Johnson Controls TCGD18 THRU 60 Unit AIR Handler, Cooling Model MODEL1 Rated NET MBH Seer EER CFM

Page 5

359319-BTG-G-0509

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

COIL

 

 

COOLING

 

 

MODEL

MODEL

 

W

MODEL1

RATED

NET MBH

SEER

EER

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

13 SEER AC WITH AHP / SHP / AHX / F*FP

 

 

 

 

AHP18

 

17

650

17.5

12.9

13.00

11.00

TCGD18S41S1(H)

AHX18

 

17

-

630

18.0

13.8

14.50

12.00

 

 

 

 

 

 

 

 

 

F4FP024

 

18

600

17.5

12.9

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

F6FP018

 

17

-

600

17.8

13.3

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

AHP30

 

17

795

24.0

16.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHX30

 

17

820

24.0

16.9

14.50

12.00

 

 

 

 

 

 

 

 

 

 

TCGD24S41S1(H)

AHX36

 

21

815

24.0

16.9

14.50

12.00

 

 

 

 

 

 

 

 

 

F4FP036

 

21.5

800

24.0

16.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

F6FP030

 

17

850

24.0

16.8

14.00

11.80

 

 

 

 

 

 

 

 

 

 

 

F6FP036

 

21

855

24.0

17.0

14.00

12.00

 

 

 

 

 

 

 

 

 

 

 

AHP30

 

17

1015

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

1040

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHX30

 

17

1025

29.4

22.2

14.00

11.75

TCGD30S41S1(H)

 

 

 

 

 

 

 

 

 

AHX36

 

21

1005

30.0

22.3

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

F4FP040

 

18

1050

29.0

21.0

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F6FP030

 

17

1035

29.2

21.6

13.50

11.40

 

 

 

 

 

 

 

 

 

 

 

F6FP036

 

21

980

29.4

21.4

14.00

12.00

 

 

 

 

 

 

 

 

 

 

 

AHP36

 

21

1235

35.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHP42

 

21

1255

35.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

TCGD36S41S1(H)

AHX36

 

21

1225

35.2

25.0

13.50

11.50

 

 

 

 

 

 

 

 

 

AHX42

 

21

1190

35.4

25.2

14.00

11.80

 

 

 

 

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1235

35.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F6FP042

 

21

1290

35.8

25.8

13.50

11.50

 

 

 

 

 

 

 

 

 

 

 

AHP42

 

21

1485

41.0

29.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHX42

 

21

1395

42.0

29.9

14.50

12.00

TCGD42S41S1(H)

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1455

41.0

29.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F6FP042

 

21

1455

42.0

30.1

14.00

11.75

 

 

 

 

 

 

 

 

 

 

 

F6FP048

 

24

1380

41.5

29.4

13.50

11.70

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP48

 

24

1675

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1600

48.0

35.0

13.50

11.00

 

 

 

 

 

 

 

 

 

 

TCGD48S41S1(H)

AHX48

 

24

1660

48.0

35.4

13.50

11.50

 

 

 

 

 

 

 

 

 

F5FP048

 

24

1600

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

F5FP060

 

24

1600

48.0

34.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F6FP048

 

24

1625

47.0

34.8

13.00

11.30

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1850

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

TCGD60S41S1

AHX60

 

24

1905

58.5

40.0

13.50

11.50

 

 

 

 

 

 

 

 

 

F5FP060

 

24

1900

57.0

38.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

F6FP060

 

24

1710

57.5

39.0

13.50

11.50

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

Johnson Controls Unitary Products

5

Image 5
Contents Technical Guide TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 Physical and Electrical DataModel Footnotes ProceduresSystem Charge for Various Matched Systems Sens Cooling Capacity With Air Handler CoilsSeer AC With MA Seer AC with MV Variable SpeedSeer AC with AHP / SHP / AHX / F*FP Unit AIR HandlerCooling Model MODEL1 Rated NET MBH Seer EER CFM FC/MC/PC36 FC/MC/PC18Models Furnace Coil MODEL1 Cooling Rated Cooling Capacity With High Efficiency Motor FurnacesFC/MC/PC48D FC/MC/PC48CUC48C UC48D1210 34.6 24.8 13.50 11.50 LC*C20 Seer EER CFM Furnace Coil Cooling Models MODEL1 RatedSound Power Ratings AIR Conditioner Model no TemperatureIndoor Coil Model no FC/MC/PC18 Condensing Entering AIRFC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 Indoor Coil Model no FC/MC/PC36 CondensingAHP30 AHX30 AHX36 MV12B FC/MC36B MA08B FC/MC35B FC/MC43BFC/MC/PC35 FC/MC/PC37 FC/MC/PC43 Indoor Coil Model no FC/MC/PC35 CondensingAHP30 AHP36 AHX30 AHX36 MV12B FC/MC35B MV16C FC/MC35C MA12B FC/MC43B FC/MC43CAHP36 AHP42 AHX36 AHX42 Indoor Coil Model no FC/MC/PC43 CondensingFC/MC/PC43 FC/MC/PC48 TCGD42S41S1H MV16C FC/MC48C MV20D FC/MC48D MA16C MA20D FC/MC60D FC60C Indoor Coil Model no FC/MC/PC48 CondensingAHP/SHP48 AHP/SHP60 AHX48 MV20D FC/MC60D MA20D FC/MC62D AHP/SHP60 AHX60

TCGD18 THRU 60 specifications

The Johnson Controls TCGD18 THRU 60 is a sophisticated temperature control and monitoring solution designed for commercial and industrial applications. As energy efficiency and operational reliability become increasingly important, this device stands out for its cutting-edge features, advanced technologies, and robust characteristics.

One of the standout features of the TCGD18 THRU 60 is its precision temperature control. Utilizing advanced algorithms, it ensures accurate readings and adjustments, facilitating optimal conditions in various environments. This capability not only enhances comfort but also enables significant energy savings by reducing unnecessary heating or cooling, making it a formidable choice for businesses aiming to lower their operational costs.

The TCGD18 THRU 60 also supports a wide range of communication protocols, including BACnet and Modbus, ensuring seamless integration with existing building management systems. This interoperability is crucial for modern facilities that rely on interconnected devices to monitor and control their operations efficiently.

Another significant characteristic of this temperature control device is its user-friendly interface. Equipped with a clear display and intuitive controls, the TCGD18 THRU 60 makes it easy for operators to monitor and adjust settings as needed. The ability to customize the control parameters enhances its versatility across different applications, which is particularly beneficial for facilities with unique requirements.

With its robust build quality, the TCGD18 THRU 60 is designed for durability and longevity. It can withstand the rigors of industrial environments while maintaining consistent performance. Moreover, it is engineered to minimize downtime, as it features self-diagnostic capabilities that alert users to potential issues before they escalate.

In terms of energy efficiency, the TCGD18 THRU 60 incorporates innovative technologies that contribute to lower energy consumption. Features such as adaptive learning allow it to analyze usage patterns and make real-time adjustments to maintain desired conditions without unnecessary energy expenditure.

In conclusion, the Johnson Controls TCGD18 THRU 60 is a versatile, efficient, and reliable temperature control solution that integrates seamlessly into modern building systems. Its precision control, wide communication support, user-friendly interface, and robust design make it an ideal choice for a variety of commercial and industrial applications, ultimately delivering improved energy savings and enhanced operational efficiency. As demand for smarter, greener solutions grows, devices like the TCGD18 THRU 60 are paving the way toward more sustainable practices in temperature management.