GE AZ28E12E dimensions Wall Case Dimensions, Electrical Wiring, RAB71 Wall Sleeve, Grille Options

Page 1

GE Appliances

AZ28E12E – GE Zoneline® Deluxe Series Cooling and Electric Heat Unit

Wall Case Dimensions

Maximum Cord Extension (in inches)

Electrical Wiring

All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.

A

C

B

RAB71 Wall Sleeve

Heavy-gauge galvanized steel, with insulation. A – 42 B – 13-3/4 C – 16"

RAB77 Wall Sleeve

Molded SMC fiberglass-reinforced polyester compound. A – 42-1/8 B– 13-7/8 C – 16-1/4

265 Volt Sub-Base Connected Units

21

58

Wall Opening Di m ensions

Add 1/4" to A and C dimensions for all cut-out size. RAB71 16-1/4 Min. H x 42-1/4 Min. W

RAB71 available in 16 24 28 and 31 depths RAB77 16-1/2 Min. H x 42-3/8 Min. W

Note: Aluminum wiring may pose special problems – consult a qualified electrician.

Grille Options

Stamped Aluminum Grille – RAG60

Exterior Architectural Louvers Durable Polycarbonate:

RAG61 or RAG64 (Beige)

RAG63 or RAG66

(Bittersweet)

RAG62 or RAG65 (Maple)

RAG67 (Extruded

Aluminum)

Retrofit Kits:

RAK901L – Wall Case Insulation for use with heat pumps. RAK40 – Deflector Kit to adapt chassis for use with existing exterior architectural louvered grilles.

Ducted Applications

2800 and 3800 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adaptor is applied to top of case over air discharge/ RAK601 Duct Extension is applied to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum recommended distance of 15 feet.

Electrical Connection

 

 

 

 

Min. Circuit

 

Power

Electric

Electric

Protection

Sub-Base

Connection Kit

Heater Watts

Heat Amps

(Amps)

RAK204E15

RAK5172

2,550

10.3

15

RAK204E20

RAK5202

3,450

13.7

20

RAK204E30

RAK5302

5,000

19.6

30

Specification Created 9/04

230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers Design Data Manual for electrical connection information including use of sub-base for direct connected units. Installation must comply with local electrical codes and regulations.

Power Connection kits required on all Zoneline chassis.

For answers to your Monogram ® GE Profileor GE® appliance questions, visit our website at ge .com or call GE Answer Center® service, 800.626.2000.

390515

Image 1
Contents Electrical Wiring Wall Case DimensionsSpecification Created 9/04 Power Connection kits required on all Zoneline chassisFeatures and Benefits