COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

FURNACE

COIL

 

 

 

COOLING

 

 

MODEL

MODEL

MODEL1

W

RATED

Net MBH

SEER

EER

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

 

 

13 SEER HP WITH VARIABLE SPEED FURNACES2

 

 

 

 

T*(8,L)X*C16

FC/MC/PC48C

21

1600

48.0

34.4

13.30

11.00

 

T*(8,L)X*C20

FC/MC/PC48C

21

1660

48.0

34.4

13.20

11.00

 

T*9X*C16

FC/MC/PC48C

21

1565

48.0

34.8

13.10

11.00

 

T*9X*C20

FC/MC/PC48C

21

1615

48.0

34.4

13.20

11.00

 

T*9X*D20

FC/MC/PC48D

24

1635

48.0

34.8

13.20

11.00

TCGD48S4(3,4)S1

T*(8,L)X*C16

FC/PC60C

21

1605

48.0

34.6

13.30

11.00

T*(8,L)X*C20

FC/MC/PC60D

21

1595

48.0

34.8

13.30

11.00

 

 

T*9X*C16

FC/PC60C

21

1575

48.0

34.6

13.30

11.00

 

T*9X*C20

FC/PC60C

21

1625

47.0

34.6

13.40

11.00

 

T*9X*D20

FC/MC/PC60D

24

1490

47.5

33.8

13.20

11.00

 

T*9X*C16

FC/PC60C

21

1575

47.0

33.8

13.10

11.00

 

T*9X*C20

FC/PC60C

21

1625

47.0

33.8

13.10

11.00

 

T*(8,L)X*C16

FC/PC60C

21

1605

56.5

37.8

13.50

11.00

 

T*(8,L)X*C20

FC/MC/PC60D

21

1690

57.0

37.8

13.50

11.00

 

T*9X*C16

FC/PC60C

21

1575

56.0

37.8

13.30

11.00

 

T*9X*C20

FC/PC60C

21

1560

56.0

37.8

13.30

11.00

 

T*9X*D20

FC/MC/PC60D

24

1630

56.5

37.8

13.30

11.00

 

T*9X*C20

FC/MC/PC60D

21

1645

56.5

37.8

13.30

11.00

TCGD60S4(3,4)S1

T*(8,L)X*C20

FC/MC62D

21

1665

57.0

37.8

13.50

11.00

 

 

 

 

 

 

 

 

T*(8,L)X*C16

UC60C

21

1640

56.0

37.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

T*(8,L)X*C20

UC60D

21

1735

56.5

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

T*9X*C16

FC/PC60C

21

1575

56.0

37.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

T*9X*C20

FC/PC60C

21

1560

56.0

37.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

T*9X*D20

UC60D

24

1630

56.0

37.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

T*(8,L)X*C20

UC60D

21

1735

56.5

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

T*9X*C20

UC60D

21

1645

56.0

37.2

13.00

11.00

 

 

 

 

 

 

 

 

 

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2.Variable speed furnaces have B.O.D (Blower on Delay) standard.

Johnson Controls Unitary Products

7

Image 7
Contents Features WarrantyDescription Physical and Electrical Data Service Valve SizeFactory Charge, lbs-oz Indoor Coil3,4 ProceduresSystem Charge for Various Matched Systems Outdoor UnitSeer AC with AHP / SHP / AHX / F*FP Cooling Capacity With Air Handler CoilsSens Seer AC with MACooling Unit Model CFM Range Rated NET MBH SEER1 FurnaceUnit Model Furnace Coil MODEL1 Cooling Rated Cooling Capacity With High Efficiency Motor FurnacesNet MBH Seer EER CFM Unit Furnace Coil Cooling Model MODEL1 RatedTypical Field Wiring AccessoriesSound Power Ratings Typical InstallationIndoor Coil Model no FC/MC/PC35 Condensing TemperatureCooling Performance Data AIR Conditioner Model noIndoor Coil Model no FC/MC/PC43 Condensing Indoor Coil Model no Indoor Coil Model no FC/MC/PC48 Condensing AHP/SHP60 AHX60 MA20D FC/MC60D FC/MC62D Johnson Controls Unitary Products York Drive Norman, OK

TCGD30 specifications

The Johnson Controls TCGD30 is a state-of-the-art temperature control device designed to enhance energy efficiency and optimize environmental comfort in commercial and industrial settings. This controller is part of Johnson Controls’ commitment to integrating technology with sustainable practices, making it a sought-after solution for modern HVAC systems.

One of the primary features of the TCGD30 is its advanced digital control capability. It employs sophisticated algorithms to maintain precise temperature control, ensuring that the desired environment is achieved while minimizing energy consumption. This precision is crucial in commercial applications where maintaining specific temperature ranges can directly impact product quality and employee comfort.

The TCGD30 utilizes a user-friendly interface that simplifies operation and programming. Its intuitive design allows facility managers to easily set parameters, access real-time data, and adjust settings without extensive training. This ease of use is further enhanced by the device's compatibility with various building management systems, allowing for seamless integration into existing infrastructures.

Another standout characteristic is the device’s support for a wide range of input and output options. This flexibility allows the TCGD30 to interface with different types of sensors, actuators, and HVAC equipment. Whether it’s for controlling dampers, fans, or heating and cooling units, the TCGD30 can accommodate diverse system configurations, making it suitable for various applications.

In terms of technology, the TCGD30 is equipped with robust communication protocols, including BACnet and Modbus, facilitating real-time data exchange with other system components. This capability not only enhances monitoring and control but also supports data-driven decision-making processes, empowering users to identify inefficiencies and optimize performance.

Energy efficiency is at the core of the TCGD30’s design. By leveraging its adaptive control strategies, the unit adjusts operation based on real-time conditions, effectively reducing energy wastage. This feature is especially beneficial in environments with variable occupancy levels or fluctuating thermal loads.

In conclusion, the Johnson Controls TCGD30 stands out as a versatile and efficient temperature control device. With its advanced digital control, user-friendly interface, flexible input/output options, and support for various communication protocols, it delivers enhanced performance in HVAC applications while promoting sustainability and energy savings. Its ability to integrate seamlessly into existing systems makes it an indispensable tool for maintaining optimal comfort and efficiency in any commercial or industrial setting.