Operating Instructions Safety Instructions

Window Installation Instructions.

Install the Security Bracket and the Foam Top Window Gasket

8

 

Attach the security bracket with a type B screw.

 

Cut the foam top window gasket to the

A

B

 

 

 

 

 

window width.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stuff the foam between the glass and the

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

window to prevent air and insects from getting

 

 

 

 

 

 

 

 

into the room.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tips Installation Instructions

Install the Air Conditioner in the Case

9

 

Slide the air conditioner into the case.

A

Reinstall the 2 screws removed earlier on

 

 

 

each side of the case.

 

 

Place the bottom inner case gasket between the

 

B

 

 

bottom of the air conditioner and the inside

 

 

 

 

bottom of the case. Fold up the ends on both

 

 

sides and push them in.

C

Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place.

Consumer Support Troubleshooting

Guide the lever carefully through the grille as you push it in.

Bottom inner

Front of aircase gasket conditioner.

 

Secure the front grille to the case by replacing

D

 

the screw removed in Step 3A. If a screw was

 

 

not removed in Step 3A, secure the grille to

 

the case with a Type D screw.

 

The installation is now complete.

14

Image 14
Contents 49-7405-3 12-00 JR Write the model and serial numbers here Model # Serial #Consumer Support Troubleshooting Tips Installation Instructions Operating InstructionsTroubleshooting Tips Consumer Support USE of Extension Cords -115-Volt models onlyRemote Control ConsumerVent Control Cool ModeFAN Mode Air Direction Up and DownCooling Descriptions Mode ControlsTemp Controls For Normal Cooling-SelectHIGH Cool or MEDAir Direction Up and Down on some models Instructions TroubleshootingAir Direction Side-to-Side Instructions OperatingInstallation Instructions Operating Care and cleaning of the air conditionerTroubleshooting Tips Preparing to install the air conditioner Read these instructions completely and carefullyWindow Installation Instructions Remove the Front Grille, if attached Window RequirementsStorm Window Requirements Prepare the Case Operating InstructionsRemove the Air Conditioner From the Case Prepare the WindowInstall the Case in the Window Install the Air Conditioner in the Case Consumer Support TroubleshootingInstall the Security Bracket and the Foam Top Window Gasket Finish the Wall Opening Through the Wall Installation Instructions-OptionalInstructions Operating Instructions Installation Normal Operating Sounds Before you call for service…Consumer Support We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration What Is Not Covered Air Conditioner WarrantySafety Instructions Operating Instructions We Will ReplaceConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio
Related manuals
Manual 20 pages 1.44 Kb Manual 40 pages 7.34 Kb

ASV14, ASV12, AST10, AST18, AST12 specifications

General Electric (GE) has made a significant impact in the industrial automation market with its range of programmable logic controllers (PLCs) tailored for various applications. Among these models, the ASQ24, ASN24, ASL24, ASV24, and ASW24 stand out for their unique features, technologies, and characteristics that cater to diverse operational needs.

The ASQ24 model is known for its versatility in handling complex automation tasks. This PLC integrates advanced communication capabilities, allowing seamless connectivity with other devices in an industrial network. It features robust processing power and enhanced memory capacity, enabling it to execute sophisticated algorithms and manage extensive I/O operations efficiently.

Moving to the ASN24, this model is specifically designed for applications requiring high-speed data processing and real-time control. Equipped with specialized functions to manage motion control and automation seamlessly, the ASN24 excels in environments with stringent timing requirements. Its compatibility with various communication protocols ensures it can interface easily with existing systems, enhancing interoperability within manufacturing operations.

The ASL24 model focuses on safety and reliability. Complying with international safety standards, the ASL24 comes equipped with built-in safety features designed to mitigate risks in industrial operations. This model also allows for easy diagnostics and system monitoring, making maintenance straightforward. This PLC is ideal for applications where equipment safety and operational integrity are paramount.

The ASV24 enhances visualization and user interaction with robotic applications. It incorporates advanced human-machine interface (HMI) technology, allowing operators to monitor and control processes intuitively. The ASV24 is designed to facilitate data visualization and analytics, providing insights into operational efficiency and performance metrics.

Lastly, the ASW24 is tailored for wireless applications, making it suitable for operations in remote or mobile environments. This model supports wireless communication networks, permitting real-time monitoring and control without traditional cabling constraints. The ASW24 is perfect for scenarios where flexibility and ease of deployment are prioritized.

In summary, the GE ASQ24, ASN24, ASL24, ASV24, and ASW24 PLCs represent a comprehensive suite of automation solutions. With their unique features, such as enhanced safety, high-speed processing, intuitive visualization, and wireless capabilities, these models cater to the diverse needs of modern industrial operations, making them essential tools for optimizing productivity and efficiency across various sectors.