Natural Gas

 

 

 

 

 

 

 

 

 

Inlet Gas Pressure (in. w.c.")

 

 

 

Manifold Gas Pressure (in. w.c.")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculated input in btuh - clock the gas meter (Nat Gas Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric Heat Kit Part # (if applicable)

 

 

KW installed

 

 

 

 

 

 

 

 

 

 

 

LP Gas (Requires LP Conversion Kit) LP Gas Conversion Kit Part # Used

LP Kit Installed By

Rated BTU/H (furnaces)

Venting (if applicable)

Intake Size

Exhaust Size

Venting system properly sized, within the limitations of the charts in the installation instructions.

# of 90 Degree Ells

 

# 0f 45 Degree Ells

 

Length

 

 

 

 

 

 

 

 

 

 

 

 

# of 90 Degree Ells

 

# 0f 45 Degree Ells

 

Length

 

 

 

 

 

 

 

 

 

 

 

Continued on next Page

Johnson Controls Unitary Products

17

Image 17
Contents List of Figures Section II SafetyList of Tables Section I GeneralADD-ON REPLACEMENT/RETROFIT Section III Unit InstallationLimitations LocationRoof Installation Ground InstallationPrecautions During Line Installation Liquid Line FILTER-DRIERPrecautions During Brazing Service Valve Precautions During Brazing of LinesSection VI Evacuation Section IV Orifice InstallationSection V TXV Installation Subcooling Charging Method TXV Indoor Section VII System ChargeSuperheat Charging Method Piston Indoor General Information & Grounding Field Connections Power WiringSection Viii Electrical Connections Power Wiring Field Connections Control WiringThermostat AC 1AID Models PSC Single Stage AIR Handler AIR ConditionerPSC Single Stage AIR AIR Handler Conditioner AC 1BSingle Stage PSC AIR Furnace Conditioner AC 5DSingle Stage AIR Conditioner AC 5ESingle Stage PSC Furnace Subcooling Charge Table is on the Unit Rating Plate MaintenanceSection IX Instructing the Owner Section X Wiring Diagram 412217 Yellow RED Air Conditioning and Heating Start-Up Sheet Section XI Start UP SheetCool Adjust

F) SERIES, 13 & 14.5 SEER - TCG(D, F), GCGD, TCJ(D specifications

Johnson Controls has long been a pioneer in HVAC technology, and their F-Series air conditioning units, specifically the 13 and 14.5 SEER models, have garnered attention for their efficiency and innovative features. The F-Series models TCG(D, F) and TCJ(D, GCGD) stand out in the market, offering a blend of advanced technology, energy efficiency, and user-friendly design.

One of the main features of the TCG and TCJ series is their high Seasonal Energy Efficiency Ratio (SEER), with options of 13 and 14.5 SEER. This high efficiency not only translates to lower energy bills for consumers but also promotes environmental sustainability by reducing carbon footprints. These units are designed to perform optimally in various climates, making them a versatile choice for homeowners and businesses alike.

Incorporating advanced refrigeration technology, the F-Series units utilize scroll compressors that are known for their reliability and efficiency. This type of compressor operates quietly and reduces the chances of breakdown, ensuring longevity and minimal maintenance. Additionally, the variable speed operation allows for better humidity control and comfort, adjusting to the specific cooling needs of the space.

Another key characteristic of Johnson Controls' F-Series is their advanced airflow design. The units are engineered to provide consistent and effective airflow, resulting in even temperature distribution throughout the space. With adjustable louvers, users can easily direct airflow to specific areas, enhancing comfort levels.

The TCG and TCJ models also feature enhanced filtration systems that significantly improve indoor air quality. These systems capture airborne particles and allergens, contributing to a healthier living environment. This focus on air quality is particularly beneficial for families with young children, the elderly, or individuals with respiratory issues.

For ease of use, Johnson Controls has integrated smart technology into their F-Series units. With Wi-Fi connectivity options, users can control their HVAC systems remotely through a smartphone app, allowing for convenient adjustments and energy management. This feature is increasingly important in today’s digital age, where home automation systems are becoming commonplace.

In summary, the Johnson Controls F-Series, particularly the 13 and 14.5 SEER models such as TCG(D, F) and TCJ(D, GCGD), showcase an impressive blend of energy efficiency, advanced technology, and user-centric features. With their reliable performance, superior air quality, and smart technology integration, these air conditioning units represent a solid investment for anyone looking to enhance their indoor comfort while being mindful of energy consumption.