Specifications

Charger Specifications

Without a battery temperature

Three settings with the following

sensor

temperature values:

 

Cool 50 °F (10 °C)

 

Warm 77 °F (25 °C)

 

Hot 104 °F (40 °C)

 

The default value for this setting is

 

Hot, and it can only be changed by a

 

dealer, factory, or service centre.

 

 

With a battery temperature

The temperature compensation

sensor

coefficients on a 12 volt battery are as

 

follows:

 

Flooded: 27 mV × (25 °C – BTS °C)

 

Gel: 27 mV × (25 °C – BTS °C)

 

AGM: 21 mV × (25 °C – BTS °C)

 

 

Equalization cycle

Yes, manual via SCP

 

 

Number of independent battery

1

banks

 

 

 

Battery bank size settings

50 – 2000 Ahr

 

 

Battery type settings

Flooded, AGM, Gel, Custom

 

 

Power factor corrected

Yes

charging

 

 

 

Input power factor at full

> 0.95

charge rate

 

 

 

Charger Specifications

AC input voltage

85

– 135 VAC

 

 

 

AC input frequency

60

Hz nominal, 55 – 65 Hz operating

 

range

 

 

Minimum battery voltage

5.0 VDC

 

 

Maximum DC output voltage

16.0 VDC

 

 

Peak charger efficiency

84%

 

 

Maximum charge current

150 A

 

 

Maximum charge current

150 A

 

 

 

62

Freedom SW 3000 Owner’s Guide

Page 76
Image 76