GE QS2800V, QS1800V manual Motor Wiring Single-Phase Motors Important

Page 16

3.6Motor Wiring

3.6.1Single-Phase Motors - IMPORTANT!

Single phase three-wire motors require the use of a special controller includ- ed in a separate enclosure with each motor. The controller enclosure is not attached to the motor. Operation of motors without the controller or using the incorrect controller can result in failure of the motor and voids warranty.

The controller is mounted in a NEMA 4X enclosure and suitable for indoor or outdoor applications within temperatures of 14°F (-10°C) to 122°F (50°C).

The controller should never be mounted in direct sunlight or high-temperature locations as this will cause shortened capacitor life and unnecessary tripping of the overload protector.

The controller enclosure is designed for vertical upright mounting only. Mounting in other positions will affect its operation.

The controller must be electrically wired to the motor using minimum 8 AWG for 5 horsepower motors and 10 AWG for 3 horsepower motors.

Figure 3.5

Two Sources of Power to

the Single-Phase Controller

The controller must be supplied with two sources of power. The control circuit (motor starter coil) must be electrically wired with 110 VAC-50 Hz or 120 VAC- 60 Hz voltage. The power circuit must be electrically wired with single-phase to match the motor label.

10

Image 16
Contents Osmonics TONKAFLO Pumps QSV Series Page Operation and Maintenance Manual Flow-Cooled Motor and Liquid End Tonkaflo Service Policy 10.0List of Figures Page Introduction Tonkaflo Specifications D e l Q S 2 8 2 5 V 5Pump Label Junction Box Motor Label Liquid End Motor ModulePump Performance Summary 2875 rpm420 280Cast iron or Noryl plastic-covered carbon Steel stator ends, bronze filter check valveNitrile and neoprene rubber seals Olefin epoxy-pottedPump Installation Page Page Victaulic Gasket Victaulic Clamp Discharge Screen InstallationPump Water Level Discharge InletMotor Wiring Single-Phase Motors Important Two Sources of Power to Single-Phase ControllerChanging Motor Rotation StepsRolling the Leads to Balance Current Draw Page Do not Run pump Dry or Without Sufficient Pump OperationDo not deadhead pump General Troubleshooting Throttled at the inlet. CheckInlet strainer/filter plugged Ing may draw air intoTo lift or pull fluid from a Ating within the flow rangeNot operational Motor wired improperlyDraw Tory for liquids other than Voltage, then at a potentialPump/motor vibrates Pump leaksField Maintenance Liquid End Removal and InstallationSteps Page Tonkaflo Pump Return Goods Authorization RGA Procedure Dimensional Drawing QS1800V QS2800V SeriesParts Schematic Replacement PartsParts Schematic Part Description QS1800V QS2800V Part NumberClearwater Drive Minnetonka, MN GE Infrastructure Water & Process TechnologiesUSA Warranty Pump Model Number Pump Serial NumberPage North American Sales Euro/Africa Sales Asia/Pacific Sales

QS1800V, QS2800V specifications

The GE QS1800V and QS2800V are part of General Electric's advanced line of gas turbine technology, designed for efficiency and reliability in power generation. These turbines are primarily utilized in industrial and utility-scale applications, providing robust solutions to meet growing energy demands.

The QS1800V boasts a power generation capacity of approximately 1800 kW, while the QS2800V steps up to about 2800 kW. Both of these models are engineered for flexible operation, allowing them to integrate seamlessly into varying grid conditions and supporting fluctuating energy requirements.

One of the standout features of these turbines is their state-of-the-art aerodynamic design, which enhances efficiency by optimizing airflow through the turbine stages. This design leads to a significant reduction in fuel consumption and emissions, aligning with the increasing global need for cleaner energy solutions.

The combustion technology employed in the QS series features low-NOx (nitrogen oxides) burners, which contribute to minimized environmental impact by significantly reducing harmful emissions without compromising performance. This makes the QS1800V and QS2800V ideal for both regulatory compliance and consumers looking for sustainable power options.

In terms of reliability, GE has incorporated advanced materials and manufacturing processes in the construction of the QS series turbines. The use of high-performance alloys and coatings increases the lifespan of critical components, ensuring reduced downtime for maintenance and repairs. The turbine’s modular design further enhances maintainability, allowing for easier access to components and streamlined servicing.

The control systems for the QS1800V and QS2800V turbines feature sophisticated automation technology that ensures optimal operation under various load conditions. Advanced sensors and monitoring systems provide real-time data, enabling predictive maintenance strategies that can help operators avoid costly outages.

Furthermore, the QS series is designed for adaptability, making it compatible with renewable energy sources. This capability allows for hybrid systems that can integrate wind or solar power, providing a comprehensive solution for modern energy demands.

In summary, the GE QS1800V and QS2800V are advanced gas turbines that combine efficiency, sustainability, and reliability, making them a top choice for power generation in various applications. They stand out in their class with technologies that not only meet current energy needs but also pave the way for future advancements in cleaner and more efficient power generation.