Johnson Controls ACPU024 THRU 060 manual MCA1

Page 21

279815-PTG-D-0408

TABLE 11: ACP024-060 ELECTRICAL DATA / ELECTRIC HEAT (CONTINUED)

 

 

Compressors

OD

Supply

 

 

 

 

 

 

Max Fuse2/

 

 

Fan

 

 

 

 

 

 

Size

 

Blower

 

Electric Heat Option

 

MCA1

Breaker3

Volt

 

(each)

 

Motors

 

 

(Tons)

 

 

Motor

 

 

 

 

(Amps)

Size

 

 

 

 

 

(each)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Amps)

 

 

RLA

LRA

 

MCC

FLA

FLA

Model

kW

Stages

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

-

41.2

50

 

208/230-1-60

25.0

150

 

39

2.3

7.6

2NH04501006

7.5 / 10

2

36.1 / 41.7

54.6

/ 61.6

60

/ 70

 

 

2NH04501506

11.3 / 15

2

54.2 / 62.5

77.2

/ 87.6

80

/ 90

 

 

 

 

 

 

 

 

2NH04502006

15 / 20

2

72.2 / 83.3

99.8 / 113.7

100

/ 125

 

 

 

 

 

 

 

 

2NH04502506

18.8 / 25

2

90.3 / 104.2

122.3

/ 139.7

125

/ 150

 

 

 

 

 

 

 

 

None

-

-

-

31.5

40

060

 

 

 

 

 

 

 

2NH04501025

7.5 / 10

1

20.8 / 24.1

35.6

/ 39.6

45

/ 45

208/230-3-60

17.3

123

 

27

2.3

7.6

2NH04501525

11.3 / 15

1

31.3 / 36.1

48.6

/ 54.6

50

/ 60

(5.0)

 

 

 

 

 

 

 

 

2NH04502025

15 / 20

2

41.7 / 48.1

61.6

/ 69.6

70

/ 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2NH04502525

18.8 / 25

2

52.1 / 60.1

74.7

/ 84.7

80

/ 90

 

 

 

 

 

 

 

 

None

-

-

-

15.6

20

 

460-3-60

8.4

70

 

13

1.3

3.8

2NH04501046

10

1

12

19.8

20

 

 

2NH04501546

15

1

18

27.3

30

 

 

 

 

 

 

 

 

2NH04502046

20

2

24.1

34.8

35

 

 

 

 

 

 

 

 

2NH04502546

25

2

30.1

42.3

45

1.Minimum Circuit Ampacity.

2.Maximum Over Current Protection per standard UL 1995.

3.Fuse or HACR circuit breaker size installed at factory or field installed.

Johnson Controls Unitary Products

21

Image 21
Contents Description Standard Features / BenefitsTable of Contents FIELD-INSTALLED Accessories Unit Cutaway Ratings ARI Physical Data75F 85F Cooling Capacities 2 TON ACP024Capacity1 Input Cooling Capacities 2-1/2 TON ACP030 Cooling Capacities 2-1/2 TON ACP030 Cooling Capacities 3 TON ACP036 Cooling Capacities 3 TON ACP036 Cooling Capacities 3-1/2 TON ACP042 Cooling Capacities 3-1/2 TON ACP042 Cooling Capacities 4 TON ACP048 Cooling Capacities 4 TON ACP048 Cooling Capacities 5 TON ACP060 CFM RPM Side and Bottom Supply AIR Blower PerformanceCFM Additional Static ResistanceTypical Field Wiring Diagram RLA LRA MCC FLA ACP024-060 Electrical Data / Electric HeatMCA1 Unit Dimensions Center of Gravity Clearances Unit WeightsTypical Applications Typical Slab on Ground InstallationRoof Curb Application Typical Wiring Diagram 208/230-1-60 Power Supply ACP Models Typical Wiring Diagram 208/230-3-60 Power Supply ACP Models Typical Wiring Diagram 460-3-60 Power Supply ACP Models Indoor Evaporator FAN Assembly Mechanical SpecificationsOutdoor Condenser FAN Assembly Unit CabinetUnit Operating Characteristics Electric Heating SectionElectrical Requirements PTG-D-0408 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK

ACPU024 THRU 060 specifications

Johnson Controls ACPU024 THRU 060 is a series of advanced air conditioning units designed to deliver efficiency, reliability, and optimal performance in various commercial and industrial settings. These air conditioning units are part of Johnson Controls' commitment to providing innovative solutions that meet the growing demands for energy efficiency and sustainable practices within the HVAC industry.

One of the standout features of the ACPU024 THRU 060 series is its exceptional energy efficiency. These units are equipped with high-efficiency scroll compressors and advanced coil designs that enhance heat exchange performance. This results in lower operating costs and reduced energy consumption, making the units a wise choice for businesses looking to minimize their environmental footprint while optimizing their operational expenses.

The ACPU models come with a wide range of capacities, from 024 to 060 tons, allowing for versatile application in settings ranging from offices to large commercial facilities. Additionally, they feature multiple airflow configurations, enabling customization to suit specific installation needs and enhance indoor air quality. This flexibility provides building managers and HVAC professionals with an ability to tailor the system to meet specific load requirements.

Technologically, the ACPU series incorporates smart controls and monitoring systems that give users real-time data on performance and energy usage. The user-friendly interface simplifies adjustments, scheduling, and diagnostics, making maintenance more straightforward and ensuring peak operation efficiency. The advanced controls are designed to integrate seamlessly with building management systems, promoting even higher levels of operational efficiency through automation.

Another important characteristic of the ACPU024 THRU 060 series is its design, tailored for durability and ease of installation. The units are constructed with weather-resistant materials, ensuring longevity even in challenging environments. Moreover, the modular design facilitates easy access to components for maintenance and repairs, reducing downtime and enhancing productivity.

In summary, Johnson Controls ACPU024 THRU 060 series is a leading choice for those seeking robust, energy-efficient air conditioning solutions. With its advanced technology, flexibility in application, and focus on sustainability, it stands out as a reliable choice for enhancing indoor comfort while also meeting regulatory energy standards.