Johnson Controls TCGD30 warranty Physical and Electrical Data, Service Valve Size

Page 2

415571-UTG-C-0309

Physical and Electrical Data

MODEL

 

TCGD30

TCGD36

TCGD42

TCGD48

TCGD60

TCGD30

TCGD36

TCGD42

TCGD48

TCGD60

 

S43S1

S43S1

S43S1

S43S1

S43S1

S44S1

S44S1

S44S1

S44S1

S44S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Supply Voltage

 

 

208-

230V, 3φ,

60Hz

 

 

460V, 3φ, 60Hz

 

Normal Voltage Range 1

 

 

187 to 252

 

 

 

 

432 to 532

 

 

Minimum Circuit Ampacity

11.4

12.3

16.3

15.5

23.9

9.4

7.1

8.0

7.9

13.5

Max. Overcurrent Device Amps 2

15

20

25

25

40

15

15

15

15

20

Min. Overcurrent Device Amps 3

15

15

20

20

25

15

15

15

15

15

Compressor Type

 

Recip

Recip

Recip

Recip

Scroll

Recip

Recip

Recip

Recip

Scroll

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Amps

 

Rated Load

8.1

8.6

11.8

11.2

17.9

6.6

4.5

5.2

5.1

9.6

 

 

 

 

 

 

 

 

 

 

 

 

 

Locked Rotor

63

68

88

88

120

30

34

44

44

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

 

No

No

No

No

No

No

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Amps

 

Rated Load

1.2

1.5

1.5

1.5

1.5

1.2

1.5

1.5

1.5

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Diameter Inches

 

 

17.5

22

22

22

22

17.5

22

22

22

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated HP

1/4

1/4

1/4

1/4

1/4

1/4

1/4

1/4

1/4

1/4

Fan Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal RPM

1100

850

850

850

850

1100

850

850

850

850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal CFM

2050

3200

2950

2950

3600

2050

3200

2950

2950

3600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face Area Sq. Ft.

9.6

13.07

14.16

14.16

18.68

9.6

13.07

14.16

14.16

18.68

Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows Deep

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fin / Inches

23

23

23

23

23

23

23

23

23

23

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Line Set OD

(Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

 

 

 

 

 

 

 

 

 

 

 

Vapor Line Set OD (Field Installed)

3/4

3/4

7/8

7/8

7/8

3/4

3/4

7/8

7/8

7/8

 

 

 

 

 

 

 

 

 

 

 

Unit Charge (Lbs. - Oz.) 4

3 - 14

4 - 9

4 - 5

4 - 9

5 - 6

3 - 14

4 - 9

4 - 5

4 - 9

5 - 6

Charge Per Foot, Oz.

0.62

0.62

0.67

0.67

0.67

0.62

0.62

0.67

0.67

0.67

 

 

 

 

 

 

 

 

 

 

 

Operating Weight Lbs.

131

145

173

173

195

131

145

173

173

195

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.

3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.

4.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. If line exceeds 25 feet, you may refer to publications software 036-68001-001 for proper line sizing.

All dimensions are in inches. They are subject to change with- out notice. Certified dimensions will be provided upon request.

 

 

C

 

 

 

 

 

 

 

 

 

 

Unit

 

Dimensions

 

Refrigerant Connection

 

 

 

 

 

(Inches)

 

Service Valve Size

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

A1

 

B

 

C

Liquid

Vapor

 

 

 

 

 

 

 

 

 

30

28

 

23-1/2

 

23-1/2

 

3/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

36

28

 

29

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8”

 

A

 

42

30

 

29

 

29

 

 

 

 

 

 

 

 

 

7/8”

 

 

 

48

30

 

29

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

32

 

33-5/8

 

33-5/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Including Fan Guard.

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Johnson Controls Unitary Products

Image 2
Contents Description WarrantyFeatures Service Valve Size Physical and Electrical DataOutdoor Unit ProceduresSystem Charge for Various Matched Systems Factory Charge, lbs-oz Indoor Coil3,4Seer AC with MA Cooling Capacity With Air Handler CoilsSens Seer AC with AHP / SHP / AHX / F*FPFurnace Cooling Unit Model CFM Range Rated NET MBH SEER1Net MBH Cooling Capacity With High Efficiency Motor FurnacesUnit Model Furnace Coil MODEL1 Cooling Rated Unit Furnace Coil Cooling Model MODEL1 Rated Seer EER CFMTypical Installation AccessoriesSound Power Ratings Typical Field WiringAIR Conditioner Model no TemperatureCooling Performance Data Indoor Coil Model no FC/MC/PC35 CondensingIndoor Coil Model no FC/MC/PC43 Condensing Indoor Coil Model no Indoor Coil Model no FC/MC/PC48 Condensing AHP/SHP60 AHX60 MA20D FC/MC60D FC/MC62D Johnson Controls Unitary Products York Drive Norman, OK

TCGD30 specifications

The Johnson Controls TCGD30 is a state-of-the-art temperature control device designed to enhance energy efficiency and optimize environmental comfort in commercial and industrial settings. This controller is part of Johnson Controls’ commitment to integrating technology with sustainable practices, making it a sought-after solution for modern HVAC systems.

One of the primary features of the TCGD30 is its advanced digital control capability. It employs sophisticated algorithms to maintain precise temperature control, ensuring that the desired environment is achieved while minimizing energy consumption. This precision is crucial in commercial applications where maintaining specific temperature ranges can directly impact product quality and employee comfort.

The TCGD30 utilizes a user-friendly interface that simplifies operation and programming. Its intuitive design allows facility managers to easily set parameters, access real-time data, and adjust settings without extensive training. This ease of use is further enhanced by the device's compatibility with various building management systems, allowing for seamless integration into existing infrastructures.

Another standout characteristic is the device’s support for a wide range of input and output options. This flexibility allows the TCGD30 to interface with different types of sensors, actuators, and HVAC equipment. Whether it’s for controlling dampers, fans, or heating and cooling units, the TCGD30 can accommodate diverse system configurations, making it suitable for various applications.

In terms of technology, the TCGD30 is equipped with robust communication protocols, including BACnet and Modbus, facilitating real-time data exchange with other system components. This capability not only enhances monitoring and control but also supports data-driven decision-making processes, empowering users to identify inefficiencies and optimize performance.

Energy efficiency is at the core of the TCGD30’s design. By leveraging its adaptive control strategies, the unit adjusts operation based on real-time conditions, effectively reducing energy wastage. This feature is especially beneficial in environments with variable occupancy levels or fluctuating thermal loads.

In conclusion, the Johnson Controls TCGD30 stands out as a versatile and efficient temperature control device. With its advanced digital control, user-friendly interface, flexible input/output options, and support for various communication protocols, it delivers enhanced performance in HVAC applications while promoting sustainability and energy savings. Its ability to integrate seamlessly into existing systems makes it an indispensable tool for maintaining optimal comfort and efficiency in any commercial or industrial setting.