GE AGW18, AGH18 owner manual Safety Precautions, Consumer Support Troubleshooting Tips

Page 2

Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS

Installation Instructions Operating Instructions

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

HOW TO CONNECT ELECTRICITY

Consumer Support Troubleshooting Tips

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered,

it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

2

Image 2
Contents Air Conditioners Write the model and serial numbers here Model # Serial #Safety Precautions Consumer Support Troubleshooting TipsInstallation Instructions Ge.comRemote Control Instructions Operating Instructions Safety InstructionsPower Outage Recovery Feature InstallationSafety Outdoor Coils Care and cleaning of the air conditionerGrille and Case Air FilterTools YOU will Need Before YOU BeginElectrical Requirements Installation Instructions Parts IncludedWindow Requirements Storm Window RequirementsRemove the AIR Conditioner from the Case Prepare the Window and the CaseInstall the Case in the Window Prepare the WindowInstall the AIR Conditioner in the Case Install the AIR Conditioner in the CaseTroubleshooting Tips Normal Operating Sounds We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Will Replace GE Air Conditioner WarrantyWhat Is Not Covered Consumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design StudioAcondicionadores de Aire ¡ADVERTENCIA Operación InstalaciónApoyo al consumidor Solucionar problemasOperación Apoyo al Instalación ProblemasAcerca de los controles en el acondicionador de aire Función de recuperación de pérdida de energíaControl de la ventilación Modo Cool FríoModo de FAN Ventilador Dirección del aire-de lado a ladoPrecaución no Opere el Instalación Apoyo al consumidor Solucionar problemasCuidado y limpieza del acondicionador de aire SeguridadAntes DE Iniciar Requisitos EléctricosHerramientas QUE Necesitará Partes IncluidasRequisitos Para LA Ventana Requisitos DE UNA Ventana DE TormentasPrepare LA Ventana Y LA Caja Retire EL Acondicionador DE Aire DE LA CajaPrepare LA Ventana Instale LA Caja EN LA VentanaLA Ventana Instale EL Acondicionador DE Aire EN LA CajaSolucionar problemas Seguridad Operación InstalaciónLa función de Se acumula aguaEn la bandeja No está funcionandoSonidos de operación normales Notas GE reemplazará Garantía de su acondicionador de aire de GESeguridad Operación Lo que no está cubiertoGarantías ampliadas Apoyo al consumidor Página Web de GE AppliancesSolicite una reparación Piezas y accesorios

AGH18, AGW18 specifications

The GE AGH18 and AGW18 are high-efficiency air conditioning systems that represent the latest advancements in HVAC technology. Designed for both residential and commercial applications, these models from GE combine performance, reliability, and energy efficiency, making them ideal for diverse climate conditions.

One of the standout features of the GE AGH18 and AGW18 is their exceptional energy efficiency ratings. These systems are engineered with an advanced inverter technology that allows them to adjust the compressor speed based on the cooling demand. This not only helps maintain a more consistent indoor temperature but also reduces energy consumption, resulting in significant cost savings on utility bills.

The GE AGH18 and AGW18 are equipped with smart technology that offers enhanced user control and convenience. With Wi-Fi connectivity, users can manage their air conditioning settings remotely through a smartphone app. This feature is particularly beneficial for homeowners who wish to regulate their HVAC system while away from home, ensuring that the indoor environment is comfortable upon their return.

Another notable characteristic of these models is their whisper-quiet operation. The engineers at GE have prioritized noise reduction, resulting in systems that operate at remarkably low sound levels. This makes them suitable for installation in bedrooms, offices, and other noise-sensitive environments where peace and quiet are essential.

Durability and reliability are also critical elements of the GE AGH18 and AGW18 units. Constructed with high-quality materials and designed to withstand harsh weather conditions, these air conditioning systems ensure long-lasting performance. The use of corrosion-resistant components further enhances their reliability, particularly in coastal areas where salt and humidity can take a toll on HVAC equipment.

Additionally, both models feature advanced filtration systems that improve indoor air quality by capturing dust, allergens, and other pollutants. This is particularly important in today’s environment, where air quality is a growing concern.

In summary, the GE AGH18 and AGW18 air conditioning systems deliver a powerful combination of energy efficiency, user-friendly technology, quiet operation, durability, and improved air quality. With these impressive features, both models stand out in the competitive HVAC market, catering to the needs of modern consumers who seek comfort, efficiency, and convenience in their cooling solutions.