Johnson Controls TCGD18 THRU 60 Indoor Coil Model no FC/MC/PC43 Condensing, FC/MC/PC43 FC/MC/PC48

Page 15

359319-BTG-G-0509

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

TCGD36S41S1(H)

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC43

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

1000

 

 

 

 

1200

 

 

 

 

1400

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

34.7

36.1

35.2

37.4

37.3

33.8

35.5

34.8

37.0

37.5

32.9

34.9

34.4

36.6

37.6

65

S.C.

34.3

33.0

27.6

25.5

18.4

33.3

31.0

26.2

24.6

18.0

32.3

29.1

24.7

23.6

17.7

 

KW

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

1.9

2.0

1.9

2.0

2.0

 

T.C.

33.6

34.7

33.6

35.9

36.6

32.6

33.9

33.2

35.5

36.6

31.5

33.2

32.7

35.1

36.6

75

S.C.

33.3

32.5

27.5

25.6

18.6

32.1

30.6

25.8

24.5

18.0

31.0

28.7

24.2

23.3

17.5

 

KW

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.1

2.2

2.2

2.2

2.2

 

T.C.

32.4

33.2

32.0

34.4

35.8

31.3

32.3

31.5

34.1

35.7

30.2

31.5

31.0

33.7

35.5

85

S.C.

32.2

32.0

27.3

25.8

18.8

30.9

30.2

25.5

24.3

18.0

29.6

28.3

23.7

22.9

17.3

 

KW

2.4

2.4

2.4

2.4

2.4

2.4

2.4

2.4

2.4

2.4

2.3

2.4

2.4

2.4

2.4

 

T.C.

31.3

31.7

30.4

33.0

35.0

30.1

30.7

29.9

35.0

34.8

28.9

29.8

29.4

32.2

34.5

95

S.C.

31.1

31.5

27.2

26.0

19.0

29.7

29.7

25.2

24.9

18.0

28.3

27.9

23.2

22.5

17.1

 

KW

2.6

2.6

2.6

2.6

2.7

2.6

2.6

2.6

2.6

2.7

2.5

2.6

2.6

2.6

2.6

 

T.C.

27.9

28.8

27.2

29.8

32.5

27.0

27.8

26.6

29.4

32.2

26.0

26.9

25.9

29.0

31.9

105

S.C.

28.7

28.9

25.0

25.0

18.4

27.3

27.2

23.2

23.2

17.3

25.8

25.6

21.5

21.4

16.2

 

KW

2.8

2.8

2.8

2.8

2.9

2.8

2.8

2.8

2.8

2.9

2.7

2.8

2.7

2.8

2.9

 

T.C.

24.6

26.0

24.2

26.8

30.1

23.9

25.1

23.4

26.3

29.8

23.3

24.1

22.6

25.9

29.5

115

S.C.

26.3

26.3

22.8

24.1

17.8

24.9

24.8

21.3

22.2

16.6

23.5

23.3

19.8

20.3

15.4

 

KW

3.0

3.0

3.0

3.0

3.1

3.0

3.0

2.9

3.0

3.1

2.9

2.9

2.9

3.0

3.1

 

T.C.

21.3

23.2

21.1

23.7

27.6

20.9

22.3

20.2

23.2

27.3

20.5

21.3

19.3

22.7

27.0

125

S.C.

23.9

23.8

20.6

23.2

17.2

22.5

22.4

19.4

21.2

15.9

21.1

21.0

18.2

19.2

14.6

 

KW

3.2

3.2

3.2

3.2

3.4

3.2

3.2

3.1

3.2

3.3

3.1

3.1

3.1

3.2

3.3

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handlers

Coils

T.C.

S.C.

KW

FC/MC/PC43

1.00

1.00

1.00

FC/MC/PC48

1.00

1.00

1.00

HC42

1.00

1.00

1.00

UC48

1.00

1.00

1.00

AHP36

1.00

1.00

1.00

AHP42

1.00

1.00

1.00

AHX36

1.01

1.01

0.96

AHX42

1.01

1.02

0.94

AV*36

1.01

1.01

0.92

MV16C

FC/MC43C

1.01

1.02

0.92

MA12B

FC/MC43B

1.00

1.00

1.00

MV16C

FC/MC48C

1.01

1.02

0.92

MV20D

FC/MC48D

1.01

1.03

0.92

MA14D

FC/MC48D

1.00

1.00

1.00

MV12D

FC/MC48D

1.01

1.02

0.92

F5FP048

1.00

1.00

1.00

F6FP042

1.02

1.04

0.98

Furnaces

Coils

T.C.

S.C.

KW

T*(8,L)X*A12

FC/MC/PC37A

1.01

1.02

0.98

T*(8,L)X*B12

FC/MC/PC43B

1.01

1.02

0.98

T*(8,L)X*C16

FC/MC/PC43C

1.01

1.00

0.96

T*(8,L)X*C20

FC/MC/PC43C

1.02

1.03

0.96

T*9X*B12

FC/MC/PC43B

1.01

1.02

0.98

T*9X*C16

FC/MC/PC43C

1.01

1.02

0.98

T*9X*C20

FC/MC/PC43C

1.00

0.99

0.96

T*(8,L)X*C16

FC/MC/PC48C

1.02

1.02

0.97

T*(8,L)X*C20

FC/MC/PC48C

1.02

1.04

0.98

T*9X*C16

FC/MC/PC48C

1.02

1.04

0.98

Furnaces

Coils

T.C.

S.C.

KW

T*9X*C20

FC/MC/PC48C

1.01

1.01

0.97

T*9X*D20

FC/MC/PC48D

1.01

1.01

0.97

T*(8,L)X*C16

UC48C

0.98

1.00

0.93

T*(8,L)X*C20

UC48C

0.99

1.02

0.95

T*9X*C16

UC48C

0.99

1.00

0.97

T*9X*C20

UC48C

0.97

0.99

0.95

T*9X*D20

UC48D

0.97

0.99

0.95

T*(8,L)C*A12

FC/MC/PC37A

0.97

0.93

0.94

T*(8,L)C*B12

FC/MC/PC43B

1.01

1.01

0.98

(T*9C/T*9V)*B12

FC/MC/PC43B

1.01

1.01

0.98

T*(8,L)C*C16

FC/MC/PC43C

1.02

1.02

0.94

T*(8,L)C*C20

FC/MC/PC43C

1.02

1.02

0.93

(T*9C/T*9V)*C16

FC/MC/PC43C

1.01

1.02

0.97

(T*9C/T*9V)*C20

FC/MC/PC43C

1.02

1.02

0.95

T*(8,L)C*C16

FC/MC/PC48C

1.03

1.05

0.94

T*(8,L)C*C20

FC/MC/PC48C

1.03

1.05

0.93

(T*9C/T*9V)*C16

FC/MC/PC48C

1.03

1.04

0.95

(T*9C/T*9V)*C20

FC/MC/PC48C

1.03

1.06

0.97

(T*9C/T*9V)*D20

FC/MC/PC48D

1.03

1.05

0.94

T*(8,L)C*C16

HC42

1.02

1.02

0.94

T*(8,L)C*C20

HC42

1.02

1.03

0.93

(T*9C/T*9V)*C16

HC42

1.01

1.02

0.97

(T*9C/T*9V)*C20

HC42

1.02

1.02

0.95

T*(8,L)C*C16

UC48C

0.99

1.00

0.93

T*(8,L)C*C20

UC48C

0.99

1.00

0.92

(T*9C/T*9V)*C16

UC48C

0.99

1.00

0.94

(T*9C/T*9V)*C20

UC48C

1.00

1.03

0.97

(T*9C/T*9V)*D20

UC48D

0.99

1.01

0.94

Johnson Controls Unitary Products

15

Image 15
Contents Technical Guide Physical and Electrical Data ModelTCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 Procedures System Charge for Various Matched SystemsFootnotes Seer AC with MV Variable Speed Cooling Capacity With Air Handler CoilsSens Seer AC With MAUnit AIR Handler Cooling Model MODEL1 Rated NET MBH Seer EER CFMSeer AC with AHP / SHP / AHX / F*FP FC/MC/PC36 FC/MC/PC18Models Furnace Coil MODEL1 Cooling Rated Cooling Capacity With High Efficiency Motor FurnacesUC48D FC/MC/PC48CFC/MC/PC48D UC48C1210 34.6 24.8 13.50 11.50 LC*C20 Seer EER CFM Furnace Coil Cooling Models MODEL1 RatedSound Power Ratings Entering AIR TemperatureAIR Conditioner Model no Indoor Coil Model no FC/MC/PC18 CondensingMV12B FC/MC36B MA08B FC/MC35B FC/MC43B Indoor Coil Model no FC/MC/PC36 CondensingFC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 AHP30 AHX30 AHX36MV12B FC/MC35B MV16C FC/MC35C MA12B FC/MC43B FC/MC43C Indoor Coil Model no FC/MC/PC35 CondensingFC/MC/PC35 FC/MC/PC37 FC/MC/PC43 AHP30 AHP36 AHX30 AHX36Indoor Coil Model no FC/MC/PC43 Condensing FC/MC/PC43 FC/MC/PC48AHP36 AHP42 AHX36 AHX42 TCGD42S41S1H Indoor Coil Model no FC/MC/PC48 Condensing AHP/SHP48 AHP/SHP60 AHX48MV16C FC/MC48C MV20D FC/MC48D MA16C MA20D FC/MC60D FC60C MV20D FC/MC60D MA20D FC/MC62D AHP/SHP60 AHX60

TCGD18 THRU 60 specifications

The Johnson Controls TCGD18 THRU 60 is a sophisticated temperature control and monitoring solution designed for commercial and industrial applications. As energy efficiency and operational reliability become increasingly important, this device stands out for its cutting-edge features, advanced technologies, and robust characteristics.

One of the standout features of the TCGD18 THRU 60 is its precision temperature control. Utilizing advanced algorithms, it ensures accurate readings and adjustments, facilitating optimal conditions in various environments. This capability not only enhances comfort but also enables significant energy savings by reducing unnecessary heating or cooling, making it a formidable choice for businesses aiming to lower their operational costs.

The TCGD18 THRU 60 also supports a wide range of communication protocols, including BACnet and Modbus, ensuring seamless integration with existing building management systems. This interoperability is crucial for modern facilities that rely on interconnected devices to monitor and control their operations efficiently.

Another significant characteristic of this temperature control device is its user-friendly interface. Equipped with a clear display and intuitive controls, the TCGD18 THRU 60 makes it easy for operators to monitor and adjust settings as needed. The ability to customize the control parameters enhances its versatility across different applications, which is particularly beneficial for facilities with unique requirements.

With its robust build quality, the TCGD18 THRU 60 is designed for durability and longevity. It can withstand the rigors of industrial environments while maintaining consistent performance. Moreover, it is engineered to minimize downtime, as it features self-diagnostic capabilities that alert users to potential issues before they escalate.

In terms of energy efficiency, the TCGD18 THRU 60 incorporates innovative technologies that contribute to lower energy consumption. Features such as adaptive learning allow it to analyze usage patterns and make real-time adjustments to maintain desired conditions without unnecessary energy expenditure.

In conclusion, the Johnson Controls TCGD18 THRU 60 is a versatile, efficient, and reliable temperature control solution that integrates seamlessly into modern building systems. Its precision control, wide communication support, user-friendly interface, and robust design make it an ideal choice for a variety of commercial and industrial applications, ultimately delivering improved energy savings and enhanced operational efficiency. As demand for smarter, greener solutions grows, devices like the TCGD18 THRU 60 are paving the way toward more sustainable practices in temperature management.