Configuration

You can adjust the power share settings as follows:

Range of values

Increment

Default

 

 

 

5 to 30 amps

5 amps

30 amps

 

 

 

When to use Set the Power Share setting to match the AC input breaker. Use this setting when connecting to an AC source. If using multiple AC sources via an AC transfer switch, adjust this setting to the smaller AC breaker size.

Outcome Setting the value higher than the AC source’s external breaker could cause the external breaker to trip.

Equalize

Configurable setting This setting lets you enable or disable charger equalization, if the battery type is flooded (or wet). Equalization can be turned on (enabled) or off (disabled). The default setting for equalize is Off.

Equalize[Off]

When to use Review the section, “Operating in Equalization Mode” on page 10 before adjusting this setting. This menu item is displayed if the battery type allows equalization.

In the Freedom SW 3000 home menu, highlight Equalize, as shown in Figure 21.

[Enabled]

[10.0A]

[On]

[Flooded]

Figure 21 Equalize On

When you select On, the equalization confirmation warning appears, as shown in Figure 22.

34

Freedom SW 3000 Owner’s Guide

Page 48
Image 48
Xantrex Technology SW 3000 user service Equalize, Range of values